Total face mask (interface for NPPV)
DeviceNPPV is applied by this mask, as long as NPPV is received.
Other names: cephalic mask
NCT Number: NCT00686257
The purpose of this study is to compare the Total Face Mask™ (Respironics, Inc., Pittsburgh, PA) (covering whole face) and the standard oronasal facemask (covering nose and mouth) for the emergency treatment of patients with acute respiratory failure with the machine blowing air into the mask placed on the face (noninvasive positive pressure ventilation) (NPPV).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Tufts Medical Center, Boston, Massachusetts, United States
Despite its demonstrated efficacy in treating selected patients with acute respiratory failure, the application of NPPV is still plagued by a substantial failure rate, ranging from below 10% to above 40%. Mask intolerance ranks as one of the most common causes of failure. This is related to ill-fitting masks, mask discomfort (despite a properly fitted mask), excessively tightened straps, excessive air leaks around the mask or through the mouth, and claustrophobia.
The most commonly used masks in the acute care setting are either oronasal masks that cover the nose and mouth, or nasal masks that cover the nose alone. Both mask types usually consist of clear plastic dome-shaped mask with a soft silicon gasket to create an air seal with the skin. While this approach is usually successful, it may lead to patient discomfort and/or an air leak secondary to the difficulty in creating an effective seal over the bridge of the nose and over mobile structures such as the mandible. The Total Face Mask ™ (Respironics, Inc., Pittsburgh, PA) uses a different approach to avoid some of these limitations. Considerably larger than a standard oronasal mask, it covers the entire face and creates an air seal using a silicon gasket around the parameter of the face. In this way, gasket pressure is more evenly distributed, and discomfort over the bridge of the nose or chin is eliminated, and air leaking reduced. In addition, because one mask size fits virtually all patients, the Total Face Mask ™ facilitates the fitting process and permits more rapid initiation of ventilatory assistance. Clinical experience to date suggests that claustrophobia is not a common problem with the Total Face Mask ™ despite its size, and that its contribution to dead space is comparable to that of most oronasal masks.
The following protocol aims to compare use of the Total Face Mask ™ to the Comfort Full oronasal mask (also by Respironics, Inc., Pittsburgh, PA)or RT040 oronasal mask (Fisher&Paykel Inc., Wellington, NZ) in the acute care setting for patients meeting standard indications for NPPV.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
A. Clinical Criteria: Moderate to severe respiratory distress as evidenced by tachypnea, use of accessory muscles for breathing, or abdominal paradox.
B. Blood Gas and Physiologic Criteria: Gas exchange abnormalities including PaCO2>45 with a pH<7.35, or a PaO2/FiO2 ratio<200.
Exclusion criteria
NPPV is applied by this mask, as long as NPPV is received.
Other names: cephalic mask
NPPV is applied by one of these masks (Comfort full or RT040 masks used at Rhode Island Hospital and Tufts Medical Center respectively), as long as NPPV is received.
Other names: Full face mask
Time frame: During the first 3 hours of recruitment
Time frame: at the initiation of NPPV
Time frame: During hospitalization period (after recruitment into the study)
Defined as the inability of the patient to be maintained on NPPV using the assigned mask while there was still an indication for ventilatory support
Time frame: during the first 24 hours of the study
Time frame: during the first 24 hours of the study
Time frame: during hospitalization (after recruitment)
Time frame: during hospitalization (after recruitment)
Time frame: during hospitalization (after recruitment)
Tufts Medical Center
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02939963
Acute Respiratory Insufficiency
Lyon, France
View Trial DetailsNCT04346693
Acute Respiratory Insufficiency, Acute Respiratory Tract Infection
Moscow, Russia
View Trial DetailsNCT03145974
Acute Respiratory Insufficiency, Respiration Disorders
Santiago de Compostela, A Coruña, Spain
View Trial DetailsNCT03358043
Acute Respiratory Insufficiency, Respiration Disorders
Abergavenny, United Kingdom
View Trial Details