Sansum Diabetes Research Institute
Santa Barbara, California, 93105, United States
NCT Number: NCT01987206
The goal of this proposed study is to explore the feasibility of using a PID (Proportional-Integral-Derivative) controller versus an MPC (Model Predictive Control) controller algorithm in an artificial pancreas system, all other components and study design being equal.
The study consists of an evaluation of either type of control algorithm as a part of the Artificial Pancreas (AP) device during two periods of 27.5-hour closed-loop control in a clinic environment (Sansum Diabetes Research Institute, Santa Barbara, CA) separated by a minimum of 5 days and a maximum of 2 weeks. The 27.5-hour period includes: 2 announced meals (dinner and breakfast of 65g and 50g CHO respectively) preceded with a dose of rapid-acting insulin equivalent to 100% bolus based on each subject's Insulin to Carbohydrate (I:C) ratio and 1 unannounced meal (lunch of 65g carbohydrates, same meal content as dinner); complete night from 12:00 am to 7:00 am. The goal is to demonstrate that the AP device is able to maintain the subject blood glucose within a safe range at all times.
Looking for future studies?
Notify Me21 year–65 year
All sexes
Interventional
Early Phase 1
Santa Barbara, California, 93105, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 24-hour closed loop
The percentage of time spent in safe blood glucose range of [80-140] mg/dl will be the primary endpoint. More time spent inside the desired range will be considered successful. Expected levels are [70-180] mg/dl in the 5 hours after meals.
Time frame: 24-hour closed loop
The secondary endpoint measures glucose extremes and the need for outside intervention to prevent hypoglycemia or hyperglycemia. Interventions would be insulin injections or oral carbohydrates given to the subject by the physician. No need for physician intervention will be considered a successful outcome.
Sansum Diabetes Research Institute
Other
Feasibility Study of Using a PID (Proportional-Integral-Derivative) Controller Versus an MPC (Model Predictive Control) Controller Algorithm and Health Monitoring System (HMS)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07696039
Autoimmune Diseases, Diabetes Mellitus
Bergamo, Italy
View Trial DetailsNCT03263494
Autoimmune Diseases, Diabetes Mellitus
Los Angeles, California, United States
View Trial DetailsNCT07090824
Autoimmune Diseases, Diabetes Mellitus
Palo Alto, California, United States
View Trial DetailsNCT05211479
Adolescent, Anxiety Disorders
Yalova, Turkey (Türkiye)
View Trial Details