This study is evaluating a new, noninvasive device designed to detect whether cerebrospinal fluid (CSF) is flowing through a surgically implanted shunt. CSF shunts are commonly used to treat hydrocephalus, but it can be difficult to tell whether a shunt is working properly without invasive testing or imaging that does not directly measure flow.
The study device is a small, wireless sensor placed on the skin over the shunt tubing, typically near the collarbone. It uses gentle, controlled warmth to measure temperature changes that indicate whether fluid is flowing inside the shunt. The device does not break the skin and does not change a participant's medical care.
This study will enroll children and adults who already have a CSF shunt and who do not have new or worsening symptoms of shunt malfunction. All participants will have a measurement taken while their shunt valve is at its usual prescribed setting. Some participants with programmable shunt valves will also have a second measurement taken after their valve is temporarily adjusted to a setting intended to stop or greatly reduce flow ("virtual off"). After this measurement, the valve will be returned to its prescribed setting.
The study device results will not be shown to participants or their medical providers and will not be used to make treatment decisions. The goal of the study is to determine how well the device can distinguish between shunts that are allowing flow and those that are not.
Participants will be monitored for a short period after device use and, if applicable, after any valve adjustment. The main risks of participation are mild skin irritation from the adhesive or temporary symptoms related to valve adjustment. Participants are not expected to receive a direct medical benefit, but the information gained may help improve future diagnosis of shunt function.
Interested in participating?
Request InfoAll sexes
Interventional
Not applicable
Peoria, Illinois, 61602, United States
Location status: Recruiting
This is a prospective, multicenter, open-label, blinded, observational study designed to evaluate the performance of a noninvasive wireless thermal flow detection device for assessing cerebrospinal fluid (CSF) shunt flow in pediatric and adult patients with hydrocephalus.
The study enrolls participants with an existing implanted ventricular CSF shunt who do not have new or worsening symptoms suggestive of shunt malfunction. The investigational device is placed externally on intact skin overlying the shunt tubing, typically near the clavicle, and measures thermal patterns associated with the presence or absence of CSF flow within the shunt catheter. Measurements are obtained using a sponsor-provided tablet application, and results are encoded so that both participants and treating clinicians remain blinded.
All participants undergo at least one device measurement with the shunt valve set to the participant's prescribed flow-permissive ("valve normal") setting. A subset of participants with programmable valves capable of being adjusted noninvasively will also undergo an additional measurement after the valve is temporarily adjusted to a manufacturer-reported "virtual off" setting, defined as a valve opening pressure exceeding 400 mm H₂O. After this measurement, the valve is returned to the prescribed setting, with confirmation using standard valve programming tools.
Participants whose valves are already prescribed at a "virtual off" setting will undergo a single measurement at that setting. A small number of initial roll-in participants are included to refine procedural logistics; their data are not included in the primary endpoint analyses.
The study is non-significant risk. The investigational device does not alter standard-of-care treatment, and device data are not used to guide clinical decision-making. Valve adjustments performed as part of the study are routinely used in clinical care and are monitored closely. Participants are observed for adverse events during device use and for a defined follow-up period after device removal and, when applicable, after valve readjustment.
The primary objective of the study is to assess the ability of the device to distinguish between flow-permissive and non-flowing shunts based on known valve settings. Secondary and exploratory objectives include evaluation of device accuracy metrics and characterization of thermal flow patterns under different conditions, such as posture changes or valve transitions.
Adverse events, including device-related skin findings and any symptoms associated with valve adjustment, are recorded and reported according to protocol and regulatory requirements. Participants exit the study after completion of the measurement(s) and required observation period.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Inclusion and Exclusion Criteria for Roll-In Subjects Inclusion criteria
Inclusion and Exclusion Criteria for Main Study Subjects
Inclusion criteria
Subjects with planned "virtual off" measurement:
-Existing ventricular CSF shunt with an available "virtual off" setting which can be programmed noninvasively
Subjects with planned adjustment to the "virtual off" setting only:
-Subject-reported or documented history of successful valve adjustment(s)
Exclusion criteria
Exclusion criteria
Exclusion criteria
for Main Study Subjects Exclusion criteria
Subjects with planned "valve normal" measurements:
characters, and fully aligned with your protocol: The intervention consists of use of a noninvasive, wireless thermal flow detection device to assess cerebrospinal fluid (CSF) flow in an existing implanted shunt. The device is externally applied to intact skin over the shunt tubing, typically near the clavicle, and delivers controlled, imperceptible thermal energy while measuring resulting temperature gradients associated with CSF flow. Measurements are performed using a sponsor-provided tablet application that encodes results to maintain blinding. In some participants with programmable shunt valves, measurements are obtained under both prescribed flow-permissive settings and a temporary manufacturer-reported "virtual off" valve setting, after which the valve is returned to the prescribed setting. Device data are collected for research purposes only and are not used to guide clinical care.
Time frame: Day 1
Evaluation of sensitivity and specificity using the main study data
Contact information is provided by the study sponsor or research team.
Rhaeos, Inc.
Industry
Detection of Flow in Cerebrospinal Fluid Shunts With a Wireless Thermal Flow Detection Device During Open and Closed Shunt Periods
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07050628
Brain Diseases, Central Nervous System Diseases
Chicago, Illinois, United States
View Trial DetailsNCT06253858
Brain Diseases, Central Nervous System Diseases
Hershey, Pennsylvania, United States
View Trial DetailsNCT05910944
Brain Diseases, Central Nervous System Diseases
Kuopio, Finland
View Trial DetailsNCT06724029
Aneurysm, Aneurysms
Bergamo, BG, Italy
View Trial Details