Skip to main content
OpenTrials
Completed

NCT Number: NCT00773721

Foam Mask - Assessment of Bioburden in a New Mask Seal Material

Obstructive sleep apnoea (OSA) is characterised by a partial or complete collapse of the upper airway during sleep. The treatment of choice for OSA is Continuous Positive Airway Pressure (CPAP). CPAP acts as a positive airway splint, delivering a fixed positive airway pressure to the upper airway via a tube and mask. Compliance, however, to therapy requires that the mask is suitably comfortable so as not to disturb sleep.

A key contributor to comfort is the seal component of the mask system. Current mask seals are mainly silicone elastomers, which though well understood and accepted, are often uncomfortable. It is proposed to replace the solid elastomer with a soft polymer foam.

The foam is highly porous, and has open cells at its surface. It is therefore more likely to accumulate biological material with repeated use. The current (silicone) material does not present any problematic bioburden issues. Therefore it is important to investigate whether the foam will present bioburden problems to patients, within specified usage parameters.

The aims of this study therefore are:

1. to observe the rate of bacterial accumulation on foam mask seal material (polyether polyurethane,) 2. to determine the replacement interval for a foam mask seal, and 3. assess the comfort and function of a foam mask seal.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Resmed Centre for Healthy Sleep

Sydney, New South Wales, 2153, Australia

About this study

Test Units: The test unit is a foam seal component which directly replaces the patients existing silicone mask cushion, and is fitted to the patients existing mask frame.

Subjects will wear the test unit mask, instead of the current CPAP mask, each night whilst sleeping. Upon waking, subjects will remove the test unit mask and place it with the skin contact side uppermost on a flat surface adjacent to their bed (e.g. a bedside table). Test unit masks should not be covered, and are to remain exposed to the bedroom environment for the rest of the day. The cycle repeats for up to 35 days (5 weeks).

If necessary, the test can be terminated before this time.

A control group of 2 subjects will wash their test unit mask with only hot water every day for the 5 weeks. Another 4 subjects will have the foam of their test unit mask replaced during the 5 weeks of the trial. Two subjects will have the foam changed after 2 weeks and the other 2 subjects after 4 weeks. This will allow estimations of bioburden after 1,2,3,4 and 5 weeks of use.

The foam samples are to be sealed in the supplied sterile container. The sealed container will be delivered as soon as possible to the project administrator. The project administrator will appropriately collect, record, store, and dispatch the sealed samples for microbiological analysis.

Microbial analysis will determine the number of colony forming units, and species present in each test unit upon test termination.

Skin Reactions:

Participants will be asked to report any skin reaction they experience under the test unit. Subjects will keep a bi-weekly record of any skin redness, irritation, etc.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who are 18+
  • Patients willing to give written informed consent
  • Patients who can read and comprehend English
  • Patients being treated for OSA with CPAP for >6 months
  • Patients using ResMed Masks

Exclusion criteria

  • • Known to have any pre-existing dermatological condition
  • Has been treated with antibiotics in the previous month
  • Any condition which, in the opinion of the investigator, would make the subject unsuitable or unsafe for enrolment, or could interfere with the subject participating in and completing the protocol.
  • Patients currently using ResMed masks: Swift, Activa, or Liberty.

Treatment and study plan

CPAP mask

Device

Current CPAP masks are mainly silicone elastomers, which though well understood and accepted, are often uncomfortable.

Test Units: The test unit is a foam seal component which directly replaces the patients existing silicone mask cushion, and is fitted to the patients existing mask frame.

Subjects will wear the test unit mask, instead of their current CPAP mask, each night whilst sleeping.

Primary outcomes

  1. Measurement of bacterial accumulation in the new material.

    Time frame: up to 35 days (5 weeks).

Sponsors and collaborators

Lead sponsor

ResMed

Industry

Registry information

Official study title

Assessment of Bioburden in a New Mask Seal Material

Important dates

Study start
2008
Primary completion
2008
Study completion
2009
First posted
Oct 16, 2008
Registry last updated
Feb 4, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.