Skip to main content
OpenTrials
Completed

NCT Number: NCT01695265

Feel Breathe, Restriction Device Ventilatory Nasal (COPD)

FEELBREATHE®, a nasal ventilatory restriction device, used during an exercise test in treadmill produces changes on breathing efficiency in patients with Chronic Obstructive Pulmonary Disease (COPD). 20 men with COPD with a forced expiratory volume in the first second between 30% and 70% of its predicted value were selected. Then, a maximal incremental cardiopulmonary exercise test was performed to determine ventilatory and cardiac parameters. During the second day, each participant conducted two tests with 30 min of rest between them. Exercise protocol was an identical walk on a treadmill for 10 minutes at a constant rate at 50% of VO2peak. Each test was performed randomnly in two different conditions: 1) oronasal breathing (ONB); and 2) nasal breathing through the FB.

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–70 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Centro Andaluz Medicina del Deporte

San Fernándo, Cádiz, 11100, Spain

About this study

Rationale: A device called FeelBreahte (FB)® has been designed, developed and patented for inspiratory muscle training in dynamic situations.

Objetive: To examine the effects of FB on lung ventilation, gas exchange and heart rate during exercise in patients with COPD.

Methods: 20 men with COPD with a forced expiratory volume in the first second between 30% and 70% of its predicted value were selected. In the first visit to the laboratory, baseline static maximum inspiratory pressure and spirometry were performed previous to the exercise. Then, a maximal incremental cardiopulmonary exercise test was performed to determine ventilatory and cardiac parameters. During the second day, each participant conducted two tests with 30 min of rest between them. Exercise protocol was an identical walk on a treadmill for 10 minutes at a constant rate at 50% of VO2peak. Each test was performed randomnly in two different conditions: 1) oronasal breathing (ONB); and 2) nasal breathing through the FB.

Results: Lung ventilation and gas exchange during exercise in COPD patients was modified during exercise using FB. Our results showed a positive effects of FB vs ONB on dynamic hyperinflation, an improved breathing pattern and breathing efficiency, higher expiratory and inspiratory time and higher perceived effort. Despite these differences, blood oxygen saturation percentage, oxygen uptake and heart rate showed similar response between both conditions.

Conclusions: The new device FB used during exercise in COPD patients influenced ventilatory responses to an efficiency breathing compared to oronasal mode.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Patients diagnosed of Chronic Obstructive Pulmonary Disease (COPD) at least 6 months before, with a forced expiratory volume in the first second (FEV1) between 70 and 30% of predicted value

Exclusion criteria

  • Suffer other illness.
  • Unwillingness to complete the study requirements.
  • Cardiovascular diseases (resting electrocardiogram and during exercise).
  • Elevated resting blood pressure (>130/85 mmHg). All inclusion and exclusion criteria were assessed by a detailed medical history and, where noted, by specific measurements.

Treatment and study plan

Exercie oronasal breathing (ONB)

Other

10 min at 50% of VO2 Peak achieve during a first incremental cardiopulmonary exercise test CPET using oronasal breathing (ONB)

Exercie nasal breathing through the FB

Device

Device: Feel Breathe, restriction device ventilatory nasal The Feel Breathe (FB) consisted of a small adhesive strip that is place across the bridge of the nose during exercise. The FB was place following procedures for placement as indicated by the manufacture's directions, while the placebo nasal, was placed over the nostrils of the subject, without interfering nasal breathing; thus, nasal airflow resistance was not increase. 10 min at 50% of VO2 Peak achieve during a first incremental cardiopulmonary exercise test CPET using FeelBreathe device (FB)

Primary outcomes

  1. Overall impact of a restriction device ventilatory nasal over different physiological variables in COPD

    Time frame: Subjects were assessed during 8 weeks

    The investigators measure minute ventilation, peak oxygen uptake (VO2p), peak carbon dioxide production (VCO2p), breathing frequency (BF), ventilatory equivalent for carbon dioxide (CO2 Eq), ventilatory equivalent for oxygen (Eq O2), expiratory tidal volume (Vtexp), inspiratory tidal volume (Vtins), end-tidal carbon dioxide tension (PETCO2), end-tidal oxygen tension (PETO2), inspiratory time (T.in), ratio of inspiratory duration to total breath duration (ti/t), expiratory time (Tex), oxygen saturation measure by pulse-oximetry SpO2), heart rate (HR), duration of the test and dyspnea and leg fatigue measures by Borg scale. Each subject performed two identical submaximal exercises at 50% of VO2peak under different breathing conditions: 1) nasal breathing with FB and 2) oronasal breathing without FB. Incremental exercise tests were performed on a treadmill ergometer using a one minute step protocol to a symptom-limited maximum.

Secondary outcomes

  1. Maximal Oxygen uptake

    Time frame: Subjects were assessed during 8 weeks

    Before experimental trials each subject performed an incremental protocol on a treadmill ergometer (MONARK, Hamburg, Germany) for the determination of gas exchange. The test was stopped upon volitional fatigue of the subject. Gas-exchange data were measured breath by breath using an Oxycon cardiopulmonary exercise system (Jaeger, Hoechberg, Germany).

  2. Maximum static inspiratory pressure (PImax)

    Time frame: Subjects were assessed during 8 weeks

    Inspiratory muscle testing was performed using a mouth pressure meter (Micro Medical Inc., Chatham, Kent, UK). The manufacturer states that the test-retest reliability of this device is ±3%. PImax was measured at residual volume and the best result from three inspiratory attempts was taken. Al least one minute was allowed between attempts to minimize the effects of muscle fatigue.

Sponsors and collaborators

Lead sponsor

University of Cadiz

Other

Collaborators

  • European Regional Development Fund

Registry information

Acronym: BreatheCOPD

Important dates

Study start
2012
Primary completion
2012
Study completion
2015
First posted
Sep 27, 2012
Registry last updated
Jun 4, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.