Department of Neuro-urology, Tenon hospital
Paris, 75020, France
NCT Number: NCT03255421
This study evaluate the feasibility and the accuracy of an emptying cystometry in order to simplify the manometric follow-up of overactive detrusor in neurological patients under anticholinergic or botulinum toxin injections.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Paris, 75020, France
Bladder pressure assessment is necessary for the diagnosis, the prognostic assessment and the management of neurogenic bladder. High bladder pressures increase the rate of urological complications and mortality in patients with neurogenic bladder. Thus many treatments are proposed in order to improve bladder compliance and reduce uninhibited detrusor contractions (anticholinergic drugs, botulinum toxin injections, cystoplasty, sacral neuromodulation, beta-3-agonist, posterior tibial nerve stimulation).
Clinical data, symptoms scales, quality of life questionnaires, renal ultrasound, biological tests of renal function and urodynamic studies are used to control the treatment efficacy of neurogenic lower urinary tract dysfunction. Filling cystometry is the usual way to record bladder pressure. Urodynamic techniques using external pressure transducers (microtip, air-filled or fluid-perfused catheters) connected to the patient with fluid-filled lines are recommended. This multichannel cystometry is performed in a specialized department with the inconvenience of delays for appointments and cost of the urodynamic assessment. Moreover, only some parameters are important and are taken in account in the follow-up of these neurogenic bladders: bladder capacity, bladder compliance and maximum detrusor pressure at the end of the filling phase. All these parameters can be recorded with a self-assessment of bladder pressure at home with a very simple device made of 1) a self-intermittent catheter; 2) a three way stopcock; 3) a simple graduated tube. This device has in fact been used in the past to realize cystometries, in particular in the elderly subject. A such device should provide a monitoring in changes in bladder pressure in order to initiate adjustments in treatment sooner than would be achieved when patients are evaluated periodically but less frequently in the neurourology department. The early detection of high bladder pressures may avoid bladder deformation, reflux and upper tract deterioration. Moreover, the home control of appropriate bladder pressure may improve the patients' quality of live by reducing the constraint linked to the time-consuming specialized follow-up.
In this study, the investigators will test a reverse single channel cystometry performed just after a classical filling cystometry during the usual emptying by means of a device allowing serial bladder pressure measurements during the bladder emptying. In case of such a feasibility and a good precision of the reverse cystometry, the manometric follow-up of overactive detrusor in neurological patients under anticholinergic or botulinum toxin injections could be simplified.
The aim of this study is to assess the feasibility and the accuracy of sequential measurements of bladder pressure during the bladder emptying and to compare the evolution of bladder pressures during the emptying phase with the bladder pressures recorded during the filling phase.
Patients over 18 years old, consulting for lower urinary tract symptoms and performing an urodynamic examination with a cystometry in a tertiary center are included.
History, treatment and urodynamics data are recorded. Conventional supine multichannel cystometry with isotonic saline infused at 50ml/min (filling cystometry), conform to the International Continence Society (ICS) recommendations will be performed. At the end of the standard cystometry when the maximum cystometric capacity will be reached, if no micturition was obtained, urodynamic catheter was withdrawn and a CH12 urinary catheter will be introduced in the bladder according to the usual department procedure (usually, this catheter allows to empty the bladder). This catheter will be connected to a three-way stopcock. The second way of the stopcock will permit the emptying into a measuring container, graduated each 50ml. The third way of the stopcock will be connected via a tube extension to a rigid vertical 70cm tube (central venous pressure set) graduated each centimeter. The zero pressure of the vertical tube will be set at the upper edge of the symphysis pubis. For measuring the bladder pressure at the maximum cystometric capacity, the valve will be open between the bladder and the graduated tube, manometric data will be derived by observing the rise of the column of fluid in the centimeter scale tube. This procedure will be repeated every 50ml until bladder full emptying.
The investigators will compared each bladder pressure measures every 50ml during the "backwards cystometry" with each bladder pressure measured every 50ml from the maximum capacity during the filling cystometry.
Primary outcome is the agreement between the two cystometries evaluated using a kappa coefficient.
Secondary outcome is the correlation between the pressures during the two cystometries.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Observational study No intervention, only fragmenting the emptying of the bladder
Time frame: 1 Day : during the urodynamic assessment
Agreement between the two cystometries evaluated using a kappa coefficient.
Time frame: 1 Day : during the urodynamic assessment
Correlation between the pressures during the two cystometries.
Pierre and Marie Curie University
Other
Filling and Emptying Cystometries: a Feasibility and Validation Study in Order to Simplify the Manometric Follow-up of Overactive Detrusor in Neurological Patients Under Anticholinergic or Botulinum Toxin Injections.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04557748
Female Urogenital Diseases, Female Urogenital Diseases and Pregnancy Complications
Chicago, Illinois, United States
View Trial DetailsNCT07715448
Benign Prostatic Hyperplasia, Ejaculatory Dysfunction