Ainshams university
Cairo, Egypt
NCT Number: NCT06737003
to evaluate the efficacy of Nasal high frequency oscillatory ventilation (NHFOV) and Vapotherm in comparison to nasal Continuous positive airway pressure (CPAP) as a primary noninvasive respiratory support in preterm neonates
Looking for future studies?
Notify Me25 week–34 week
All sexes
Interventional
Not applicable
Cairo, Egypt
Out of 105 preterm neonates assessed for eligibility, 15 neonates were excluded: 3 had confirmed congenital heart disease, 2 had cleft palate, and 10 parents/guardians refused to consent . 90 neonates were randomly allocated to the three noninvasive modes using a computer-based randomization program, with 30 neonates in each group. Sealed envelopes containing treatment assignments were opened in a sequential manner. No crossover was allowed in the study.
NHFOV group: was delivered by SLE 6000 device (Wipro GE Healthcare Private Limited, Bengaluru, Karnataka). Settings: amplitude range (20:35) cm H2O, frequency range (8-12) HZ, Mean airway pressure (MAP) range (6:10) cm H2O, and Inspiration :Expiration (I:E) ratio 1:1 to 1:2 in case of air trapping, using nasal prongs .
Vapotherm Group: was delivered by Vapotherm Device (Vapotherm, INC, USA). Settings: flow rate 4-6 L/min, with temperature 36-37 °C and Fraction of inspired oxygen(FiO2) titrated as needed to achieve target Saturation of peripheral oxygen (SpO2) (90% to 94%) using soft nasal cannula interface .
Nasal CPAP Group: was delivered by MEDIN CNO device (Medin Medical Innovations GmbH, Olching, Germany). Settings: pressure ranging from 5 to 8 cm H2O to maintain SpO2 from 90% to 94% using bi-nasal prongs.
Clinical examination and routine neonatal care:
Newborns included in the study were subjected to detailed perinatal and family history, thorough clinical examination, and standard neonatal care practices. Each infant's clinical condition, vital data, daily weight, and total enteral and parenteral fluid intake were monitored and recorded.
Respiratory management:
-Criteria for starting noninvasive ventilation according to NICU protocol of Ain Shams University, including:
Criteria for failure of noninvasive ventilation and shifting to invasive ventilation with surfactant administration according to NICU protocol of Ain Shams University, including:
Criteria for weaning off non-invasive ventilation (success of non-invasive ventilation) in this study were based on stability criteria.
Laboratory analysis Laboratory investigations performed included baseline complete blood count with differential leukocyte using Coulter Counter GEN-S (Coulter Corporation, IN), and a high-sensitivity C-reactive protein measurement using a quantitative assay by Latex agglutination slide test, spin react, and Spain (Omega Diagnostics LTD, UK); the detection limit for CRP was 6 mg/L . Blood gases were analyzed using ABL 5 blood gas analyzer (Diamond Diagnostics, USA) at baseline, following initiation of noninvasive support and were repeated as clinically indicated.
Radiological analysis:
A- chest x-ray was done initially for the diagnosis of RDS and repeated as clinically indicated.
B-Abdominal X-ray was done when feeding intolerance and necrotizing enterocolitis (NEC) were suspected.
During examination, neonates were in a resting state and lying in a supine position with temperature maintained, and the examinations were done within 15 minutes. Environmental light intensity was low and constant. Phototherapy was suspended during measurements. To avoid crying episodes and stress conditions, gentle handling consisting of delicate touching and calm voice tones were applied, along with pacifiers and stimulation of non-nutritional sucking in order to pacify the baby in each mode of noninvasive ventilation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
-
-Preterm neonates with gestational age ≤ 35 weeks with RDS that need noninvasive ventilatory support primarily.
Exclusion criteria
NHFOV was administered using the SLE 6000 device manufactured by Wipro GE Healthcare Private Limited in Bengaluru, Karnataka. The initial amplitude was set at 25 cm H2O and adjusted to a maximum of 35 cm H2O based on clinical response. The frequency was set at 12 Hz. The mean airway pressure (MAP) was initiated at 6 cmH2O and titrated up to 10 cmH2O based on clinical assessment. The I:E ratio was maintained between 1:1 to 1:2 in cases of air trapping, using nasal prongs •
The Hi-VNI Vapotherm was administered using the Vapotherm device, manufactured by Vapotherm, INC, USA. Initially, the flow rate was set at 4 L/min and adjusted accordingly to achieve the desired clinical outcome, with a maximum flow rate of 8 L/min when necessary. The temperature was maintained at 36-37°C, and the FiO2 was adjusted as required to attain the target SpO2 range of 90% to 94%، using soft nasal cannula interface
CPAP therapy was administered using the MEDIN CNO device, developed by medin Medical Innovations GmbH in Olching, Germany. The initial pressure was set at 5 cmH2O and adjusted accordingly to achieve the desired clinical outcome, with a maximum pressure of 8 cmH2O. This approach aimed to maintain the target oxygen saturation (SpO2) levels between 90% and 94%، using bi-nasal with midline prongs
Time frame: 1year
By Assessment of the need for invasive mechanical ventilation (IMV) during the first 72 hours after enrollment in one of the groups.
Time frame: 1 year
with two dimensional echocardiography using Vivid 9,GE Ultrasonography machine (Norway) with 6 MHz transducer frequency.
Time frame: 1 year
with transcranial ultrasonography by; Samsong Medison Co ,Korea. Doppler applied to the major cerebral arteries .
Time frame: 1 year
with Doppler sonography by; Samsong Medison Co ,Korea.
Ain Shams University
Other
Acronym: RDS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04014920
Body Weight, Intensive Care Unit
Montpellier, Herault, France
View Trial DetailsNCT07291271
Ablation Techniques, Adenocarcinoma
Amsterdam, Netherlands
View Trial DetailsNCT03657368
Orthopedic Surgery, Pathologic Processes
Cleveland, Ohio, United States
View Trial DetailsNCT04376918
Pathologic Processes, Pathological Conditions, Signs and Symptoms
Jerusalem, Israel
View Trial Details