Department of Removable Prosthodontics, University of Damascus Dental School
Damascus, Rif-dimashq Governorate, DM20AM18, Syria
NCT Number: NCT02203279
Purpose: The purpose of this study is to evaluate three hard relining materials after 3 and 6 months of use with mandibular complete dentures. The effect of hard relining materials on supporting tissues and patients' satisfaction will also be assessed.
Materials and Methods: 36 complete edentulous patients who already have maxillary dentures and complaining of instable mandibular dentures will be invited to participate in this study. Mandibular dentures will be relined randomly by one of three relining materials: two chairside relining materials (Tokuyama Rebase II Fast, Tokuyama Dental Co, Japan), and (Flexacryl Hard, Lang Co, USA) and one heat cured acrylic resin (Vertex, Dental technology Co, Holland).
The color stability of relining material, peeling, and the effect on supporting tissue will be assessed by two separate prosthodontists after 3 and 6 months of follow up. In addition, patients will be asked to grade there overall satisfaction on a Visual Analogue Scale (VAS) ranging from 0 to 100.
Looking for future studies?
Notify Me47 year–78 year
Male
Interventional
Not applicable
Damascus, Rif-dimashq Governorate, DM20AM18, Syria
Relining denture is a process of resurfacing the tissue side of a denture to make it fit more accurately Direct relining of removable dentures with hard chair-side reline materials is suitable for improving the fit of the denture bases to the supporting tissues. Chairside reline materials are more convenient than those processed in a laboratory because the direct method is faster and does not cause clinically significant dimensional changes of the reline resin. However, when autopolymerized reline resins are used with a direct method, several problems can occur as burning sensation caused by monomers, an exothermic heat reaction and an unpleasant odor.
There are three types of hard relining chair-side materials: Dual-polymerized Visible light-polymerized as Triad DuaLine, Light Liner (Hard), Astron LC (Hard).Visible light-polymerized as Lightdon-U, Triad Hi-Flow Reline Material, Triad VLC Reline Material. Finally, autopolymerized as New Truline, Tokuyama Rebase II (Fast) , GC Reline. Other concerns related to direct reline materials include patient tolerance (taste, temperature, odor), color stability, durability and ease of handling and polishing.
Few studies evaluated the effect of disinfection solutions on relining materials properties as roughness and hardness. In one study, disinfectant solutions caused a decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Depending on the examined relining materials, some materials have increased and the others have decreased surface roughness after immersion in disinfecting solutions or microwave disinfection.
All previous laboratory studies concentrated on the effects of disinfection on relining materials properties as roughness, hardness, color change. However, the clinical studies did not compare chemically cured and heat cured relining materials and their effects on supporting tissue. The aim of this study is to evaluate the clinical performance of two -chemically cured- and heat cured denture relining material after 3 and 6 months of use. In addition, the effect of hard relining materials on supporting tissues, and patients' satisfaction has not been evaluated yet.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
It is going to be used a direct relining material
This is going to be used as a second direct relining material
This is going to be used as an indirect relining material
Time frame: This will be measured at three months following relining
According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:
Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.
Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.
Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.
Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.
Time frame: This variable will be assessed at six months following relining
According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:
Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.
Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.
Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.
Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.
Time frame: This will be assessed at three moths following relining
The color stability variable has four degrees on clinical examination:
Time frame: This be assessed at six months following relining
The color stability variable has four degrees on clinical examination:
no change simple medium large
Time frame: This variable is going to be assessed at three months following relining
This variable is going to be inspected clinically and it has two categories:
Time frame: This variable is going to be assessed at six months following relining
This variable is going to be inspected clinically and it has two categories:
Time frame: This is going to be measured at three months following relining
Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.
Time frame: This is going to be measured at six months following relining
Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.
Damascus University
Other
Evaluation of Three Hard Relining Materials in Complete Dentures: An In-vivo Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.