NCT Number: NCT06335498
AFGen1 is indicated for use on symptomatic or asymptomatic adults who are at risk of developing or who have atrial fibrillation, where a software assisted analysis of ambulatory ECG is needed to identify episodes of Afib. The purpose of this study is to establish further evidence for the clinical performance of AFGen1 on human participants.
Looking for future studies?
Notify Me18 year–90 year
All sexes
Observational
Gig Harbor, Washington, 98335, United States
The primary purpose of this study is to demonstrate the ECG signal acquired by the AFGen1 device is of adequate quality and is suitable to support its intended use for the detection of Afib. This will be evaluated by comparing the ECG data acquired by AFGen1 to that acquired by an FDA cleared 12-lead ECG device using a Bland-Altman analysis of the R-R intervals and R amplitude measurements and Eigenvector magnitudes derived from principal component analyses of simultaneously captured waveforms measured by both devices by both devices. The ECG waveforms from both devices will also be adjudicated by 2 independent cardiologists. The study will also seek to demonstrate that there is no degradation in the quality of the ECG signal it acquires when the device is placed in an anticipated misplacement position to that directed by the instructions for use of the device. Finally the study will seek to confirm the adhesive performance of the device is appropriate to support its intended use per the requirements of sections 4.4 and 5.4 of ANSI AAMI EC12-1 . Another purpose of the study is to collect extended 5 minute ECG recordings by the subject periodically triggering the device while wearing the device for 7 (+3) days. This data will be used for product development purposes.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Measure ECG with 12 lead device at same time that AFGen1 is monitoring ECG
Subject triggers AFGen1 to perform an extended measurement during wear period
Time frame: 1 day
The waveform characteristics for both the 7- day wear and misplacement elements of this study, the limits of agreement (LoA) from the Bland-Altman analyses shall not exceed the the maximum allowed clinically significant difference between methods i.e. 80ms for R-R. 0.2 mV for R-peak amplitude) for 95% of the subjects on a per-subject basis.
Time frame: 1 day
For the qualitative equivalence evaluation according to the two cardiologists confirmation of equivalence must be greater than 95%.
Time frame: 7 to 10 days
The overall average wear time for the device must be greater than 7-days.
TriVirum, Inc.
Industry
A Further Study of the Clinical Performance of AFGen1
Acronym: CS3
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06076798
Afib, Arrhythmias, Cardiac
San Diego, California, United States
View Trial DetailsNCT05295056
Afib, Arrhythmia Atrial
St Louis, Missouri, United States
View Trial DetailsNCT03715361
Arrhythmias, Cardiac, Atrial Fibrillation
Aachen, North Rhine-Westphalia, Germany
View Trial DetailsNCT01997905
Afib, Arrhythmias, Cardiac
St. Helena, California, United States
View Trial Details