NCT Number: NCT01608529
It has patented a restriction and filtering device ventilatory nasal flow FeelBreathe with the aim of increase nasal airflow resistance, therefore the objective was to examine the effects of FeelBreathe with lung ventilation and gas exchange during exercise.
Looking for future studies?
Notify Me25 year–35 year
Male
Interventional
Phase 1
San Fernando, Cadiz, 11100, Spain
Background: Different devices are currently used to train inspiratory muscles, thus showing an increase in the physical performance. It is a control trial to investigate the effects of a new restriction and filtering device ventilatory nasal flow (FeelBreathe).
Methods: A total of 27 trained male caucasian subjects (age: 32.5 ± 7.23 years) were recruited from different sports clubs. Measurement of maximum static inspiratory pressure were taken before exercise testing and an incremental test in cycle ergometer to volitional fatigue for the determination of gas exchange data. Each subject performed three identical submaximal exercises at 50% of ventilatory thresholds under different breathing conditions: 1) oronasal breathing 2) nasal breathing and 3) nasal breathing with Feel Breathe, Restriction and Filtering Device Ventilatory Nasal Flow.
Discussion: Researchers try to find if the new device called FeelBreathe causes changes in the lung ventilation and gas exchange during exercise. If the results show altered breathing pattern and cardiometabolic variables, FeelBreathe could be used to training respiratory muscles.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Feel Breathe (FB) consisted of a small adhesive strip that is placed across the bridge of the nose during exercise. The FB was place following procedures for placement as indicated by the manufacturer's directions, while the placebo nasal, was placed over the nostrils of the subject, without interfering nasal breathing; thus, nasal airflow resistance was not increase. Each subject was required to perform three identical submaximal exercises with intensity at 50% VT1-VT2 under different breathing conditions. The breathing conditions were: oronasal, nasal and FB breathing. All participants performed three trials of stable load (50% VT1-VT2) for 10 minutes in the three conditions mentioned above, setting the cadence at 70-75 rpm, and controlling the same in all three exercise conditions.
Other names: Restriction device ventilatory nasal. PCT/ES2010/000429., Feel Breathe. Registro: N0299875-0.
Time frame: Subjects were assessed during 8 weeks
VE (l/min), Vtin (ml/kg), BF (bf/min), VCO2 (ml/min), VE/VO2 (ml), VE/VCO2 (ml), RER (VCO2/VO2), PETO2 (mmHg), PETCO2 (mmHg), tin (s/insp), tex (s/expir), Vtin (ml/min), Vtex (ml/min), SPO2 (%) and VO2 (ml/kg/min) were assessed throughout the exercise on a cycle ergometer (ERGO-Line GmbH + CoKG, mod. Jaeger ER-900. Germany) using three different conditions of breathing: oronasal, nasal and nasal breathing with FeelBreathe, with 10-sec sampling intervals using a open circuit spirometry (CPX Cardinal Health, 234 GmbH, Leibnizstrasse 7, D-97204 Hoechberg, Germany).
Time frame: Subjects were assessed during 8 weeks
Before experimental trials each subject performed a incremental protocol on a cycle ergometer (ERGO-Line GmbH + CoKG, mod. Jaeger ER-900. Alemania) for the determination of gas exchange. The test was stopped upon volitional fatigue of the subject gas-exchange data were measured breath-by-breath using open circuit spirometry (CPX Cardinal Health, 234 GmbH, Leibnizstrasse 7, D-97204 Hoechberg, Alemania).
Time frame: Subjects were assessed during 8 weeks
Inspiratory muscle testing was performed using a mouth pressure meter (Micro Medical Inc., Chatham, Kent, UK). The manufacturer states that the test-retest reliability of this device is ±3%. Maximum static inspiratory pressure was measured at residual volume and the best result from three inspiratory attempts was taken. At least one minute was allowed between attempts to minimize the effects of muscle fatigue.
University of Cadiz
Other
Phase 1: Effects of a Restriction Device Ventilatory Nasal Flow on Pulmonary Ventilation and Gas Exchange During Exercise
Acronym: FB
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06797089
Apnea, Daytime Sleepiness
Dallas, Texas, United States
View Trial DetailsNCT06887660
Mouth Breathing, Pathological Conditions, Signs and Symptoms
Pavia, Lombardy, Italy
View Trial DetailsNCT01962766
Atypic Swallowing, Low Resting Position of Tongue
Montreal, Quebec, Canada
View Trial DetailsNCT04876625
Apnea, Dyssomnias
Dallas, Texas, United States
View Trial Details