Terigi Augusto Scardovelli
Mogi das Cruzes, São Paulo, 08780-911, Brazil
NCT Number: NCT03750045
This study is to test the system composed by a 3D virtual environment, attached to the Leap Motion, evaluating its effects on the rehabilitation of hand movements in patients with motor alteration.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Mogi das Cruzes, São Paulo, 08780-911, Brazil
In order to elaborate the virtual environment, softwares for 3D content creation were used. The virtual environment is formed by four phases, each one having three spheres that are supposed to be inserted, one by one, into a hole located on the scenario floor. Each phase presents a level of difficulty, from pushing the object to performing the grip movement. By the end of each phase, a log file is generated with the time spent on it.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The grip strength was evaluated through a dynamometer JAMAR 5030-J, formed by two parallel steel bars, one stationary and a mobile one, which can be adjusted in five different positions. The volunteer was sitting with a neutrally rotated abducted shoulder, elbow flexed at 90°, the forearm in neutral position, and the wrist between 0° and 30° of extension, 0° to 15° of ulnar variance and it was requested that he or she made the grip movement. This test was performed three times with a one-minute-break between each one.
The motor coordination evaluation was made through the measurement of the time spent to perform the task of fitting. To do so, a wooden box was built. In its upper part, there is a circular orifice with 6 cm of diameter.
The system proposed is composed by a virtual environment and an access device. The Leap Motion was used as the access device, making it possible to capture the movements performed by the hands.
Time frame: 120 minutes
The intervention was composed by 8 sessions of 15 minutes each, where the volunteers used a virtual environment attached it to a Leap Motion, which is a sensor that allows to capture the movements that are produced by the hands and reproduce them in a computer through a 3D virtual environment in order to stimulate the execution of their finer movements.
Time frame: Immediately after at the Session 1, 4 and 8.
The motor coordination evaluation was made in the first, fourth and eighth sessions. Each volunteer used three balls, or spheres, of different sizes (small, medium, large). The objective was to insert each ball in each orifice. The time was measured with a chronometer.
Time frame: Immediately after at the Session 1, 4 and 8.
The grip strength (kgf) was evaluated in the first, fourth and eighth sessions.
University of Mogi das Cruzes
Other
Proposal for Grip Movement Training for Adults With Fine Motor Limitation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05887778
Disease, Hand Injuries
Poznan, Poland
View Trial DetailsNCT06086392
Arm Injuries, Disease
Skórzewo, Poznań, Poland
View Trial DetailsNCT06155617
Disease, Edema
Newport News, Virginia, United States
View Trial DetailsNCT05320211
Behavior, Disease
Amsterdam, Netherlands
View Trial Details