University Hospital Balgrist
Zurich, Canton of Zurich, 8008, Switzerland
NCT Number: NCT05594888
Maximum isometric grip strength (MIGS) is a cost-effective, easily accessible, valid and reliable outcome measure for assessing upper body strength in both, adults and children. The the JAMAR Hydraulic Hand Dynamometer is the current gold standard for measuring MIGS. For certain age- and activity-groups, alternative devices may be more appropriate. To date, the quality criteria (test-retest-reliability and validity) of the JAMAR Smart Hand Dynamometer and the Martin Vigorimeter compared to the current gold standard are not yet investigated. Furthermore, no reference values for different age-, sex-, or activity level groups exist with regard to underlying disease entities for these three devices.
Looking for future studies?
Notify Me10 year and older
All sexes
Observational
Zurich, Canton of Zurich, 8008, Switzerland
This quality analysis of test-retest reliability and validity (PART 1) serves as a basis for a further sensitivity analysis, whereby in a second step, a database with valid personalised age-, sex- and activity-related reference values for the respective measurement instrument, considering chronic concomitant diseases, is to be generated. The objectives of this study are therefore to 1) assess the test-retest reliability (intrasubject and intersession) and validity of JAMAR© Hydraulic and JAMAR© Smart dynamometers and Martin Vigorimeter (PART 1) and 2) undertake a sensitivity analysis providing valid personalised reference values for precision medicine (PART 2).
Thus, no study has yet comprehensively investigated all relevant influencing factors in a single and thus homogeneous study setting, so bias can be expected from this alone. The findings of this two-step study should enable physicians and therapists to compare the grip strength measurements of their patients with normative values in relation to their age, sex and activity group, as well as to any underlying chronic diseases that may be present. This allows realistic treatment and training goals to be set and patient performance to be interpreted.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Part 1:
Inclusion criteria
Part 2:
Exclusion criteria
Part 1 and 2:
Time frame: 5 minutes
Test-retest reliability of the JAMAR© Smart Dynamometer, the JAMAR© Hydraulic Dynamometer and Martin Vigorimeter measuring MIGS will be assessed by intrasubject realiability.
--> 5 attempts per device and dominant/adominant hand will be measured.
Time frame: 5 minutes
Test-retest reliability of the JAMAR© Smart Dynamometer, the JAMAR© Hydraulic Dynamometer and Martin Vigorimeter measuring MIGS will be assessed by intersession realiability.
--> 5 attempts per device and dominant/adominant hand at two different days will be measured.
Time frame: 5 minutes
Validity of the JAMAR© Smart Dynamometer, the JAMAR© Hydraulic Dynamometer and Martin Vigorimeter measuring MIGS will be assessed by plotting the differences in grip force measurements of the 3 measurement devices against their means, with ± 1.96 SD as cut-off values (limits of agreement).
--> 5 attempts per device and dominant/adominant hand will be measured.
Time frame: 10 minutes
Evaluation of comparability of MIGS measurement assessed with the JAMAR© Smart Dynamometer, the JAMAR© Hydraulic Dynamometer and the Martin Vigorimeter
-> Best out of 3 attempts per device and dominant/adominant hand
Time frame: 1 minute
Age-specific refence values for MIGS assessed with the JAMAR© Hydraulic. Age is assessed by the number of years. Thirteen age groups are established with an increment of five to ten years: 10-14/15-19/20- 29/30-39/40-44/45-49/50-54/55-59/60-64/65-69/70-74/75-79/80+
Time frame: 1 minute
Age-specific refence values for MIGS assessed with the JAMAR© Smart. Age is assessed by the number of years. Thirteen age groups are established with an increment of five to ten years: 10-14/15-19/20- 29/30-39/40-44/45-49/50-54/55-59/60-64/65-69/70-74/75-79/80+
Time frame: 1 minute
Age-specific refence values for MIGS assessed with the Martin Vigorimeter. Age is assessed by the number of years. Thirteen age groups are established with an increment of five to ten years: 10-14/15-19/20- 29/30-39/40-44/45-49/50-54/55-59/60-64/65-69/70-74/75-79/80+
Time frame: 0.5 minute
Sex-specific refence values for MIGS assessed with the , JAMAR© Hydraulic. Sex is recorded as male or female (biological sex).
Time frame: 0.5 minute
Sex-specific refence values for MIGS assessed with the JAMAR© Smart. Sex is recorded as male or female (biological sex).
Time frame: 0.5 minute
Sex-specific refence values for MIGS assessed with the Martin Vigorimeter. Sex is recorded as male or female (biological sex).
Time frame: 2 minutes
Physical activity-specific reference values for MIGS measurements assessed with the JAMAR© Hydraulic.
The IPAQ, the PAQ-A and the PAQ-C are used to assess individual levels of physical activity through all age groups. The IPAQ is a reliable and valid instrument that shows very good repeatability, was designed for people aged 18-65 years and is validated for persons aged 18-84 years. Adolescents between 15 and 18 years of age are assessed using the PAQ-A and children aged 10-14 years are assessed by the PAQ-C.
Time frame: 2 minutes
Physical activity-specific reference values for MIGS measurements assessed with the JAMAR© Smart.
The IPAQ, the PAQ-A and the PAQ-C are used to assess individual levels of physical activity through all age groups. The IPAQ is a reliable and valid instrument that shows very good repeatability, was designed for people aged 18-65 years and is validated for persons aged 18-84 years. Adolescents between 15 and 18 years of age are assessed using the PAQ-A and children aged 10-14 years are assessed by the PAQ-C.
Time frame: 2 minutes
Physical activity-specific reference values for MIGS measurements assessed with the Martin Vigorimeter.
The IPAQ, the PAQ-A and the PAQ-C are used to assess individual levels of physical activity through all age groups. The IPAQ is a reliable and valid instrument that shows very good repeatability, was designed for people aged 18-65 years and is validated for persons aged 18-84 years. Adolescents between 15 and 18 years of age are assessed using the PAQ-A and children aged 10-14 years are assessed by the PAQ-C.
Time frame: 1 minute
Refence values for subjects with different disease entities that might influence target value of MIGS measurement assessed with the JAMAR© Hydraulic
Any chronic disease entities that may be present, (possible chronic diseases according to organ class) are recorded:
Time frame: 1 minute
Refence values for subjects with different disease entities that might influence target value of MIGS measurement assessed with the JAMAR© Smart
Any chronic disease entities that may be present, (possible chronic diseases according to organ class) are recorded:
Time frame: 1 minute
Refence values for subjects with different disease entities that might influence target value of MIGS measurement assessed with the Martin Vigorimeter.
Any chronic disease entities that may be present, (possible chronic diseases according to organ class) are recorded:
Time frame: 10 minutes
The OSTRC questionnaire is used to assess general health before the first study appointment.
The OSTRC contains four key questions recording the level of participation and performance impairment and the degree of symptoms caused by injury or illness. A severity score is then calculated based on these four questions.
Johannes Scherr
Other
GRIP: Evaluation of the Comparability of the Maximum Isometric Grip Strength Measurement Assessed With the JAMAR© Hydraulic Hand Dynamometer, the JAMAR© Smart Hand Dynamometer and the Martin Vigorimeter
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06069908
Edema, Grip
Istanbul, Gaziosmanpaşa, Turkey (Türkiye)
View Trial DetailsNCT05946018
Behavior, Behavioral Symptoms
Dallas, Texas, United States
View Trial DetailsNCT06602401
Dexterity, Grip
Izmir, Çiğli, Turkey (Türkiye)
View Trial DetailsNCT06086262
Athlete, Grip
Giza, Egypt
View Trial Details