Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf
Hamburg, 20246, Germany
NCT Number: NCT06602089
This is an observational study simultaneously comparing finger-sensor and oscillometric with intra-arterial blood pressure measurements in patients having low- to moderate-risk non-cardiac surgery.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Hamburg, 20246, Germany
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
We will record intraarterial arterial pressure, finger-sensor arterial pressure and oscillometric arterial pressure in all included patients.
Time frame: During surgery
To investigate whether the agreement between finger-sensor arterial pressure measurements and intraarterial arterial pressure measurements (mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure) is better than the agreement between oscillometric arterial pressure measurements and intraarterial arterial pressure measurements, we will perform Bland-Altman analyses.
Time frame: During surgery
To classify measurement differences (mean arterial pressure and systolic arterial pressure) between finger-sensor arterial pressure measurements and intraarterial arterial pressure measurements according to their clinical importance, we will perform error grid analyses.
Time frame: During surgery
To classify measurement differences (mean arterial pressure and systolic arterial pressure) between oscillometric arterial pressure measurements and intraarterial arterial pressure measurements according to their clinical importance, we will perform error grid analyses.
Time frame: During surgery
To investigate the ability of finger-sensor arterial pressure monitoring to track arterial pressure changes (mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure) compared to intraarterial arterial pressure monitoring, we will compute four-quadrant plots and calculate the concordance rate.
Time frame: During surgery
To investigate the ability of oscillometric arterial pressure monitoring to track arterial pressure changes (mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure) compared to intraarterial arterial pressure monitoring, we will computer four-quadrant plots and calculate the concordance rate.
University of Hamburg-Eppendorf
Other
Finger-sensor and Oscillometric Versus Intra-arterial Blood Pressure Measurements: a Method Comparison in Patients Having Non-cardiac Surgery
Acronym: PERCEPTION
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04817137
Blood Pressure
Boston, Massachusetts, United States
View Trial DetailsNCT07713576
Blood Pressure
Chenzhou, Hunan, China
View Trial DetailsNCT06550297
Blood Pressure, Cardiovascular Diseases
New York, United States
View Trial DetailsNCT07317648
Blood Pressure
York, England, United Kingdom