University of Virginia Health System
Charlottesville, Virginia, 22908, United States
NCT Number: NCT02442973
Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures. Epidural analgesia is the mainstay procedure for the management of labor pain. The precise placement of a needle or catheter in proximity to landmarks of the spinal bone anatomy is required for the procedure to succeed. The current standard of care is called the 'blind approach' (i.e. without medical imaging) and involves a physician manually palpating a patient's back to locate spinal bone landmarks. The needle is then inserted with respect to the location of the landmarks and inserted until a loss-of-resistance is manually detected. This approach, while most common, has been associated with success rates as low as 68% in obese patients (2).
Alternative methods have been investigated for this problem, including ultrasound (US) guidance, which offers real-time imaging. Several studies have demonstrated ultrasound's efficacy for spinal anesthesia (1-6). However, standard US systems are engineered to image soft tissue rather than bone structures, with the consequence that bone is imaged poorly. US images are often degraded by a number of noise sources including speckle noise, reverberations and off-axis scattering, particularly when bone is present, making visualization of bone anatomy features difficult. Moreover, arranging access to ultrasound for the purpose of spinal anesthesia alone is cumbersome. Thus, the efficacy of guided spinal anesthesia and diagnostic procedures using standard ultrasound systems is limited and the benefits that it offers are heavily dependent on the user's familiarity and skill with ultrasonography (4).
Recently, new medical imaging technologies have been developed at Rivanna Medical, LLC to address the significant clinical need for technological advances that improve the placement of spinal anesthesia, epidural analgesia and other diagnostic procedures. The Accuro is a pocket-sized and battery operated ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone imaging including 3D navigation of the lumbar spine. The device is a single self-contained unit consisting of an ultrasound system, ultrasound probe, and rotatable touchscreen display. The instrument enables a SpineView3D™ technology to facilitate spinal anesthesia guidance with real-time 3D navigation of the lumbar spine anatomy.
SpineView3D™ technology facilitates image interpretation of individual 2D lumbar spine scans by automating spinal bone landmark detection and depth measurements and providing a real-time assessment of scan plane orientation in 3D. SpineView3D™ makes image interpretation and measurements of the lumbar spine anatomy simple, quick, and easy. Real-time 2D scans from either SpineView3D™ or general-purpose bone presets are formed using patent-pending BoneEnhance+™ technology. The BoneEnhance+™ technology provides images of bone anatomy at greater bone-to-tissue contrast compared with conventional ultrasound image reconstructions.
Looking for future studies?
Notify Me18 year–40 year
Female
Observational
Charlottesville, Virginia, 22908, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Patients between the ages of 18 and 40 presenting for delivery and planning epidural anesthesia
Exclusion criteria
Patients with known spinal deformities allergies to ultrasound gel
Standard practice group
Other names: CG
SpineView3D™ anatomical "scouting" approach
Other names: UG
subject will be scanned with 'Accuro SpineView3D
Other names: scan
Time frame: 1 day
defined as successful epidural administration on the first needle insertion attempt.
University of Virginia
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07725549
Birth Weight, Body Weight
Purwodadi Grobogan, Central Java, Indonesia
View Trial DetailsNCT02447159
Behavior, Blood-Borne Infections
Eket, Akwa Ibom State, Nigeria
View Trial DetailsNCT07072507
Birth, Birth Memory
Bursa, Turkey (Türkiye)
View Trial DetailsNCT04446611
Acquired Immunodeficiency Syndrome, Antenatal Care
East London, Eastern Cape, South Africa
View Trial Details