Transfemoral TAVR
DeviceOther names: Transcatheter aortic valve replacement
NCT Number: NCT02628899
To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR).
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Sutter Health System, Sacramento, California, United States
Trial Objectives: To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR).
Methodology: This is a multicenter, prospective trial of TAVR in low-risk patients at up to twelve sites in the United States. The trial will have three arms. The first will comprise 200 patients undergoing transfemoral TAVR. The second arm will comprise200 closely matched historical controls who underwent isolated bioprosthetic SAVR.
Historical controls will be selected from among patients at the same site who have undergone isolated bioprosthetic SAVR within the previous 36 months. TAVR patients will then be matched to SAVR patients using STS database variables to perform propensity matching, including (but not limited to) age, gender, race, ethnicity, STS score, and valve prosthesis size. Once the historical matched controls are identified, detailed chart review will abstract in-hospital and 30-day outcomes for the SAVR cohort.
The third arm of the trial will comprise a registry of TAVR in up to 100 low-risk patients with bicuspid aortic valve. The results from the registry arm will be analyzed independently.
Primary Efficacy Endpoint: All-cause mortality at 30 days following transfemoral TAVR vs. bioprosthetic SAVR.
Primary Safety Endpoint: Defined as the composite of major adverse events at 30 days:
a. all-cause mortality c. spontaneous myocardial infarction (MI) d. reintervention: defined as any cardiac surgery or percutaneous reintervention that repairs, alters, or replaces a previously implanted aortic valve e. VARC life-threatening bleeding f. Increase in serum creatinine to ≥300% (>3x increase compared to baseline) OR serum creatinine ≥4.0 mg/dL with an acute increase ≥0.5 mg/dL OR new requirement for dialysis g. coronary artery obstruction requiring percutaneous or surgical intervention h. VARC major vascular complication i. cardiac tamponade j. cardiac perforation k. pericarditis l. mediastinitis m. hemolysis n. infective endocarditis o. moderate or severe aortic insufficiency p. significant aortic stenosis q. permanent pacemaker implantation r. new-onset atrial fibrillation
Secondary Endpoints (TAVR Cohort):
a. aortic valve mean gradient, maximum gradient, and peak velocity b. calculated aortic valve area c. degree of bioprosthetic valve regurgitation 16. Assessment for subclinical leaflet thrombosis with multislice computed tomography, or transesophageal echocardiography if GFR <50 mL/min/m2, at 1 to 2 months.
Number of Trial Sites: 12
Sample Size: 200 consecutive patients and 200 historical controls, and an additional 100 (up to) patients with bicuspid aortic valve
Patient Population: Patients with severe, symptomatic AS who are determined by the Heart Team to be at low surgical risk (STS score ≤3%).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
For the bicuspid cohort only:
Exclusion criteria
Other names: Transcatheter aortic valve replacement
Other names: Surgical Aortic Valve Replacement
Time frame: 30 days following transfemoral TAVR vs. bioprosthetic SAVR
All-cause mortality at 30 days following transfemoral TACR vs. bioprosthetic SAVR
Time frame: 30 days
Composite of major adverse events at 30 days
Time frame: 30 days
Time frame: 30 Days
Time frame: 30 days
Time frame: 30 days
Time frame: 30 days
Time frame: 30 days, 6 months, 12 months, and 2,3,4 and 5 years
composite of:
Time frame: 30 days
Absence of procedural mortality AND Correct positioning of a single prosthetic heart valve into the proper anatomical location AND Intended performance of the prosthetic heart valve (no prosthesis-patient mismatch and mean aortic valve gradient<20 mm Hg or peak velocity<3 m/s, AND no moderate or severe prosthetic valve regurgitation)
Medstar Health Research Institute
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06894550
Altitude, Altitude Sickness
Bern, Canton of Bern, Switzerland
View Trial DetailsNCT06211296
Aortic Stenosis, Aortic Valve Disease
Thousand Oaks, California, United States
View Trial DetailsNCT05035277
Aortic Stenosis, Aortic Valve Disease
Oslo, Norway
View Trial DetailsNCT06372301
Aortic Stenosis, Aortic Valve Disease
Aarhus, Denmark
View Trial Details