Background:
Lung problems develop in up to 20% of people after they have surgery. While under general anesthesia, people breathe slower and draw in less air. They may have difficulty returning to normal deep breathing as they recover. Some may develop life-threatening complications. An approved device called an incentive spirometer is used to help measure and improve a person's breathing after surgery. Researchers want to find out if a motion sensor placed on the chest can also measure the volume of air a person inhales as they breathe.
Objective:
To determine if a motion sensor on the chest can measure the volume of air a person breathes.
Eligibility:
Healthy adults aged 18 years and older.
Design:
* Participants will have one clinic visit. The visit will last 10 to 30 minutes. * They will fill out a form with their age, sex, height, and weight. * A small, plastic motion sensor will be taped to their chest on one or both sides. * Participants will breathe through a tube attached to an incentive spirometer. They will take 18 breaths of different volumes, both deep and shallow. * Researchers will use the data collected from the motion sensors to measure how the chest moves at different levels of breathing. The motion sensor data will be used to create a software program that converts chest wall motion to the volume of air inhaled for a given breath in real time.
Looking for future studies?
Notify Me18 year–100 year
All sexes
Interventional
Not applicable
Bethesda, Maryland, 20892, United States
Study Description:
This protocol is a basic physiologic proof-of-concept study enrolling normal volunteers to determine the feasibility of measuring volume of inspiration from chest wall motion measured via non-invasive thoracic motion sensors. The motion sensors are not medical devices because they are not intended to diagnose a disease or condition or to cure, mitigate, treat or prevent disease. Since motion sensors are not being evaluated for diagnostic purposes or being studied themselves within the context of this protocol and are only intended to collect physiological data, they are not to be considered investigational. The data collected in this feasibility study will not contain any personally identifiable information (PII). In this study, healthy participants will complete a total of approximately 18 measured breaths through a traditional incentive spirometer while wearing small, non-invasive motion sensors on their thorax at approximately the level of the 9th and 10th ribs unilaterally or bilaterally. The incentive spirometer is an FDA approved medical device. This study does not aim to study the safety or effectiveness of this device but rather utilize the device as a tool to measure volume of inspiration. The waveform data collected from the devices with each breath will then be analyzed with the intention to develop an algorithm that could convert chest wall motion to a discrete volume of inspiration in real time. Total enrollment time will be about 10-30 minutes per participant.
Objectives:
Primary: To collect chest wall motion data corresponding to various volumes of inspiration from a non-invasive wearable device.
Secondary: To develop an algorithm which can convert chest wall motion to volume of inspiration and assess the algorithm using cross-validation strategy.
Endpoints:
Primary: A database of motion waveforms corresponding to each measured volume of inspiration via traditional incentive spirometer.
Secondary: A cross-validated algorithm that converts chest wall motion to volume of inspiration.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
In order to be eligible to participate in this proof-of-concept study, an individual must meet all the following criteria:
Exclusion criteria
An individual who meets any of the following criteria will be excluded from participation in this study:
The motion sensor is the 10-axis Bluetooth Gyro Inclinometer by Wit Motion and is marketed for rehabilitation exercises, workplace injury prevention, patient care, and healthy short-range wireless motion measurements.
A device that measures the volume of the air inhaled into the lungs during inspiration.
Time frame: 15-20 minutes from start of the study
Number of participants with collectable waveform data, which corresponds to each breathing exercise from the wearable motion sensor and uploaded to a secured database.
Time frame: Within a month of study completion
Participants with waveform data that support the development and and validation of an algorithm that converts chest-wall motion waveforms into estimated volumes of inspiration. For each participant, motion waveforms is annotated with the corresponding measured inspiratory volumes.
National Institutes of Health Clinical Center (CC)
Nih
Feasibility Of Measuring Volume of Inspiration Via Non-Invasive Motion Sensors
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04677309
Lung Cancer, Lung Diseases
Valencia, Spain
View Trial DetailsNCT07000760
Postoperative Pulmonary Complications (PPCs)
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT07211074
Lung Ultrasound, Postoperative Atelectasis
Moscow, Russia
View Trial DetailsNCT07186920
Lung Diseases, Lung Ultrasonography Score
Pátrai, Greece
View Trial Details