Cardio Flow FreedomFlow™ Orbital Atherectomy System treatment
DeviceOcclusive lesions will be treated using atherectomy with or without adjunctive low pressure balloon angioplasty.
Other names: Orbital Atherectomy Treatment
NCT Number: NCT03365154
This trial is a First in Human early feasibility study of a novel atherectomy device to treat peripheral artery disease. The trial is a prospective, single arm design that will enroll 10 patients at 1 - 2 sites. Patients will be followed at 30 days and 6 months to evaluate vessel patency following treatment. Safety will be assessed by monitoring adverse events throughout the study. Safety and Efficacy will be evaluated by comparing study results to established performance criteria,
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Cardiovascular Research of North Florida, LLC, Gainesville, Florida, United States
Feasibility Clinical Trial of the Cardio Flow FreedomFlow™ Orbital Atherectomy System to Treat Peripheral Artery Disease (FAST Trial) is a prospective non-randomized single arm study that will enroll up to 10 patients at 1 - 2 sites. The study will evaluate the safety and effectiveness of the Cardio Flow atherectomy device for plaque removal in de novo target lesions in the peripheral vasculature of the lower extremities. The primary safety endpoint is defined as freedom from a composite of new onset major adverse events through the 30-day follow-up as adjudicated by an independent Clinical Events physician. The primary effectiveness endpoint is defined as the ability of the Cardio Flow Device to achieve a residual diameter stenosis ≤ 50% without adjunctive therapy, determined by Angiographic core lab evaluation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Occlusive lesions will be treated using atherectomy with or without adjunctive low pressure balloon angioplasty.
Other names: Orbital Atherectomy Treatment
Low pressure balloon angioplasty may be used following atherectomy
Time frame: At time of procedure
Achievement of ≤ 50% residual stenosis without adjunctive therapy as assessed angiographically on a per lesion basis
Time frame: 30 days
Major adverse events include the following:
Time frame: Through six months
All device and procedure related Serious Adverse Events at 30 days and 6 months
Time frame: At time of procedure
Ability to achieve <50% residual diameter stenosis with or without adjunctive low-pressure balloon therapy on a per-lesion basis. Operator can follow atherectomy treatment with adjunctive balloon therapy.
Cardio Flow, Inc.
Industry
Feasibility Clinical Trial of the Cardio Flow FreedomFlow Orbital Atherectomy System to Treat Peripheral Artery Disease
Acronym: FAST
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05858905
Arterial Occlusive Diseases, Arteriosclerosis
Palo Alto, California, United States
View Trial DetailsNCT05009862
Arterial Occlusive Diseases, Arteriosclerosis
Nashville, Tennessee, United States
View Trial DetailsNCT04130737
Arterial Occlusive Diseases, Arteriosclerosis
Mesa, Arizona, United States
View Trial DetailsNCT04283565
Arterial Occlusive Diseases, Arteriosclerosis
Saint-Etienne, France
View Trial Details