Mansoura University, Faculty of Dentistry, mansoura, egypt
Al Mansurah, Mansoura, Egypt
NCT Number: NCT07174791
compare fully versus partially guided all on four implants placement immediately loaded by maxillary and mandibular screw retained overdentures: A radiographic and photogrammetric measurement of accuracy of implant position and passivity of superstructures.
The measurements will be done as follows:
1. Photogrammetric scan immediately after implant instalments to measure 3D accuracy of implant position and Passivity of super structure 2. Cone beam X ray to measure the implant marginal bone height changes. 3. Implant marginal soft tissue evaluations including pocket probing depth, plaque and gingival indices. Evaluation will be done immediately, one and two years after loading.
This study is active but is not currently recruiting participants.
Notify MeAll sexes
Interventional
Not applicable
Al Mansurah, Mansoura, Egypt
Sixteen healthy, fully edentate patients will be selected from the Prosthodontic Department, Faculty of Dentistry, Mansoura University. The patients will be informing about the protocol of the study and, they will sign a written consent. The study will be ethically approved according to the faculty of dentistry principles.
Sample size and study design A power analysis was made using a computer software (G* power) to detect the prober sample size based on the results of a previous study in which the authors found a significant difference in mesiodistal measurements between two groups (computer guided implant placement Vs conventional implant placement) using a similar study design. The sample size calculation yields a total of 32 implants (16 implants\\ each group) using independent samples t-test. The following are details of sample size calculation: effect size= 0.904, Alpha (α)= .050. power (β)= .80
Patient selection i- Completely healed residual alveolar ridges ii- Angle's class I maxillo-mandibular relationship. iii- Sufficient mandibular and maxillary restorative spaces, at least 15mm evaluated by recording a tentative jaw relation.
iv- Adequate bone height in the premaxilla area, and the anterior mandibular area. This will be evaluated radiographically Exclusion criteria included (i) Systemic disorders affecting bone (such as uncontrolled diabetes mellitus and osteoporosis).
(ii) Local or general contraindication for surgical procedures. (iii) History of chemotherapy or radiation therapy to the head and neck area. (iv) Poor neuromuscular co-ordination. (v) TMJ dysfunction and parafunctional habits
Each patient will receive conventional complete denture and will be delivered and followed to adjust any post operative complains
For both groups based on the implant planning position and angulation a presurgical 3D printed model with digital analogue spaces will be constructed and scanned using photogrammetric device after connecting the multiunit digital analogues to the printed model in order to be compared to the model formed after implants placement in each group using photogrammetric device.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
-Implant marginal bone height changes will be measured by cone beam radiograph after one and two years of loading
implant placement accuracy will be evaluated using photogrammetric scan after implant insertion
Time frame: immediately after implant insertion
accuracy of implant position will be measured immediately after implant insertion by using photogrammetry scan for implants with multi-unit abutments intra-orally and on the model created from the planned implants and fitting surface of surgical guide, superimposition of both scans will be done using geomagic software to determine deviation in implant positions between both scans (Presurgical and post surgical) for both groups and calculated in fractions of millimeters, the value of deviation found in both semi-guided and fully-guided groups will be compared.
Time frame: immediately after final restoration insertion
passivity of final prosthesis will be evaluated by radiography and gap distance will me measured on radiographic software in fractions of millimeters
Time frame: 24 months after prosthesis insertion
Implant marginal bone height changes will be measured by cone beam radiograph after one and two years of loading
Mansoura University
Other
Fully Versus Partially Guided All on Four Implants Placement Immediately Loaded by Maxillary and Mandibular Screw Retained Prosthesis: A Radiographic and Photogrammetric Measurement of Accuracy of Implant Position and Passivity of Superstructures
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06870929
Completely Edentulous
Cairo, Abbasia, Egypt
View Trial DetailsNCT06219811
Completely Edentulous
Cairo, Nasr City, Egypt
View Trial DetailsNCT07284680
Implant Assesment
Al Mansurah, Dakahlia Governorate, Egypt
View Trial DetailsNCT07200011
Avitaminosis, Clinical and Radiographic Effect
Al Mansurah, Dakahlia Governorate, Egypt
View Trial Details