Skip to main content
OpenTrials
Completed

NCT Number: NCT02161029

Flexible Endoscopy Biopsies for Submucous Tumors With a New Drill Instrument

The purpose of this study is to determine whether the newly constructed CE (Conformité Européenne) marked drill biopsy instrument for flexible endoscopes can make possible representative biopsies of the increasing numbers of submucosal tumours in the gastrointestinal tract. The amount of submucous tissue ( micrograms and in % of all the biopsy) harvested with the new drill biopsy instrument used in flexible endoscopy investigations is measured in the study and compared to the amount of submucous tissue harvested with the existing biopsy forceps.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Department of Surgery, Lund University

Lund, SE-22185, Sweden

About this study

Background: With the existing biopsy instruments for flexible endoscopy it's only possible to achieve superficial biopsies comprising the mucosa and very seldom some small fragments of the submucosa. It is, however, increasingly important to get biopsies from the submucous tissues because the tumors that are on the increase more than any other in the stomach is the GIST (GastroIntestinal Stroma Tumours) that grows in the submucosa. Cytology is not enough for a reliable diagnosis and to often not representative. Furthermore there is a well-known risk for tract seeding when sampling through the abdominal wall with a fine needle instrument.

The investigators have invented a new biopsy instrument for flexible endoscopy that is a drill within a cylinder that can be used for biopsies of the submucous tissues, for instance GIST-tumours, see www.BIBBInstruments.com.

Hypothesis: Will it be possible to achieve representative submucous tissue from the gastrointestinal tract with the newly constructed drill biopsy instrument for flexible endoscopy. The investigators hypothesize that the amount of tissue harvested with the new drill biopsy instrument will give significantly more amount of tissue to evaluate for the pathologist than the existing biopsy forceps.

Method: Ten patients with tumours in the submucosa of the stomach are examined with a gastroscope. The investigator decides where the first biopsy should be taken and randomly the investigator blindly get the new drill instrument or the conventional biopsy forceps and take the biopsy on the decided localization. The next site of the tumour is decided and again blindly the investigator get one of the two biopsy instruments according to a previously decided scheme. Six biopsies (three with each of the two biopsy tools) in every patient are harvested in ten patients. With altogether 30 specimen for each biopsy instrument and a difference of 1/3 which is a low calculated difference 10 patients as above will give a 80 % Power (Chi-2 = 5.40, p = 0.02*). The amount of submucous tissue harvested with the two biopsy instruments are measured in microgram and as percentage of all the biopsy and compared. The quality of the specimens are also calculated.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Submucous gastrointestinal tumours

Exclusion criteria

  • No gastrointestinal submucous tumor
  • Submucosal hemangioma

Treatment and study plan

Flexible drill biopsy instrument

Device

Biopsies taken with the new drill biopsy instrument for flexible endoscopy

Other names: Endodrill (=Internal code name)

conventional biopsy instrument

Device

Biopsies taken with conventional biopsy forceps for flexible endoscopic instruments

Primary outcomes

  1. Amount of submucous tissue in gastrointestinal submucosal tumors harvested with a new drill biopsy instrument used with flexible endoscopes.

    Time frame: Within 30 days for each patient

    Amount of submucous tissue adequate for histological examination harvested with the new drill biopsy instrument for flexible endoscopy and compared to the amount harvested with the existing biopsy forceps in a randomized setting.

Sponsors and collaborators

Lead sponsor

Region Skane

Other

Collaborators

  • Lund University
  • Lund University Hospital

Registry information

Official study title

Flexible Endoscopy Biopsies With the New Drill Biopsy Instrument for Submucous Tumors

Important dates

Study start
2014
Primary completion
2015
Study completion
2015
First posted
Jun 11, 2014
Registry last updated
Feb 1, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.