Evaluation Study of HCV RDTs in Fresh Samples

This study evaluates the sensitivity and specificity performance of three Hepatitis C Virus (HCV) rapid diagnostic tests (RDTs) in freshly collected fingerstick whole blood, as well as serum and plasma (Premier Medical Corporation First Response HCV RDT; Beijing Wantai HCV RDT; AccessBio Care Start HCV under development). Performance is compared to the SD Bioline HCV RDT, as well as a composite reference standard, consisting of two enzyme Immunoassay and a line immunoassay.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Sihanouk Hospital Centre of Hope, Phnom Penh, Cambodia

Loading trial locations.

About this study

Hepatitis C virus (HCV) infection is a major public health burden, with an estimated 71 million patients being infected globally. If undiagnosed, HCV infection can lead to severe liver damage, including hepatocellular carcinoma (HCC). The World Health Organization (WHO) recently set a target to eliminate HCV by 2030. The first critical step in reaching this target is to accurately identify people infected with HCV. Globally, significant gaps remain in diagnosis of HCV, with four out of five people infected still unaware of their status, largely due to lack of access to testing services.

In resource-limited settings (RLS), laboratory-based testing remains a mainstay for HCV screening and confirmatory testing. Such laboratory-based assays rely on transportation of temperature-sensitive samples from clinic sites to centralized laboratories, high-tech equipment and highly skilled laboratory technicians, limiting the scope of access to testing and resulting in long turn-around times for results. In recent years, new technologies have been developed to decentralize HCV screening and confirmatory testing using point-of-care (POC) assays to overcome these barriers and improve patient outcomes.

Rapid diagnostic tests (RDT) for screening for HCV are affordable, accurate, easy to use by healthcare workers, and robust in field settings. Although a number of HCV RDTs are on the market, currently only two have received WHO pre-qualification (PQ) status, demonstrating their accuracy and reliability for use in the field in RLS. Data on a number of other RDTs indicate their suitability for use. More data is needed, however, in field settings for these HCV RDTs, to demonstrate their accuracy and quality in end-user studies and to provide evidence for WHO PQ approval.

Based on the results of a recent FIND laboratory evaluation assessing the performance of 13 HCV RDTs using archived plasma samples, we have selected three candidate HCV RDTs ("study RDTs") for further evaluation in field settings (e.g. primary healthcare facilities). The performance of these RDTs measured in frozen plasma specimens indicated that they have a high potential to meet WHO PQ performance criteria in freshly collected samples. In addition, the manufacturers each demonstrate evidence of engagement to pursue both CE-mark status and the WHO PQ process, showing commitment to delivering quality-assured tests to the market.

The data generated during this study will be used to inform national and international stakeholders on HCV RDT performance in field settings and shared with manufacturers to support the evidence package for WHO PQ and/or CE-marking.

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • ≥ 18 years of age
  • Known or unknown HCV serology
  • No history of past or present HCV treatment
  • Willing to undergo the information and consenting procedure and subsequently have enough time to participate in the study
  • Willing to provide 13 ml venepuncture blood sample and a minimum of four whole blood fingerstick samples
  • Willing to perform an HIV test
  • Individuals can already be registered at the local site or register for the first time when enrolling in the study

Exclusion criteria

  • Participants not able to consent themselves (incapable)

Treatment and study plan

Test for HCV antibodies with an RDT

Diagnostic Test

Fingerstick whole blood, plasma and serum of each participant is tested with three investigational HCV RDTs and one reference HCV RDT. Plasma is also used for testing with the composite reference standard, HCV viral load and genotyping. All participants are also tested for HIV with an HIV RDT.

Primary outcomes

  1. Sensitivity and specificity of HCV RDTs compared to a composite reference standard

    Time frame: through study completion, on average 1 year

    1.1 Point estimates of sensitivity, specificity, positive and negative predicative values (with 95% confidence intervals) and Cohen's Kappa Coefficient (κ) of inter-rater agreement for each RDT, using a combination of two EIAs (Enzyme Immunoassay) and an LIA (Line immunoassay) as a composite reference standard for the detection of anti-HCV antibodies in fingerstick whole blood, EDTA plasma and serum.

Secondary outcomes

  1. Sensitivity and specificity of HCV RDTs compared to an HCV RDT pre-qualified by WHO as reference standard

    Time frame: through study completion, on average 1 year

    2.1 Point estimates of sensitivity, specificity, positive and negative predicative values (with 95% confidence intervals) and Cohen's Kappa Coefficient (κ) of inter-rater agreement for each RDT, using the WHO-PQ RDT as reference standard for the detection of anti-HCV antibodies in fingerstick whole blood, EDTA plasma and serum

  2. Operational characteristics

    Time frame: through study completion, on average 1 year

    2.2 Operational characteristics and usability of study RDTs:

    • Rate of invalid test results /errors: Percentage of invalid test results/errors by RDT, site and error type
  3. Operational characteristics

    Time frame: through study completion, on average 1 year

    Operational characteristics and usability of study RDTs:

    • Technical appraisal rating on kit instructions, labelling and test conduct, on a Likert scale

Sponsors and collaborators

Lead sponsor

Foundation for Innovative New Diagnostics, Switzerland

Other

Collaborators

  • Institute of Tropical Medicine, Belgium

Registry information

Official study title

Prospective Diagnostic Accuracy Study of Rapid Diagnostic Tests (RDTs) Detecting Antibodies Against Hepatitis C Virus (HCV) in Freshly Collected Whole Blood, Plasma and Serum

Important dates

Study start
2019
Primary completion
2019
Study completion
2020
First posted
Oct 25, 2019
Registry last updated
Jul 7, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.