Instituto do Coracao (Heart Institute), Faculdade de Medicina, Hospital das Clinicas, Universidade de Sao Paulo
São Paulo, 05403-900, Brazil
NCT Number: NCT05966857
This study aims to develop a digitally assisted telemonitoring platform using the Samsung TM Galaxy Watch5 smartwatch, validating the applicability of the solution in patients with POAF (Postoperative Atrial Fibrillation), along with the accuracy of the smartwatch in detecting vital signs through optical sensors and possibly identifying irregularities in heart rhythm. The validation of its applicability will be carried out through a clinical trial. This is a randomized observational pilot study resulting from the partnership established in the base year of 2022 between InCor and Samsung.
The sample consisted of 108 outpatient patients with cardiac diseases who underwent cardiac surgery and were selected during the preoperative consultation. Subsequently, the patients were randomized (1:1) into the intervention group (teleassisted group) or the control group (standard institution follow-up).
The sample size was proposed by the contracting party as this is a pilot study to assess whether the implementation of a technological solution assists in monitoring and predicting the risk of surgical patients in the postoperative phase, as well as the accuracy of the Samsung TM Galaxy Watch5 smartwatch in a sample with POAF.
Looking for future studies?
Notify Me22 year and older
All sexes
Interventional
Not applicable
São Paulo, 05403-900, Brazil
This interventional study was conducted exclusively at the Heart Institute of the Clinics Hospital of the Medical School of the University of São Paulo (InCor - HCFMUSP). It was a single-center study divided into six phases.
The first phase involved outpatient preoperative care, where patients underwent a comprehensive anamnesis during the preoperative consultation and were informed about the study. In the second phase, patients were hospitalized and provided with the Informed Consent Form (ICF) if they met the inclusion criteria. Demographic data were collected during this phase.
During the surgical phase (third phase), intraoperative data were collected after cardiac surgery. The fourth phase focused on postoperative care, where patients were evaluated, and health measures such as blood pressure (BP), heart rate (HR), electrocardiogram (ECG), and peripheral oxygen saturation (SpO2) were collected using the SAMSUNGTM Galaxy Watch5 smartwatch and reference devices.
After discharge, the fifth phase involved a 30-day telemonitoring period, where patients were remotely monitored using the smartwatch. Health data, including BP, HR, ECG, and SpO2, were collected three times a day during this phase. The medical team provided clinical interventions when alerts were received via the "FAPO SI³" platform.
In the final phase, patients returned for an outpatient visit at InCor, where health measures were collected again using the smartwatch and reference devices. Additionally, a World Health Organization Quality of Life (WHOQOL) questionnaire was administered to assess patients' quality of life. ECG reports issued by the smartwatch were also reviewed.
The control group consisted of patients with heart disease who underwent surgical procedures and received standard outpatient and post-surgical follow-up according to institutional routines and protocols.
Overall, the study aimed to develop and validate an assisted digital telemonitoring platform for patients with postoperative atrial fibrillation (POAF). The telemonitored group used the SAMSUNGTM Galaxy Watch5 smartwatch for remote monitoring, while the control group followed standard care protocols.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The SAMSUNGTM Galaxy Watch5 Smartwatch, is a new generation of smartwatches, features an innovative 3-in-1 BioActive sensor, which uses a chip to capture optical and read cardiac electrical current, allowing to carry out high-quality real-time single-lead electrocardiogram. Despite the more compact design, there is no decrease in accuracy. These signals are then processed by the device's algorithms and can be sent to a trained professional for evaluation immediately after the measurement, facilitating the monitoring and diagnosis of arrhythmias.
Time frame: 30-day
Frequency (n, %)
Time frame: 30-day
Frequency (n, %)
Time frame: 30-day
Frequency (n, %)
Time frame: 30-day
Frequency (n, %)
Time frame: 30-day
Frequency (n, %)
Time frame: 30-day
Frequency (n, %)
University of Sao Paulo
Other
Acronym: FAPO-X
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03491163
Heart; Surgery, Heart, Functional Disturbance as Result
Kaunas, Kaunas County, Lithuania
View Trial DetailsNCT04094168
Heart; Surgery, Heart, Functional Disturbance as Result
Majadahonda, Madrid, Spain
View Trial DetailsNCT06475703
Heart; Surgery, Heart, Functional Disturbance as Result, Infections
London, United Kingdom
View Trial DetailsNCT03429335
Cardiovascular Abnormalities, Cardiovascular Diseases
Edmonton, Alberta, Canada
View Trial Details