Increased Pacemaker Lower Rate in ATTR Cardiac Amyloidosis
NCT07413081
Amyloid Neuropathies, Amyloid Neuropathies, Familial
Aarhus, Denmark
View Trial DetailsNCT Number: NCT07094217
Conduction system pacing is a new way of stimulating the heart using pacemaker wires. Traditional pacemakers stimulate the heart muscle which causes disordered heart beats: the walls of the heart move at different times. This wears down the heart over time.
Conduction system pacemakers stimulate the heart's electrical system directly producing natural heart beats that are much less disordered. These pacemakers can be challenging to insert with different heart shapes, sizes and scars. This can increase procedure times and time exposed to xray as pacemakers are inserted using x-rays to guide where the lead is implanted.
This study aims to allow conduction system pacemakers to be implanted without the use of normal xray (fluoroscopy).
The investigators will create an anatomical shell of the heart using special plastic (mapping) catheters that is inserted within the heart from the groin. The investigators will use a special heart scanning (echo) catheter to see how the pacemaker wire is inserted into the heart muscle. The investigators will use MRI to confirm that the information we collect is accurate. Using this information the investigators will create a protocol to implant a lead that does not require xray, using only the mapping catheter.
Trial opening soon.
Get Notified18 year–100 year
All sexes
Observational
A total of 75 patients will be recruited for the study
50 patients with a ventricular pacing indication (high grade atrioventricular block and symptomatic trifasicular or bifasicular block) for pacing will be recruited prospectively. The patients will be divided into two groups; 25 patients in the derivation cohort and 25 patients in the validation cohort. The derivation cohort will undergo a detailed research protocol to determine the optimised work flow and this will be applied prospectively to the validation cohort.
The success rates, procedure times, complication rates and fluoroscopy times will be assessed. The 25 patients undergoing conventional methods of conduction system pacing will be recruited as a control arm to compare these outcomes.
In summary, the 75 patients will be grouped as following; 25 patients in the derivation cohort, 25 patients in the validation cohort and 25 patients in the control arm.
Methodology
Derivation The derivation cohort will comprise of 25 prospectively recruited patients. These patients will undergo the research protocol. In these patients, the investigators will attempt to implant a permanent conduction system pacing lead, in lieu of the RV or LV lead. The lead will be implanted by operators who have implanted more than 40 leads to overcome the learning curve.
Pre-implant Prior to the procedure, patients will undergo a clinically indicated Cardiac MRI. The investigators will use these scans to retrospectively assess for the presence of potential mechanisms which could prevent successful lead implantation, such as the presence of septal fibrosis and chamber dimensions, so that we can assess how these can contribute to challenges at the time of implant. We will also be able to review mechanisms for successful implants. This information will be corroborated with data collected from the electro-anatomical maps.
The MRI scans will also be used to merge the anatomical information using CartoMerge to reduce procedure times by building the anatomical geometry prior to the mapping-catheter collecting this information invasively.
During Implant
The participants will undergo the following procedural steps after written informed consent is gained:
This will help determine a few key aspects
The CartoMerge module will be used to expedite anatomical mapping using the MRI data collected.
The information from echocardiography will be corroborated with the lead-septum interaction visualised on electro-anatomical maps created on CARTO.
In this cohort of patients, the conduction system lead will initially pace the His-bundle then the left bundle in order to collect data for both methods of physiological pacing. The information collected from ICE and electro-anatomical mapping will be used to develop a streamlined workflow that will map targeted areas, where challenging implant sites will be rapidly identified (such as areas of scar), reducing the number of attempted lead deployments and visualise lead-septum interaction, apposition and progression, improving safety parameters.
At the end of the procedure, the lead position will be documented with a very short, single fluoroscopic acquisition. This remains integral for future comparison in the instances of lead complications and in particular lead displacement.
Validation
25 patients will be recruited to the validation cohort.
An optimised work flow will be derived using the information collected from the derivation cohort. Namely, the target areas for FAM and electro-anatomical maps will be determined, and the successful pattern of lead septum interaction on CARTO will be defined.
The streamlined workflow will then be applied to 25 prospective patients. The success rates, procedure time, fluoroscopy time, capture threshold, number of attempted lead deployments and complication rates will be assessed.
Control Arm The control arm will consist of 25 patients undergoing a conduction system pacemaker using conventional pacing methods, with the same pacing indications as the study arm.
Follow-up All 75 patients will have standard clinical follow-up at 6 weeks, 6 months and 1 year. The clinical information at these visits will be used to identify complications rates that will include lead displacement, rise in capture threshold and lead injury, device related infections.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: From time of first patient recruited to the last patient recruited in the in the derivation cohort, upto 52 weeks
The primary objective of this study is to develop a fluoroless implant protocol of conduction system leads using 3D electroanatomical mapping. Electroanatomical mapping will be used to understand the cardiac anatomy, removing the reliance on fluoroscopy to position the pacemaker lead. Successful conduction system lead implant rates will be assessed against a control arm utilising conventional fluoroscopic methods.
Time frame: From time of first patient recruited to the time of last patient recruited in the validation cohort upto 52 weeks
Is there a change in the overall procedure and fluoroscopy time with utilisation of targeted lead deployment.
Time frame: From time of first patient recruitment to the 1 year after last patient recruited
With better visualisation of the cardiac anatomy using the electroanatomical mapping, is there a change in complication rates
Contact information is provided by the study sponsor or research team.
Imperial College London
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07413081
Amyloid Neuropathies, Amyloid Neuropathies, Familial
Aarhus, Denmark
View Trial DetailsNCT07352657
Implantable Defibrillator, Pacemaker
Boston, Massachusetts, United States
View Trial DetailsNCT07205679
Ablation Therapy, Arrhythmias, Cardiac
View Trial DetailsNCT07105241
Ablation of Arrhythmias, Arrhythmia
View Trial Details