NCT Number: NCT03662594

Growth of High-Quality Oxides on The Inner Surface of ECMO Circuit by ALD to Reduce Thrombus Formation

This study evaluate thermal ALD (T-ALD) and plasma-enhance ALD (PE-ALD) processes modified cardiopulmonary bypass (CPB) tubing to investigate anticoagulation properties.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

20 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

National Taiwan University Hospital

Taipei, 100, Taiwan

About this study

ECMO is a technique which is currently being used worldwide for providing life support for patients experiencing both pulmonary and cardiac failure. Though ECMO can effectively rescue life at the initial scene, being invasive, complex, resource intensive, and serious related complications developing on the following days of ECMO support have greatly restricted it use. The major causes of ECMO-related mortality and morbidity are serious coagulopathy, either bleeding (7-34%) or thrombosis (8-17%). Contact of high extracorporeal blood flow and the large artificial surfaces plays a critical role leading to the subsequent coagulopathy. Systemic heparin and heparin-bonded circuits is usually used to reduce thrombus. However, non-urgent invasive procedures should be avoided or minimized during that support and regular clinical monitoring to guide the adjustment of optimal dosage is mandatory making the clinical care intensive. Whereas the pharmacological interventions may bring the risk of critical imbalance between hemostasis and thrombosis, efforts to modify the ECMO system focusing on improvement of biocompatibility seem a fundamental way particularly regarding the extended periods of ECMO use. ZrO2 and Al2O3 are more excellent biocompatible and hemocompatible materials compared with PVC (polyvinylchloride) which is the current material of ECMO circuit. Despite the broad applications of ZrO2 and Al2O3 in artificial implants, traditional thin-film coating techniques are unable to deposit these hemocompatible oxides on the inner surface of the PVC tubing in ECMO circuit. In this subproject, the investigators will apply a new technique of atomic layer deposition (ALD) to coat biocompatible and hemocompatible ZrO2/Al2O3 nanolaminate thin films on the inner surface of ECMO tubing to suppress the device-induced coagulopathy. ALD is a thin-film deposition technique for preparing high-quality oxides with atomic-layer accuracy. It offers many benefits including accurate thickness control, excellent conformality, high uniformity, low defect density, good reproducibility, and low deposition temperature. These characteristics clearly accounts for the feasibility to deposit high-quality hemocompatible oxide thin films on the whole surface of complex 3-D structures, such as the inner surface of ECMO tubing, using the ALD technique. The newly-prepared ECMO circuit will then undergo in vitro tests and animal study to carefully examine the safety and effectiveness of improvement of hemocompatibility.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adults
  • Weighing more than 50 kg

Exclusion criteria

  • Pregnancy
  • Smoking
  • Chewing betel nut
  • History of any blood or cancer
  • Taking anticoagulants

Treatment and study plan

ECMO

Other

In this project, the investigators will apply a new technique of atomic layer deposition (ALD) to coat biocompatible and hemocompatible ZrO2/Al2O3 nanolaminate thin films on the inner surface of ECMO tubing to suppress the device-induced coagulopathy. ALD is a thin-film deposition technique for preparing high-quality oxides with atomic-layer accuracy. It offers many benefits including accurate thickness control. These characteristic clear accounts of the high-quality hemocompatible oxide thin films on the whole surface of complex 3-D structures, such as the inner surface The newly-prepared ECMO circuit will then undergo in vitro tests and animal study to carefully examine the safety and effectiveness of improvement of hemocompatibility.

Primary outcomes

  1. Protein content or configuration changed

    Time frame: Within 3 days after blood drawed

    Use ELISA to measuring the content or configuration of a protein when blood contact material, such as human serum albumin and human plasma fibrinogen etc.

Sponsors and collaborators

Lead sponsor

National Taiwan University Hospital

Other

Registry information

Official study title

Growth of High-Quality Oxides on The Inner Surface of ECMO Circuit by Atomic Layer Deposition to Reduce Thrombus Formation

Important dates

Study start
2018
Primary completion
2018
Study completion
2018
First posted
Sep 7, 2018
Registry last updated
Sep 7, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.