Feasibility of a Minimally Invasive Thoracoscopic Ultrasound for Localization of Pulmonary Nodules

The ex-vivo lung will be evaluated by XLTF-UC180 for localization of the tumor. The ultrasound probe will be put on the lung surface in several different directions to obtain the cross section with maximum diameter. The ultrasound image with size measurement of the tumor will be recorded using an ultrasound scanner (EU-Y0008, OLYMPUS MEDICALSYSTEMS CORP., Tokyo, Japan). Next, the bronchial stump of the specimen will be opened and a small sized endotracheal tube will be inserted to inflate and deflate the lung. After inflation of the lung, the tumor will be evaluated by XLTF-UC180 to see the difference in ultrasound images between deflated and inflated lung. After ultrasound evaluation, the specimen will be delivered directly to the pathology laboratory and the actual tumor size and histological diagnosis will be determined. In addition, we will evaluate the differences between US image and pathological morphology using HE slides of lung tumor. We will work together with the surgical team to confirm sign off of specimens.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

University Health Network

Toronto, Ontario, M5G 2C4, Canada

About this study

This is a single center clinical trial. Forty patients (sufficient for an initial evaluation) scheduled for a lobectomy or an anatomical segmental resection for malignant lung tumors will be enrolled in the study. After lung resection, the lung will be placed on a surgical table in a similar position to the in-vivo situation in the Image Guided Therapeutic operating room (GTx-OR) within Toronto General Hospital. The lung will be evaluated by XLTF-UC180 for localization of the tumor. The ultrasound probe will be put on the lung surface in several different directions to obtain the cross section with maximum diameter. The ultrasound image with size measurement of the tumor will be recorded using an ultrasound scanner (EU-Y0008, OLYMPUS MEDICALSYSTEMS CORP., Tokyo, Japan). Next, the bronchial stump of the specimen will be opened and a small sized endotracheal tube will be inserted to inflate and deflate the lung. After inflation of the lung, the tumor will be evaluated by XLTF-UC180 to see the difference in ultrasound images between deflated and inflated lung. After ultrasound evaluation, the specimen will be delivered directory to the pathology laboratory and the actual tumor size and histological diagnosis will be determined. In addition, we will evaluate the differences between US image and pathological morphology using Hemotoxylin and Eosin (HE) slides of lung tumor. We will work together with the surgical team to confirm sign off of specimens.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Any patients scheduled for lobectomy of anatomical segmental resection for malignant lung tumors.
  • 18 Years of age and older

Exclusion criteria

  • Any patients with inability to give informed consent

Treatment and study plan

Thoracoscopic Ultrasound

Other

We will evaluate the resected specimen using the XLTF-UC180 in the operating room (OR) to determine the localization rate of the targets. Ultrasound measurement and images will be compared to the actual size of the tumor and pathological morphology using HE slides of lung tumor to determine the correlation between those variables. The tumor depth from the lung surface will be also collected to clarify the maximum depth to which the ultrasound can visualize.

Primary outcomes

  1. Comparison of XLTF-UC180 Nodule Measurement with pathological morphology

    Time frame: 2 Years

    The primary objective of this study is to demonstrate the feasibility of thoracoscopic ultrasound for localization of pulmonary nodules in ex-vivo human lungs. We will evaluate the resected specimen using the XLTF-UC180 in the GTx-OR to determine the localization rate of the targets. Ultrasound measurement and images will be compared to the actual size of the tumor and pathological morphology using HE slides of lung tumor to determine the correlation between those variables. The tumor depth from the lung surface will be also collected to clarify the maximum depth to which the ultrasound can visualize

Sponsors and collaborators

Lead sponsor

University Health Network, Toronto

Other

Registry information

Official study title

Feasibility of a Minimally Invasive Thoracoscopic Ultrasound for Localization of Pulmonary Nodules Using Resected Human Lungs

Important dates

Study start
2015
Primary completion
2015
Study completion
2015
First posted
Jan 27, 2016
Registry last updated
Feb 26, 2018