Hopital de la Croix Rousse
Lyon, 69004, France
NCT Number: NCT03469193
Unicompartmental knee arthroplasty by unicompartmental prosthesis (PUC) is a treatment for isolated internal femoro-tibial osteoarthritis. This intervention is justified in cases of significant discomfort, failure of medical treatment and the absence of osteoarthritis in femoro tibial external and patellofemoral femoro compartments. It aims to replace the native internal femoral tibial articulation by a joint between two implants, without intervening on the other compartments. The functional results of PUC are superior and faster than those obtained with total knee arthroplasty (TKA). Its indications and its realization are on the other hand very demanding to allow an optimal functional result.
Robotic-assisted surgery provides an excellent level of precision, which could allow better positioning of implants, compared to the use of a mechanical ancillary, according to the first published studies. The functional results and survival of these implants could also be improved.
The internal PUC with mechanical ancillary is carried out for many years in the orthopedic surgery department of Croix Rousse. For 3 years this surgery is sometimes performed with robotic assistance.
The investigators would like to prospectively evaluate the clinical and radiological impact of robotic-assisted surgery when performing a Journey unicompartmental prosthesis (Smith & Nephew).
The assessment of alignment during walking seems to be a paramount parameter in the results of the PUC and has not so far been evaluated in this type of robotic-assisted surgery.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Lyon, 69004, France
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The control group consists of patients operated with a mechanical ancillary (reference surgery in our department). In this technique, bone sections are made with a standardized ancillary (manually adjusted bone cutting guides), according to preoperative radiological planning. The positioning of the implants is done manually and controlled by the placement of test implants.
Patients are operated by robotics (surgery that we want to develop systematically in our service). 3D modeling of the knee allows the operator to perform a dynamic planning taking into account the reducibility of the deformation and the model of the implant. The operator can position the implants in three dimensions of the space without difficulty. This makes it possible to visualize, before the bone resections, the angular correction obtained between 0 and 130° flexion and alignment of the prosthesis by visualizing the contact points between the two implants. Bone resections will be performed using a guided retro bone drill. The system retracts more or less the cutter according to the bone thickness to be removed. This technique requires the insertion of two threaded plugs in the tibia and two in the femur to position the sensors that will allow the acquisition of anatomical landmarks of the lower limb and then 3D modeling
Time frame: At 6 month postsurgery
This criterion will be measured using a KneeKG system for dynamic analysis of knee movements.
This system is non-invasive, non-radiating, non-painful. It is a dynamic tibiofemoral tracing device by infrared camera validated. The KneeKG system will be used according to its instructions for use.
Time frame: At 6 month and 24 month postsurgery
Measurements of HKA, frontal alignment of tibial and femoral implants, sagittal alignment of the femoral implant, tibial implant slope and the presence of peri-prosthetic edgings will be performed on a Standard radiography of the knee operated from the front, in profile and on a standing pangonometry
Time frame: At 6 month and 24 month postsurgery
This is the international benchmark for clinical and functional evaluation in knee surgery. The 2011 version provides a more accurate, complete and comprehensive vision than the previous version.
Time frame: At 6 month and 24 month postsurgery
The Forgotten score helps to analyze the patient's attention to the fact that his articulation has been replaced.
Hospices Civils de Lyon
Other
Evaluation Protocol of the Installation of Knee Unicompartmental Prosthesis (Journey (Smith & Nephew)) With Mechanical Ancillary Versus Robotic Assisted (Navio System). Prospective, Monocentric, Randomized, Open Label Study.
Acronym: PUC NAVIO
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06693648
Arthritis, Joint Diseases
Thousand Oaks, California, United States
View Trial DetailsNCT07471204
Arthritis, Healthy Participants
Istanbul, Büyükçekmece, Turkey (Türkiye)
View Trial DetailsNCT06734052
Arthritis, Behavior
Milwaukee, Wisconsin, United States
View Trial DetailsNCT06989645
Arthritis, Joint Diseases
Uppsala, Sweden
View Trial Details