Skip to main content
OpenTrials
Completed

NCT Number: NCT03388047

Feasibility of Multi-Spectral Endoscopic Imaging for Detection of Early Neoplasia in Barrett's Oesophagus

Multispectral imaging represents an exciting new field of investigation in endoscopic research. Multispectral imaging uses a specialised camera to detect multiple colours, allowing us to build a rough spectrum from each point in our image. It is widely reported that these spectra are different for different tissue types, but this is difficult to study ex vivo since de-oxygenation of the blood and decay of the tissue change these spectra considerably.

The investigators have therefore designed this study to asses the different multispectral imaging spectra of Barrett's Oesophagus, which we believe might be utilised as a method to detect dysplasia in the future.

Completed

Looking for future studies?

Notify Me

Key information

About this study

The investigators have developed a custom multispectral endoscopes based around a CE marked device, the PolyScope disposable endoscope (PolyDiagnost). This is a combined sterile catheter and fibre optic device designed to optimize light delivery to the anatomy and to acquire and transmit endoscopic images back to a camera. This CE marked system can be used to endoscope luminal organs such as the oesophagus, but also biliary tract, the bladder and the oro-pharynx.

The PolyScope can be inserted thought the accessory channel of commercial endoscopes. The design of the fibre optic device is durable and re-useable; it is inserted within the disposable sterile catheter channel, which is able to flex and bend to orient the device to the region of interest for imaging. The fibre optic device never comes into contact with the patient. The sterile catheter, which shields the fibre optic device, is disposed following a procedure.

The use of the PolyScope provides the advantage of building on a known system. The commercial PolyScope probe is coupled outside of the patient to a custom multispectral detection and illumination system. No modified part of the device comes into contact with the patient.

The patients recruited to this study will have a clinical indication to an endoscopic examination for Barrett's oesophagus or early oesophageal adenocarcinoma. There will not be extra procedures involved. The experimental part of the procedure, using Polyscope multispectral endoscope will prolong the procedure in most cases by approximately 5-10 minutes

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or female subjects over 18 years
  • Previous diagnosis of Barrett's oesophagus, with an endoscopic length of at least 2 cm
  • Previous diagnosis of oesophageal glandular dysplasia or early oesophageal adenocarcinoma for consideration of endoscopic therapy

Exclusion criteria

  • History of oesophageal stricture precluding passage of the endoscope,
  • Pregnancy, or planned pregnancy during the course of the study,
  • Currently breastfeeding
  • Any history of esophageal varices, liver impairment of moderate or worse severity (Child's- Pugh class B & C) or evidence of varices on initial treatment endoscopy,
  • Any history of oesophageal surgery, except for uncomplicated fundoplication, and,
  • History of coagulopathy, with INR>1.3 and/or platelet count of <75,000.
  • On clopidogrel, and/or warfarin for high risk condition and unable to withhold temporarily the medication.

Treatment and study plan

Endoscopy with Polyscope (Polydiagnost TM) coupled with Multi-Spectral Imaging light-source

Device

During surveillance endoscopy procedure, the endoscopist will insert the multispectral endoscopy probe through the working channel and use this to inspect the Barrett's oesophagus segment and any visible lesions

Primary outcomes

  1. Level of confidence in delineating the area of interest by multispectral imaging

    Time frame: 1 year

    Level of confidence in delineating the area of interest by the multispectral endoscope in terms of image quality and visibility of area of interest assessed by endoscopist using a 1 to 10 Visual Analogue Score (VAS). We will consider the following ranges 0-3 poor; 4-5 fair; 6-8 good, 9-10 excellent

Secondary outcomes

  1. Imaging spectra by multispectral endoscopy in neoplastic vs. non-neoplastic Barrett's

    Time frame: 1 year

    Number and type of image spectra corresponding to neoplastic and non-neoplastic area of Barrett's Oesophagus

  2. Patient comfort

    Time frame: 1 year

    Patient comfort score measured by assisting nurse according to standard scoring scale (1 to 5)

  3. Time

    Time frame: 1 year

    Time to perform multispectral imaging in minutes

  4. Correlation with molecular biomarkers

    Time frame: 1 year

    Comparison of the biomarker features of biopsies directed by multispectral imaging (both neoplastic and non-neoplastic) using a molecular panel assessing aneuploidy, p53 and cyclin A.

Sponsors and collaborators

Lead sponsor

University of Cambridge

Other

Registry information

Official study title

Prospective Pilot Cohort Study to Assess Feasibility of Multi-Spectral Endoscopic Imaging for Detection of Early Neoplasia in Barrett's Oesophagus

Acronym: MuSE

Important dates

Study start
2018
Primary completion
2020
Study completion
2020
First posted
Jan 2, 2018
Registry last updated
Apr 28, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.