G7 Dual Mobility with Vivacit-E bearing
Devicehip arthroplasty with G7 Dual Mobility Vivacit-E bearing
NCT Number: NCT05548972
This study is a global, multi-center, prospective, non-controlled, non-randomized, post-market clinical follow-up study. The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Dual Mobility Acetabular System when used with the Vivacit-E or Longevity polyethylene hip bearing and instrumentation in primary total and revision (total) hip arthroplasty
Interested in participating?
Request Info18 year–80 year
All sexes
Interventional
Not applicable
UZ Leuven, Leuven, Belgium
The G7 Dual Mobility construct offers dislocation resistance without the need to constrain the femoral head, providing stability and high range of motion. Dual Mobility systems decrease the risk of post-operative instability in high-risk patients in both primary and revision arthroplasties.
This study will enroll up to 358 hips globally, 179 for the Vivacit-E and 179 for the Longevity polyethylene bearings. From the 179 hips per bearing variant, the study will enroll 60 primary and 119 revision arthroplasty hips. The Longevity bearing variant will only be enrolled in the US, as it is not CE marked and unregistered in the APAC market. Vivacit-E bearings will be enrolled globally.
A maximum of 20 study centers will be selected globally. To minimize potential bias and to maximize our ability to assess inter-site differences, each study site will target maximum 24 primary hip arthroplasties and maximum 47 revision hip arthroplasties. Each site is encouraged to enroll both, primary and revision, subjects.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
hip arthroplasty with G7 Dual Mobility Vivacit-E bearing
hip arthroplasty with G7 Dual Mobility Longevity bearing
Time frame: 10 years
Survival of the implant system based on removal of the study device
Time frame: 10 years
Safety of the system will be assessed by monitoring the frequency and incidence of adverse events. Relation of the events to implant, instrumentation and/or procedure should be specified.
Time frame: 10 years
The modified Harris Hip Score measures pain, function and functional activities using a self assessment. The overall score runs from 0-100 with 100 representing the best outcome.
Time frame: 10 years
The Oxford Hip Score measures pain and function using a self assessment. The overall score runs from 0-48 with 48 representing the best outcome.
Time frame: 10 years
The EQ-5D-5L measures the quality of life using a self assessment. The questionnaire includes 5 dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression.
Time frame: 5 years
X-ray evaluation to find significant radiographic findings such as radiolucency, osteolysis, atrophy, hypertrophy, component migration, device fracture, heterotopic ossification, etc
Zimmer Biomet
Industry
Global, Multicenter and Prospective Post-Market Clinical Follow-Up Study of the G7® Dual Mobility Acetabular System With Vivacit-E® or Longevity® Poly Bearing & Instrumentation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05144191
Arthritis, Arthritis, Rheumatoid
Phoenix, Arizona, United States
View Trial DetailsNCT03409666
Arthritis, Arthritis, Rheumatoid
Roosendaal, Netherlands
View Trial DetailsNCT02353377
Arthritis, Bone Diseases
View Trial DetailsNCT04993638
Arthritis, Femoral Fractures
Avignon, France
View Trial Details