NCT Number: NCT02033343
The purpose of this study is to monitor movement of the prostate during radiotherapy and adjust the radiation beam to account for any motion seen. This will increase the radiation dose to the prostate and decrease the dose to the rectum and bladder.
Looking for future studies?
Notify Me35 year–85 year
Male
Interventional
Not applicable
St Leonards, New South Wales, 2065, Australia
Prostate cancer now accounts for one third of all new cancer diagnoses in men and approximately 30% of men will have external beam radiotherapy as their primary local therapy. Prostate motion during radiotherapy can be divided into interfraction and intrafraction motion. Interfraction motion has been well established and has been largely overcome by daily online image verification with either ultrasound, online CT or implanted fiducial markers, however motion during the radiation beam on time (intrafraction motion) is not corrected and can be the cause of significant errors in radiation dose delivery.
The most common technology utilised in 2012 to allow prostate gating is the Calypso system. The Calypso system consists of implantable electromagnetic transponders, an array that contains source and receiver coils, computers for data analysis and display purposes, and an infrared camera system to localise the electromagnetic array in the treatment room. The array is placed over the patient, and the source coil in the array emit an electromagnetic signal that excites the transponders. Once the transponders are excited, the source coils are turned off and the receiver coils detect the signal emitted from the excited transponders. This process is repeated at a rate of 10 Hz, providing a realtime radiofrequency localisation of the prostate triangulating three implanted beacons. The current study will investigate using the continuous prostate positioning data from Calypso to integrate with the treatment beam delivery and allow real-time adaptation based on the prostate motion. This is called Realtime Dynamic Multileaf Collimator (DMLC) tracking. In this technique the multileaf collimator motion is altered in the gantry head in real time during beam delivery to account for the measured prostate motion.
The proposed study is examining the dosimetric impact of accounting for intrafraction motion with Calypso and DMLC tracking. We hypothesise the improvements in delivered prostate dose with DMLC tracking will be even greater than gating. This improved treatment delivery will ensure that the prostate cancer receives the appropriate dose and that normal tissues are spared from extra radiation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Radiotherapy delivered using Calypso radiofrequency emitting beacon guided real-time prostate localisation and beam adjustment using Dynamic Multi-leaf Collimator tracking software.
Time frame: 2 years
The primary endpoint of this Pilot study is to evaluate the feasibility of implementing realtime adaptive radiotherapy using DMLC. This will be assessed as greater than 95% of fractions being successfully delivered (no equipment failures and tracking MLC follows beacons) with Calypso-guided tracking.
Time frame: 2 years
Geometric alignment will be measured as average difference between beacon centroid and shifted MLC against original MLC.
Time frame: 2 years
Dosimetric improvement will be assessed by applying the methods of Poulsen to reconstruct delivered dose distributions for each fraction of patient cohort and summed total dose. Preliminary data demonstrates dose reconstruction to follow the planned dose distribution, potentially even for ultrahypofractionated cases with longer treatment duration and Flattening Filter Free (FFF) delivery with larger potential delivery error per time increment.
Time frame: Assessed up to 12 weeks post treatment
Portion of patients with grade 3 or greater genitourinary or gastrointestinal toxicity assessed using the Modified Radiation Therapy Oncology Group (RTOG) Toxicity Scale.
Time frame: Up to five years
Ongoing reporting of gastrointestinal and genitourinary toxicity of the DMLC tracking cohort will be compared to matched pair controls using the modified RTOG scale.
Time frame: Up to five years
Ongoing biochemical control of the DMLC tracking cohort will be compared to matched pair controls using Prostate Specific Antigen (PSA).
Royal North Shore Hospital
Other
Phase I Feasibility Study of Prostate Cancer Radiotherapy Using Realtime Dynamic Multileaf Collimator Adaptation and Radiofrequency Tracking (Calypso)
Acronym: CALYPSO
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03269422
Genital Diseases, Genital Diseases, Male
Basking Ridge, New Jersey, United States
View Trial DetailsNCT05754658
Breast Cancer, Breast Diseases
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT03606837
Genital Diseases, Genital Diseases, Male
Bordeaux, France
View Trial DetailsNCT06540794
Genital Diseases, Genital Diseases, Male
Istanbul, Turkey (Türkiye)
View Trial Details