Oregon Health and Science University
Portland, Oregon, 97239, United States
NCT Number: NCT02862730
Closed-loop systems are an emerging technology that automate hormone delivery. They are quickly paving the way to revolutionize the treatment of type 1 diabetes. Several categories have emerged: dual-hormone (insulin and glucagon) closed-loop systems and closed-loop systems with insulin only, one variety of which is the low glucose suspend safety feature now available from Medtronic (MiniMed 530G with Enlite). The study described within this protocol is designed to test the efficacy of a new closed-loop algorithm for managing blood glucose in people with type 1 diabetes before and after exercise. The new algorithm will have 3 modes: a single hormone insulin only mode, a dual-hormone insulin and glucagon mode and an insulin only mode with predictive low glucose suspend, all with an exercise detection algorithm. The purpose of this study is to determine whether a dual hormone AP with an exercise detection algorithm outperforms both single hormone AP and a low glucose suspend algorithm and sensor augmented pump therapy using the subject's own insulin pump.
Looking for future studies?
Notify Me21 year–45 year
All sexes
Interventional
Not applicable
Portland, Oregon, 97239, United States
Subjects will undergo four approximately 84 hour studies. The first day of each study will be an approximately 12 hour inpatient visit to include activities of daily living and an exercise period with 2 days spent as an outpatient. The subject will come back to the research center on the fourth day to complete another approximately 12 hour inpatient visit to include activities of daily living and an exercise period followed by removal of all devices. In randomized order, subjects will have glucose controlled using the following systems: 1) dual-hormone closed-loop system, 2) insulin only closed-loop system, 3) predictive low glucose suspend system and 4) sensor augmented pump therapy with subject using their own insulin and insulin pump. Both of the closed-loop system algorithms have an exercise detection algorithm that uses inputs from a heart rate monitor and accelerometer, the Zephyrlife BioPatch. After exercise detection, insulin is turned off for the first 30 minutes, the total insulin infusion rate is adjusted by an exercise multiplier, and for the dual-hormone system, the target glucose for glucagon is increased along with the maximum dose of glucagon allowed. The predictive low glucose suspend system will utilize the patient's optimized basal rates, correction factor, and carb ratio. The patient will bolus for meals and hyperglycemia as usual under PLGS, but will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event. The Dexcom CGM system and the Tandem t:slim pumps will be used for all three intervention visits.
Subjects will arrive at the CTRC at 7am at the start of intervention visits. Subjects will eat breakfast, lunch and dinner in the research center. Subjects will eat breakfast at 8:30am. After breakfast, subjects will complete activities of daily living (sitting on a chair, lying on a bed, washing dishes, sweeping the floor, etc.). Subjects will eat lunch at 12pm. Subjects will exercise for 45 minutes on a treadmill around 2pm. Subjects will eat dinner at 6pm and be discharged. The subject will then go home for Day 2 and Day 3 and return on Day 4 to complete another 12 hour inpatient visit with the schedule of activities identical to Day 1.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin and glucagon delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to two Tandem t:slim insulin pumps, one filled with insulin and one with glucagon.
Other names: APC
Subject will continue on their subcutaneous delivery of insulin on his/her own insulin pump using their own basal rates and carb ratios for meal boluses, managing their blood sugar as they normally would.
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
Time frame: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
Time frame: From 14:00-18:00 for each 12 hour inpatient visit
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
Time frame: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
Time frame: From 14:00-18:00 for each 12 hour inpatient visit
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
Time frame: entire 84 hour study
Assess the mean sensor glucose using Dexcom sensor downloads across all four arms.
Time frame: entire 84 hour study
Assess the number of rescue carbohydrate treatments per day across all four arms.
Time frame: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.0 mmol/L using Dexcom sensor downloads across all four arms.
Time frame: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values greater than 10 mmol/L using Dexcom sensor downloads across all four arms
Time frame: entire 84 hour study
Assess number of events with capillary blood glucose < 3.9 mmol/L using downloads from a Contour Next blood glucose meter across all four arms. .
Time frame: entire 84 hour study
Assess number of events with capillary blood glucose < 3.0 mmol/L using downloads from a Contour Next blood glucose meter across all four arms.
Time frame: 24 hours
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller across all four arms.
Time frame: 24 hours
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller in dual hormone arm.
Oregon Health and Science University
Other
A Randomized, Four-way, Cross-over Outpatient Study to Assess the Efficacy of a Dual-hormone Versus Insulin Alone Closed-loop System With Exercise Detection vs a Predictive Low Glucose Suspend System vs Current Care
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01672255
Autoimmune Diseases, Behavior
Baltimore, Maryland, United States
View Trial DetailsNCT02241889
Autoimmune Diseases, Behavior
Portland, Oregon, United States
View Trial DetailsNCT01897688
Autoimmune Diseases, Diabetes Mellitus
Chicago, Illinois, United States
View Trial DetailsNCT06494722
Autoimmune Diseases, Diabetes Mellitus
Atlanta, Georgia, United States
View Trial Details