Wenzhou People's Hospital
Wenzhou, Zhejiang, 325000, China
NCT Number: NCT07680985
Adenomyosis is a common gynecological condition that can cause menstrual pain, heavy menstrual bleeding, anemia, and reduced quality of life. The levonorgestrel-releasing intrauterine system is commonly used as a conservative treatment, but displacement or expulsion of the device may occur, especially in patients with an enlarged uterus or a deep uterine cavity.
This study evaluated whether combining an Indomethacin-GyneFix intrauterine device with a levonorgestrel-releasing intrauterine system could improve device stability in patients with adenomyosis. Eligible participants were randomly assigned to receive GyneFix IUD plus LNG-IUS, ring IUD plus LNG-IUS, or LNG-IUS alone. Participants were followed for 6 months after device placement. The main outcome was device displacement or expulsion at 6 months. Other outcomes included menstrual pain, menstrual blood loss, uterine volume, hemoglobin, CA125, adverse events, and treatment acceptance.
Looking for future studies?
Notify Me20 year–55 year
Female
Interventional
Not applicable
Wenzhou, Zhejiang, 325000, China
This was a single-center, prospective, parallel-group, randomized controlled trial conducted at Wenzhou People's Hospital in patients with adenomyosis. The study was designed to compare three intrauterine treatment strategies for improving the stability of a levonorgestrel-releasing intrauterine system in patients with different uterine cavity depths.
Eligible patients were women diagnosed with adenomyosis who had no current desire for pregnancy, had no contraindications to intrauterine device placement, and were able to complete scheduled follow-up. After written informed consent was obtained, participants were randomly assigned in a 1:1:1 ratio to one of three groups: GyneFix IUD plus LNG-IUS, ring IUD plus LNG-IUS, or LNG-IUS alone.
In the GyneFix IUD plus LNG-IUS group, the Indomethacin-GyneFix IUD was used as an anchoring device to stabilize the LNG-IUS. The anchoring knot of the GyneFix IUD was placed in the uterine fundal myometrium under ultrasound guidance, allowing the LNG-IUS to remain suspended and stabilized within the uterine cavity. In the ring IUD plus LNG-IUS group, a ring IUD was placed together with the LNG-IUS to provide passive mechanical support. In the LNG-IUS-alone group, the LNG-IUS was inserted according to the standard procedure.
All procedures were performed under real-time ultrasound guidance by experienced gynecologists. Participants were followed at approximately 1 month, 3 months, and 6 months after device placement. Follow-up assessments included symptom evaluation, gynecological examination, ultrasound assessment of device position and uterine parameters, laboratory testing, adverse event monitoring, and treatment acceptance assessment.
The primary outcome was intrauterine device displacement or expulsion at 6 months. Secondary outcomes included changes in dysmenorrhea measured by visual analogue scale, menstrual blood loss measured by pictorial blood loss assessment chart, uterine volume, hemoglobin, serum CA125, adverse events, and patient acceptance. A subgroup analysis was planned according to uterine cavity depth.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Indomethacin-GyneFix IUD was used as an anchoring device to stabilize the levonorgestrel-releasing intrauterine system. The LNG-IUS was connected to the upper portion of the GyneFix IUD with non-absorbable surgical suture. Under real-time ultrasound guidance, the anchoring knot of the GyneFix IUD was implanted into the uterine fundal myometrium, allowing the LNG-IUS to remain suspended and stabilized within the uterine cavity.
Other names: GyneFix IUD Plus LNG-IUS, GyneFix IUD Combined With LNG-IUS, Mirena Plus GyneFix IUD
The ring IUD and the levonorgestrel-releasing intrauterine system were sequentially inserted into the uterine cavity under real-time ultrasound guidance. The ring IUD was positioned near the upper uterine cavity or fundal region to provide passive mechanical support for the LNG-IUS. The LNG-IUS was then released in the conventional manner with its transverse arms extended.
Other names: Ring IUD Combined With LNG-IUS, LNG-IUS Plus Ring IUD, Support-Based IUD Fixation
The levonorgestrel-releasing intrauterine system was inserted according to the standard procedure under real-time ultrasound guidance. Correct placement required full extension of the transverse arms and positioning of the device at the uterine fundus.
Other names: Levonorgestrel-Releasing Intrauterine System, Mirena, LNG-IUS
Time frame: 6 months after device placement
The proportion of participants with intrauterine device displacement or expulsion at 6 months after device placement. Device displacement or expulsion was assessed by gynecological examination and ultrasound evaluation according to predefined criteria for intrauterine device position.
Time frame: Baseline, 1 month, 3 months, and 6 months after device placement
Change in dysmenorrhea severity measured by the visual analogue scale. The VAS score ranges from 0 to 10, with higher scores indicating more severe pain.
Time frame: Baseline, 1 month, 3 months, and 6 months after device placement
Change in menstrual blood loss measured by the pictorial blood loss assessment chart. Higher PBAC scores indicate greater menstrual blood loss.
Time frame: Baseline, 3 months, and 6 months after device placement
Change in uterine volume measured by gynecological ultrasound. Uterine volume was calculated using three-dimensional uterine measurements.
Time frame: Baseline, 3 months, and 6 months after device placement
Change in hemoglobin level measured from venous blood samples to evaluate improvement in anemia associated with heavy menstrual bleeding.
Time frame: Baseline, 3 months, and 6 months after device placement
Change in serum cancer antigen 125 level measured by laboratory testing. CA125 was used as an indirect marker of adenomyosis disease activity.
Time frame: Up to 6 months after device placement
Incidence of adverse events during follow-up, including irregular vaginal bleeding, low back pain, lower abdominal discomfort, increased vaginal discharge, pelvic inflammatory disease, ovarian cysts, breast tenderness, acne, weight gain, device removal for symptoms, uterine perforation, device displacement, and device expulsion.
Time frame: 6 months after device placement
Treatment acceptance assessed by questionnaire at 6 months, including willingness to choose the same treatment again and willingness to recommend the treatment to others with similar conditions.
Wenzhou People's Hospital
Other
Clinical Efficacy and Safety of Indomethacin-GyneFix IUD Combined With a Levonorgestrel-Releasing Intrauterine System in Patients With Adenomyosis and Different Uterine Cavity Depths
Acronym: GYNEFIX-AM
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01821001
Adenomyosis, Dysmenorrhea
Rochester, Minnesota, United States
View Trial DetailsNCT01601366
Adenomyosis, Dysmenorrhea
View Trial DetailsNCT01793584
Adenomyosis, Adnexal Diseases
Dallas, Texas, United States
View Trial DetailsNCT02201719
Adenomyosis, Dysmenorrhea
Oslo, Norway
View Trial Details