The Pennsylvania State University
State College, Pennsylvania, 16802, United States
NCT Number: NCT05908344
The investigators propose to examine the potential effects of the Frequen- ZZZ sleep pad - a noninvasive, unobtrusive appliance that generates a localized low-level electromagnetic field via radiofrequency, and that is used on the bed - on multiple sleep outcomes in an 8-week randomized crossover study, and to calculate the effect sizes of the intervention to inform power and sample size for future studies.
Looking for future studies?
Notify Me40 year–65 year
All sexes
Interventional
Not applicable
State College, Pennsylvania, 16802, United States
This research is a small, 8wk clinical trial testing the potential effects of an investigational device, Frequen-ZZZ Sleep Pad, on the sleep of adults 40-65 years old. The investigators aim to determine whether sleeping with the Sleep Pad, which creates a radio-frequency field around the sleeper, improves sleep. Sleep will be primarily measured using a noninvasive clinical standard method, called polysomnography (PSG), for 6 separate nights in the personal residence of participants. Sleep will also be measured both day and night with a watch-like device that measures activity, and with surveys. The investigators will look for changes in sleep quality, in sleep duration, and in the way that sleep is organized by the body ("sleep architecture"). There are 12-15 in-person appointments across the course of the study. With the data, the investigators hope to also evaluate the feasibility and effect sizes of this non-pharmacological intervention to inform future research, and plan to use data in support of a future FDA application for the device.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The investigational device is a sleep pad and bedside controller system capable of producing a low-level radio-frequency field potential. An individual laying in the correct orientation and with correct contact distance from the pad portion of a powered device experiences its specific area of effect. The field potentials generated by the pad are hypothesized to have benefit for sleep.
The investigational device is a sleep pad and bedside controller system that produces a low-level radio-frequency field potential. An individual laying in the correct orientation and with correct contact distance from the pad portion of a non-powered device experiences all functional aspects of the device except the intended magnetic field potential that is hypothesized to have benefit for sleep.
Time frame: The later viable night of two recordings: At the end of Phase 1 - Week 2 or Phase 1 - Week 3, and At the end of Phase 2 - Week 2 or Phase 2 - Week 3. Sleep stage minutes (relative to Latency to Persistent Sleep, Edinger et al. 2013).
Quantity of each sleep stage defined by the American Academy of Sleep Medicine (NREM1, NREM2, NREM3, and REM), measured by clinically standard elements of Polysomnography and scored by a Registered Polysomnographic Technologist.
Note: Randomization to Active or Sham during Phase 1 or Phase 2 occurred at the end of Baseline week.
Time frame: The later viable night of two recordings: At the end of Phase 1 - Week 2 or Phase 1 - Week 3, and At the end of Phase 2 - Week 2 or Phase 2 - Week 3. Sleep stage percentage (relative to Latency to Persistent Sleep, Edinger et al. 2013).
Percentage of each sleep stage defined by the American Academy of Sleep Medicine (NREM1, NREM2, NREM3, and REM), measured by clinically standard elements of Polysomnography and scored by a Registered Polysomnographic Technologist.
Note: Randomization to Active or Sham during Phase 1 or Phase 2 occurred at the end of Baseline week.
Time frame: Sum ISI score near end of Phase 1 (study wks2-4) and near end of Phase 2 (study wks6-8).
Self-reported score on the Insomnia Severity Index (ISI; 0-28) e-survey, where a higher score indicates worse/more Insomnia symptoms.
Kunasan Inc.
Industry
Use of the Frequen-ZZZ Sleep Pad to Increase Restorative Sleep: A Proof-of-Concept Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04536766
Dyssomnias, Insomnia
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT03673397
Behavior, Behavioral Symptoms
Sankt Gallen, Switzerland
View Trial DetailsNCT06737055
Behavior, Depression, Postpartum
Providence, Rhode Island, United States
View Trial DetailsNCT04598672
Chronic Disease, Disease Attributes
Oslo, Norway
View Trial Details