Institut für Diabetes-Technologie
Ulm, Baden-Wurttemberg, 89081, Germany
NCT Number: NCT05133973
A single centered, prospective, double blinded study enrolling 12 Type I diabetic patients (+ up to 4 replacements) in two cohorts. Patients will wear multiple FiberSense CGM systems for 28 days, with total duration of the participation up to 8 weeks (screening + active phase + follow up).
The primary aims of the study are assessment of the safety and tolerability of the FiberSense CGM system during the wearing time together with characterization of the system performance when compared to capillary blood samples.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Ulm, Baden-Wurttemberg, 89081, Germany
The FiberSense system is intended to be used by diabetic patients in a home use setting as a CGM system using the interstitial fluid (ISF) glucose as an indicator of blood glucose levels.The purpose of this study is to assess the performance of FiberSense system across the glucose measurement ranges as compared with a laboratory standard reference method in diabetic patients (Type I) during in-clinic glucose challenge sessions. At the same time and also at home use the blood glucose values are recorded by comparator system and self-monitoring blood glucose system (SMBG). The safety aspects are also investigated during the wearing time of 28 days.
The two cohorts differ in the measurement scheduled, with intensive measurement week either at week 1 (cohort A) or week 2 (cohort B).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
FiberSense system, a novel CGM system, based on a fiber-optical sensor placed through the dermis of the patient.
Time frame: 6 measurements within 28 days
Point accuracy of the FiberSense system as determined by proportion of CGM readings within ≤15% of the LGSR reading for blood glucose levels >100 mg/dl, and within ≤15 mg/dl of the LGSR reading for blood glucose levels ≤100 mg/dl (15/15%), for paired samples taken during the in-clinic sessions.
Time frame: 28 days
Incidence of reported ADE with focus on number of patients experiencing serious ADE, evaluated according Draize's scale (0 to 4 - for none to severe findings)
Time frame: 6 measurements within 28 days
The percentage of FiberSense CGM system readings within metrics 20/20%, 30/30%, 40/40% and greater than 40% of the laboratory reference values
Time frame: 6 measurements within 28 days
Analyze the proportion of readings in each region of two Grids. Readings in various regions are considered from clinically accurate or with clinically acceptable accuracy to inaccurate to various degrees.
Time frame: 6 measurements within 28 days
Mean and Median Absolute Relative Differences (MARD, MedRD) of FiberSense measured glucose from laboratory reference values, evaluated at various glucose dynamics
Time frame: 6 measurements within 28 days
Performance of FiberSense System evaluated as percentage of system readings within 15%, 20%, 30% and 40% of SMBG values
Time frame: 6 measurements within 28 days
Precision Absolute Relative Difference (PARD) of two simultaneously worn FiberSense Systems by one patient, for same body parts and two different insertion sites
Time frame: weekly during 28 days
Percentage of FiberSense System readings within various % of the LGSR values
Time frame: 28 days
Duration of use of the individual FiberSense devices
Time frame: after 28 days
Subjective impression of the patients assessed by 5-point Likert scale (1 - strongly agree to 5 - strongly disagree)
EyeSense GmbH
Industry
Effectiveness and Safety Study to Investigate the Improved FiberSense Continuous Glucose Monitoring System in Diabetic Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00837122
Cardiovascular Diseases, Diabetes
Accra, Ghana
View Trial DetailsNCT03899883
Diabetes, Diabetes Complications
Aurora, Colorado, United States
View Trial DetailsNCT00065676
Body Weight, Diabetes
Bethesda, Maryland, United States
View Trial DetailsNCT00862433
Body Weight, Diabetes
Bethesda, Maryland, United States
View Trial Details