Huadong Hospital affiliated to Fudan University
Shanghai, Shanghai Municipality, 200040, China
NCT Number: NCT03405506
Quantitative Flow Ratio (QFR) is a novel method for evaluating the functional significance of coronary stenosis. Virtual stent implantation technique combined with QFR was recently developed to predict the functional significance of coronary stenosis as if the stenosis was revascularized.
The purpose of this study is to evaluate the diagnostic accuracy of QFR in in tandem lesions with fractional flow reserve (FFR) as the reference standard. The secondary purpose is to evaluate the diagnostic accuracy of QFR-based virtual stent technique in predicting the FFR values after revascularizing the culprit lesion.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Shanghai, Shanghai Municipality, 200040, China
QFR is a novel method for evaluating the functional significance of coronary stenosis by calculation of the pressure drop in the vessel. 3D coronary models can be reconstructed based on two angiographic projections to obtain the geometric parameters, including vascular diameter or cross-sectional area. According to the lesion stenosis, vessel curvature, conical geometry and reference lumen characteristics, pressure drop can be calculated in real time based on its relationship with blood flow. There is no need for pressure wire and adenosine / ATP induced maximum hyperemia compared with FFR.
The FAVOR Pilot Study and FAVOR II China Study showed promising results for diagnostic accuracy in consecutive patients. However, the diagnostic accuracy of QFR in specific tandem lesions needs further investigation. Furthermore, using the virtual stent technology to accurately assess the culprit lesion and choose the optimal treatment is significant in precisely guiding PCI surgery.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
FFR measured by pressure wire, QFR computed by coronary angiographic images
Time frame: 1 hour
Diagnostic accuracy was defined as the concordance ratio of QFR evaluated outcomes (≤ 0.8 or > 0.8) with the reference standard FFR evaluated outcomes (≤ 0.8 or > 0.8)
Time frame: 1 hour
Diagnostic accuracy was defined as the concordance ratio of QFR evaluated outcomes (≤ 0.8 or > 0.8) with the reference standard FFR evaluated outcomes (≤ 0.8 or > 0.8)
Pulse Medical Imaging Technology (Shanghai) Co., Ltd
Industry
Acronym: FORTRESS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04624854
Acute Coronary Syndrome, Arterial Occlusive Diseases
Chongqing, Chongqing Municipality, China
View Trial DetailsNCT04343209
Arterial Occlusive Diseases, Arteriosclerosis
Miami, Florida, United States
View Trial DetailsNCT02057978
Arterial Occlusive Diseases, Arteriosclerosis
Shenyang, Liaoning, China
View Trial DetailsNCT01848886
Arterial Occlusive Diseases, Arteriosclerosis
Copenhagen, Denmark
View Trial Details