Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT06671951

Focal Vibration for Enhancing Athletic Speed and Ppower

A focal vibration device will be used to perform an activation and warm-up protocol before performing a set of 7 repetitions of squat with 60% of your 1RM.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year–30 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Study participants must have signed the informed consent form to assess their inclusion in the study.
  • Familiarity with the technique and practice of the weighted free squat.
  • Training at least 3 times per week.

Exclusion criteria

  • Volunteers who have suffered a sports injury during the last two months or are unable to perform physical activity.
  • Have previously received an intervention with focal vibration.
  • Not understanding the information provided by the therapist.
  • Participate in other research studies.
  • Be undergoing pharmacological medical treatment that may interfere with the measurements, such as treatment with anticonvulsants, antidepressants, etc.

Treatment and study plan

Focal Vibration

Other

Focal vibration is a 3x3 electrode placed on the athlete's muscle belly, and emits a high frequency vibration (150Hz) to stimulate the muscle spindle and generate greater muscle activation.

Other names: Local Vibration

Sham focal vibration

Other

Is a focal vibration intervention but without conctact in the athelte's skin. Doing this we got a sham therapy

Primary outcomes

  1. Mean Speed during squat

    Time frame: 1 minute

    A linear transducer (Vitruve VBT) was used to measure the mean speed during the squat. The tether device was attached to the right side of the barbell around the widest part of the collar on the inside and this converts the subject's movement with the barbell into an electrical signal that will record the mean speed and of the exercise. Subjects will per-form 7 repetitions at 0,85 m/s at the maximum possible speed with the optimal load to generate the maximum power.

    Linear transducers which have greater accuracy (5%) and reliability (ICC: 0.752; 95% CI: 0.548 - 0.855) compared to other devices in terms of velocity-based training (VBT) meas-urement.

  2. Mean Power during squat

    Time frame: 1 minute

    A linear transducer (Vitruve VBT) was used to measure the mean power during the squat. The tether device was attached to the right side of the barbell around the widest part of the collar on the inside and this converts the subject's movement with the barbell into an electrical signal that will record the mean power of the exercise. Subjects will per-form 7 repetitions at 0,85 m/s at the maximum possible speed with the optimal load to generate the maximum power.

    Linear transducers which have greater accuracy (5%) and reliability (ICC: 0.752; 95% CI: 0.548 - 0.855) compared to other devices in terms of velocity-based training (VBT) meas-urement.

Secondary outcomes

  1. Scale of perceived effort during squat

    Time frame: 1 minute

    Just after the end of the series of 7 repetitions the sensation of effort perceived by the athlete was measured with the modified BORG scale (0-10), being 0 the lowest perceived effort and 10 being the highest effort.

  2. Participant's rating of clinical change. Global Rating of Change Scale (GROC scale).

    Time frame: 1 minute

    At the end of the free bar squat after the warm-up and the intervention, the subject will be asked if he/she has felt improvement or worsening between the first time and the last time he/she performed the test. The participant's rating of clinical change will be evaluated with a Global Rating of Change Scale (GROC scale). This is a scale of 15 items, of which +7 are improvement and -7 are deterioration, and with 1 central item with no clinical change. Values from the fourth item of improvement or deterioration will be considered clinically significant, values between the three item of improvement and the three item of deterioration will be considered as no clinically significant changes. The test-retest reliability has proven to be good (ICC 0.90).

  3. Muscle Activity

    Time frame: 1 minute

    Surface electromyography was used to evaluate the muscle activity of back and lower limb the during squatting task. The muscles assessed were vastus medialis, vastus lateralis, rectus femoris, biceps femoris, gluteus maximus and erector spinae longissimus. Data were obtained for the dominant limb defined as the one preferred to kick a ball.

    the tool to be used is The mDurance® system (mDurance Solutions SL, Granada, Spain). The RMS was the principal variable recorded for muscle activity, expressed as % of MVIC (%MVIC).

Study contacts

Contact information is provided by the study sponsor or research team.

Max Canet Vintro PT

CONTACT

[email protected]

+34 647267138

Sponsors and collaborators

Lead sponsor

Universitat Internacional de Catalunya

Other

Registry information

Official study title

Effectiveness of Focal Vibration in Enhancing Lower Extremity Speed and Power in Athletes

Important dates

Study start
2024
Primary completion
2024
Study completion
2024
First posted
Nov 4, 2024
Registry last updated
Nov 4, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.