Hand Position for Stylet Removal During Tracheal Intubation

Investigators compared the tube movement between two situations; the one was that the practitioner's hand holding the tracheal tube was placed in the air, and the other was that the hand was placed on the manikin's cheek, while two residents took the roles of the practitioner and the assistant in tracheal intubation with a stylet for a manikin.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Sex eligibility

All sexes

Study type

Observational

Primary location

Seoul Metropolitan Government Seoul National University Boramae Medical Center

Seoul, 07061, South Korea

About this study

Residents who accepted spontaneous participation were randomly combined into teams of two each. For two residents in a team, each sequentially took on the role of a practitioner and once as an assistant for tracheal intubations by changing the position of the hand holding the tube; one time, the position of the hand holding the tube was placed in the air, and the other time, the position of the hand holding the tube was placed on the cheek of the manikin. For the assistant role, residents performed stylet removal with two hands. Investigators filmed a video of the tube movement while the assistant pulling up the stylet at 1/8x speed. While analyzing the captured videos, it was measured how much the tube held by the intubation practitioner went in front or how far back during the process of pulling the stylet.

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • residents in the department of Anesthesia and Pain Medicine

Exclusion criteria

  • refusal for participation

Treatment and study plan

hand position

Procedure

For tracheal intubation with a stylet for a manikin, one time, the position of the hand holding the tube was placed in the air, and the other time, the position of the hand holding the tube was placed on the cheek of the patient, while the assistant pulling back the stylet.

Primary outcomes

  1. tube movement distance

    Time frame: procedure (at the time when the assistant pulling back the stylet)

    tube movement distance in the process of pulling out the stylet by the assistant

Sponsors and collaborators

Lead sponsor

Seoul National University Hospital

Other

Collaborators

  • SMG-SNU Boramae Medical Center

Registry information

Official study title

The Effect of Practitioner's Hand Position on Tracheal Tube Movement While Removal of Stylet During Tracheal Intubation

Important dates

Study start
2020
Primary completion
2021
Study completion
2021
First posted
Mar 4, 2021
Registry last updated
Sep 13, 2023