Skip to main content
OpenTrials
Completed

NCT Number: NCT03498027

Febrile Whole Blood Specimen Collection and Testing

Whole blood samples will be collected from febrile patients presenting with fever of unknown origin and flu-like syndromes. Collection sites will consent patients and collect one (1) 4 mL whole blood sample from adults and either (1) 2 mL pediatric whole blood sample or 0.5 mL whole blood sample collected in a micro collection container from pediatric patients from each patient enrolled into the study. Study site will test whole blood samples received from collection sites daily using the Applied Biosystems™ Bacillus anthracis Detection Kit. Data generated will demonstrate product specificity when testing febrile whole blood samples.

Completed

Looking for future studies?

Notify Me

Key information

Age range

2 year–89 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Boca Biolistics, Tarpon Springs, Florida, United States

Loading trial locations.

About this study

Whole blood samples will be collected from febrile patients presenting with fever of unknown origin and flu-like syndromes. Collection sites will be advised of collection requirements specific to patient population with the goal of collecting samples form patient between the ages of 2-89 years of age. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor. Samples must be shipped to MRIGlobal or designated study site on the day of collection.

Collection sites will consent patients and collect one (1) 4 mL whole blood sample from adults and either (1) 2 mL pediatric whole blood sample or 0.5 mL whole blood sample collected in a micro collection container from pediatric patients (anticoagulant: K2EDTA or defined alternative) from each patient enrolled into the study. Patients may not be enrolled in the study more than once. Patients considered for enrollment will be logged on an enrollment log. Log must be reviewed by the site prior to considering a patient for study enrollment to confirm enrollment status. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor.

Study site will accept or reject samples based on shipping verification procedures and then process samples acceptable for testing within 24 hours of receipt. Sample testing must be performed in accordance with the Applied Biosystems™ Bacillus anthracis Detection Kit instructions for use.

At study start, study site will test whole blood samples received from collection sites daily (e.g. Tuesday, Wednesday, Thursday, and Friday) using the Applied Biosystems™ Bacillus anthracis Detection Kit. No reference testing will be required since the study is designed only to demonstrate product specificity. Samples are assumed to be negative for Bacillus anthracis. A minimum of 50, but likely 100 febrile whole blood samples will be tested at MRIGlobal.

Data generated will demonstrate product specificity when testing febrile whole blood samples.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Fever

Exclusion criteria

  • None

Treatment and study plan

TaqMan Bacillus anthracis Detection Kit

Device

The TaqMan® Bacillus anthracis Detection Kit is composed of the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software, secondary interpretative software, and lyophilized reagents for the detection of gene targets for B. anthracis. The test assay is a multiplexed assay targeting gene targets for B. anthracis, in addition to an internal positive control. Reagents are lyophilized as a fully formulated Mastermix and are stable at room temperature for up to two years. The kit is specifically designed for performing real-time PCR using the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software , with nucleic acids extracted from clinical specimens using Qiagen's QIAamp® Blood Midi Kit manual extraction or Roche MagNAPure automated extraction methods.

Primary outcomes

  1. Product Specificity

    Time frame: 1 day

    Data generated will demonstrate product specificity when testing whole blood samples.

Sponsors and collaborators

Lead sponsor

MRI Global

Industry

Collaborators

  • Department of Health and Human Services

Registry information

Official study title

Febrile Whole Blood Specimen Collection and Testing Protocol to Demonstrate Product Specificity for the Applied Biosystems™ Bacillus Anthracis Detection Kit

Important dates

Study start
2018
Primary completion
2018
Study completion
2018
First posted
Apr 13, 2018
Registry last updated
Dec 19, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.