PET Center
New Haven, Connecticut, 06519, United States
NCT Number: NCT02727972
This research study is designed to look at the involvement of the glutamate system in depression. Each subject will undergo a screening appointment to determine study eligibility. Thereafter, the study will take 2 or 3 visits depending on schedule availability and will consist of one MRI scan, and PET scan. Subjects will also participate in cognitive testing. Depending on camera time, staff availability and subject schedule, total study participation may last 1-2 months.
Looking for future studies?
Notify Me18 year–70 year
All sexes
Interventional
Not applicable
New Haven, Connecticut, 06519, United States
With the recent advancements in positron emission tomography (PET) and radioligand development, the investigators are now able to image and quantify the metabotropic glutamatergic system (mGluR5) in vivo in human subjects. The study proposes a novel investigation of mGluR5 in depression to obtain critical data to advance understanding of the etiology of depression and its associated symptoms of cognitive dysfunction.
Aim 1: To determine mGluR5 availability in individuals with mood disorders compared to healthy controls as measured with PET brain imaging.
Hypothesis 1: The study hypothesizes a decrease in mGluR5 availability in individuals with mood disorders in regions responsible for emotional and cognitive processes, including the amygdala, hippocampus, thalamus, anterior cingulate, and frontal cortices.
Aim 2: To determine if glutamate cycling in individuals with mood disorders is altered as compared to healthy controls as measured with [1H]MRS and [13C]MRS.
Hypothesis 2: The study hypothesizes an increase in glutamate number in individuals with mood disorders as compared to controls.
Aim 3: To determine if the PET alterations in the glutamatergic system of depressed individuals are associated with cognitive deficits observed in depression, including concentration, attention, memory, distractibility, and startle.
Hypothesis 3: The study hypothesizes a positive relationship between mGluR5 availability and cognitive functioning, such that individuals with higher receptor availability will perform better on tests of concentration, attention, memory, distractibility, and startle than individuals with lower receptor availability.
Aim 4: To determine mGluR5 availability in individuals with anxiety and schizophrenia compared to healthy controls as measured with PET brain imaging.
Hypothesis 4: Anxiety disorders such as obsessive compulsive disorder, and delusional disorders such as schizophrenia are frequently comorbid with mood disorders, and the glutamatergic system has been observed to be compromised in these individuals as well. This study will examine if there are regional differences in mGluR5 availability between individuals with depression, bipolar disorder, obsessive compulsive disorder, and schizophrenia.
Aim 5: To examine whether changes in mGluR5 availability are dependent on state, or whether the lower availability is due to trait.
Hypothesis 5: Due to changes in endogenous GLU shown with MRS studies, this study hypothesizes normalization (or increase) in mGluR5 availability in euthymia as compared to depressed state.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
General inclusion criteria:
Inclusion criteria
for acute depressed subjects:
Inclusion criteria
for PTSD subjects:
Inclusion criteria
for healthy controls:
Exclusion criteria
Verbal assessments as well as computer testing.
Anatomical MRIs will be performed on a Siemens 3T Trio at Yale. MR acquisition will be a Sag 3D magnetization-prepared rapid gradient-echo (MPRAGE) sequence with 3.34 ms echo time, 2,500 ms repetition time, 1,000 ms inversion time, 7 degree flip angle, and 180 Hz/pixel bandwidth. The image dimensions will be 256 x 256 x 176 and pixel size 0.98 x 0.98 x 1.0 mm. Resting state MRIs will also be obtained as follows: We will be doing 2 six minute scans with subjects in the scanner, eyes open, fixating a cross. TR = 3 secs 45 slices x 3 mm slice thickness = 13.5 cm. In plane resolution = 3 x 3 mm, slice acquisition order = ascending.
Other names: Magnetic Resonance Imaging
High Resolution Research Tomograph (HRRT), the highest resolution human brain scanner available, or HR+ will be used to image subjects. Vital signs (blood pressure, pulse, respiration) will be obtained before and after radiotracer administration. An antecubital venous catheter will be used for IV administration of the radiotracer and for venous blood sampling. A radial artery catheter will be inserted by an experienced physician before the PET scan. At the beginning of each scan, the subject's head will be immobilized and a 6 minute transmission scan using an orbiting 137Cs (HRRT) or 68GE (HR+) point-source is obtained and used for attenuation correction. PET scans will be acquired using bolus or bolus plus constant infusion administration of FPEB or ABP688.
Other names: Positron Emission Tomography
Time frame: Through study completion date, an average of 4 years.
Yale University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02256566
Anxiety Disorders, Behavior
New York, United States
View Trial DetailsNCT03898297
Behavior, Behavioral Symptoms
New Haven, Connecticut, United States
View Trial DetailsNCT02453438
Behavior, Behavioral Symptoms
Boston, Massachusetts, United States
View Trial DetailsNCT06282146
Anxiety Disorders, Behavior
Boston, Massachusetts, United States
View Trial Details