NCT Number: NCT01599312
In this randomized crossover trial the investigators test whether three different brands of videolaryngoscopes (VLS) exhibit reduced forces on both upper and lower teeth, and compare them with a classic Macintosh laryngoscope blade.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Eindhoven, North Brabant, 5623 EJ, Netherlands
During endotracheal intubation the anesthesiologist uses a laryngoscope blade to distract the tongue to achieve the best view of the glottis opening, thereby avoiding using the maxillary incisors as a fulcrum to lever the soft tissues upwards. Using the maxillary incisors as a fulcrum may otherwise result in dental trauma. It is obvious that contact with teeth and - even worse - the incidence of accidental dental trauma, is directly related to the difficulty of the intubation.
Indirect videolaryngoscopy has proven advantageous over direct laryngoscopy using a classic Macintosh blade, for improved viewing of the glottis, with subsequent more successful intubations, and a shorter effective airway time both in patients with normal and difficult airways. Previously, it has been demonstrated that the forces exerted by the anesthesiologist on the patient's maxillary incisors are reduced when using a VLS, compared with a classic Macintosh laryngoscope. However, only one type of VLS (V-MAC®, Karl Storz, Tuttlingen, Germany) was used or only forces applied to upper teeth were being registered.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Anesthesia will be induced in the conventional matter. The classic Macintosh laryngoscope will be placed in the patient's mouth and a tube will be brought into position in front of the glottis. Hereafter, one of the three videolaryngoscopes will be placed in the patient's mouth and the endotracheal tube will be actually passed through the vocal cords. The measurement of forces applied to the teeth will be performed using Flexiforce® sensors.
Other names: Macintosh laryngoscope (Karl Storz, Tuttlingen, Germany), McGrath® (Aircraft Medical Ltd, Edinburgh, UK), C-MAC® (Karl Storz, Tuttlingen, Germany), GlideScope® Cobalt (Verathon Medical, Bothell, WA, USA)., Flexiforce® sensors (A201-25, Tekscan, MA, USA)
Time frame: At intubation of the patient
One of the three videolaryngoscopes will be placed in the patient's mouth. The measurement of forces applied to the teeth will be performed using Flexiforce® sensors.
Time frame: At intubation of the patient
Catharina Ziekenhuis Eindhoven
Other
Forces Exerted on Upper and Lower Teeth During Intubation: a Randomized, Cross-over Trial Comparing Indirect Videolaryngoscopy to Direct Videolaryngoscopy.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04827693
Alveolar Bone Loss, Bone Diseases
Los Angeles, California, United States
View Trial DetailsNCT03045185
Dental Pulp Diseases, Endodontically Treated Teeth
View Trial DetailsNCT07611734
Dental Caries, Primary Tooth Restoration
Buraidah, Al-Qassim Region, Saudi Arabia
View Trial DetailsNCT07309653
Behavior, Dental Restoration, Permanent
Bangkok, Thailand
View Trial Details