Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07670117

HAIQU (Hospital AIr QUality)

The purpose of this research is to assess whether integration of an aerosol biosensor and air quality risk assessment software that integrates into a building management system will improve indoor air quality metrics in hospital environments and reduces risk factors associated with respiratory disease transmission.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Mayo Clinic Arizona, Phoenix, Arizona, United States

Loading trial locations.

About this study

Executive Summary. The Hospital AIr QUality (HAIQU) team will develop a biosensor and risk assessment software to detect pathogens in indoor air, to be integrated with building management system (BMS), focusing on improving indoor air quality in hospitals to reduce disease transmission and enhance patient outcomes. The HAIQU biosensor will combine high-flow-rate aerosol collection highly sensitive and specific CRISPR detection, and digital droplet microfluidics to continuously detect multiple viral, bacterial, and fungal pathogens from indoor air. The HAIQU risk assessment software will combine multi-scale modeling into a 'digital twin', or virtual representation of an indoor space to model pathogen distribution and exposure risk to occupants. The HAIQU tools will be applied in clinical studies within the emergency departments (EDs) of Mayo Clinic campuses in MN, WI, AZ, and FL. Integrating with building control systems, the HAIQU biosensor and software will inform strategies to mitigate bioaerosol risks, enhance productivity, save energy and costs, and protect the health of staff and patients. By ensuring clean and safe indoor air, these tools will contribute to smarter, more resilient buildings that improve cognitive performance, wellness, and overall human health.

Goals and Impact. Although people spend the majority of our time indoors, indoor air quality (IAQ) is often overlooked, with more attention given to outdoor air quality. However, clean indoor air is essential for health and well-being. Monitoring of indoor air currently lags behind other 'big data' surveillance technologies, such as wearable health monitors and disease tracking. HAIQU aims to bridge this gap by developing rapid, real-time biosensing and risk assessment tools for healthier and safer hospital buildings. Current biosensing methods are slow, non-autonomous, and limited to detecting only a few pathogens at a time. Typically, aerosol samples are collected onto a filter over two to eight hours, then manually processed for detection, often using nucleic acid amplification. For example, researchers at Mayo performed clinical trials using the Thermo Scientific AerosolSense paired with the Renvo Rapid PCR Test to detect influenza A/B, SARS-CoV-2, and RSV. Though advanced microfluidic nucleic acid amplification methods exist that are more conductive to multiplexing, combining these methods with continuous or semi-continuous aerosol collection for rapid, autonomous detection is still lacking. To detect bioaerosols which are present at very low concentrations (<1 per L), high flow rate sampling must be paired with highly sensitive, multiplexed detection methods. Here, the investigators propose the HAIQU biosensor, a portable device that enables rapid, autonomous, and near real-time bioaerosol detection. It combines high flow rate virtual impactors and condensers for aerosol capture with drop-based microfluidics, CRISPR-Cas-based detection, and multiplexed barcoding. The healthcare environment provides an ideal use case for the proposed technologies. In EDs, patients often present with undiagnosed infectious diseases that can lead to significant exposures and outbreaks among staff, patients, and visitors, sometimes only recognized after diagnosis. Detection of airborne pathogens can prevent and reduce hospital-acquired infections, which are a leading cause of illness and lost worktime.

TECHNICAL AREA 1: The final HAIQU biosensor will be capable of detecting multiple pathogens (25 real-world, viral + bacterial + fungi; 100 lab-based) with >95% sensitivity and >99% specificity, once every 45 minutes.

TECHNICAL AREA 2: HAIQU risk assessment software will include a multiscale modeling framework to predict and assess infectious disease risk in indoor environments. The multi-scale modeling framework incorporates scales from individual events to room-level and system-level information, to yield outputs and predictions of bioaerosol dispersion, infection risk, number infected, intervention recommendations, and energy calculations.

TECHNICAL AREA 3: Multi-site field trials using the HAIQU biosensor and software in Mayo Clinic's emergency departments will be performed targeting a 25% decrease in facility-related incidence of each targeted respiratory illness relative to baseline data. Biosensor data will be combined with air quality sensing data and multi-system building controls and intervention.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Target Group:

  • Mayo Clinic Staff working in ED with a minimum of .7 FTE in Midwest (MN and WI), Phoenix (AZ), or Jacksonville (FL) and patient contact.

Reference Group:

  • Mayo Clinic Staff working in primary care with a minimum of .7 FTE. in Rochester (MN), Phoenix (AZ), or Jacksonville (FL) and patient contact

Exclusion criteria

  • Any participant who does not meet either of the inclusion criteria.

Treatment and study plan

Self-swab test

Diagnostic Test

Participants will self-report when they are experiencing respiratory symptoms and will be asked for a self-swab to be used for data analysis.

Primary outcomes

  1. Number of participants to experience acute respiratory infection (ARI) symptoms

    Time frame: 3 years

    Symptoms include: at least 2 upper respiratory symptoms for at least 24 hours; OR at least 2 symptoms that include an upper/lower respiratory symptom and a systemic symptom (fever, fatigue, body aches, headache, decreased appetite) for at least 24 hours

Secondary outcomes

  1. Number of confirmed cases of acute respiratory infections

    Time frame: 3 years

    Number of cases confirmed by at least one viral panel-positive swab detected by RT-PCR

  2. Number of confirmed cases of lower respiratory tract disease

    Time frame: 3 years

    Number of cases of lower respiratory tract disease confirmed by at least one viral panel-positive swab detected by RT-PCR

Study contacts

Contact information is provided by the study sponsor or research team.

HAIQU Research Staff

CONTACT

[email protected]

507-422-3077

Sponsors and collaborators

Lead sponsor

Mayo Clinic

Other

Collaborators

  • Advanced Research Projects Agency for Health
  • Roche Pharma AG

Registry information

Official study title

HAIQU (Hospital AIr QUality): Breathing Life Into Patient Care

Acronym: HAIQU

Important dates

Study start
2026
Primary completion
2029
Study completion
2029
First posted
Jun 26, 2026
Registry last updated
Jun 29, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.