"Medical Center Ramus" EOOD
Sofia, 1000, Bulgaria
NCT Number: NCT06477432
The investigation is a single-centre, interventional, prospective, non-randomized, open-label, uncontrolled, single-arm, un-blinded investigation for the evaluation of the safety and performance of the product mesofiller® mesotox in the treatment of wrinkles and imperfections. The clinical investigation is interventional and prospective in agreement with the pre-market regulatory status of the product.
Looking for future studies?
Notify Me20 year–70 year
All sexes
Interventional
Not applicable
Sofia, 1000, Bulgaria
The product mesofiller® mesotox is a dermal filler manufactured by mesoestetic Pharma Group s.l. It was intended to be used as a temporary dermal filler for dermatological treatment for aesthetic purposes. The product provides a temporary filling of dermal tissue to correct small skin defects, such as wrinkles or scars in the upper part of the face, while also providing hydration to the face.
mesofiller® mesotox is a sterile, injectable, gel colourless, transparent, non-pyrogenic, reabsorbable product made out of cross-linked hyaluronic acid of non-animal origin, produced via bacterial fermentation.
This clinical investigation was conducted as an uncontrolled - no comparator medical device or other product was used. The safety and performance of the treatment were evaluated by comparison of the condition with the state of the treated area before initiation of the procedure, conducted by the trained Principal Investigator.
The investigated product mesofiller® mesotox was applied by intradermal or subcutaneous injection by the investigator during Session 1 for all subjects and Session 2 for the subjects, for whom a touch-up was considered beneficial. Both sessions were conducted within 14-day intervals.
The evaluation process during the medical examination was facilitated by photographic evidence taken before and after therapy at predetermined time points for reference.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The investigated product mesofiller® mesotox was applied by intradermal or subcutaneous injection by the investigator during Session 1 for all subjects and Session 2 for the subjects, for whom a touch-up was considered beneficial. Both sessions were conducted within 14-day intervals.
Time frame: Two months after the first treatment (Session 3 (Day 60)).
Time frame: Session 1 (Day 1); Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
The absolute change in Lemperle's Scale from baseline as evaluated by the investigator based on the photographs of the treated area.
The Lemperle's scale is a six-point photographically based classification (0 means no wrinkles, 5 means very deep wrinkles, redundant folds) of mimetic wrinkles and folds that are graded using reference photographs.
Time frame: Session 1 (Day 1); Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180) .
The absolute change in Glogau class from baseline as evaluated by the investigator based on the photographs of the treated area. Glogau photoaging classification includes grades from Grade/Type I (mild) meaning no wrinkles to Grade/Type IV (severe) meaning only wrinkles.
Time frame: Session 1 (Day 1); Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
The absolute change in the Wrinkle Severity Rating Scale from baseline, evaluated by the PI based on photographs of the treated area. The scale ranges from grade 1 to 5, with grade 1 representing the best possible outcome.
Time frame: Session 1 (Day 1); Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
The absolute change in the Wrinkle Severity Rating Scale from baseline, evaluated by the patient. The scale ranges from grade 1 to 5, with grade 1 representing the best possible outcome.
Time frame: Session 1; Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
Improvement in the Global Aesthetic Improvement Scale as evaluated by the PI based on the photographs of the treated area. GAIS ranges from grade 1 to 5, where grade 1 shows exceptional improvement.
Time frame: Session 1; Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
Improvement in the Global Aesthetic Improvement Scale as evaluated by the patient. GAIS ranges from grade 1 to 5, where grade 1 shows exceptional improvement.
Time frame: Session 1; Session 2 (Day 14); Session 3 (Day 60); and Session 4 (Day 180).
The Patient's Questionnaire was utilised. The satisfaction survey grades range from 1 to 3, where grade 1 represents the highest satisfaction level.
Time frame: Session 1 (Day 1); Session 2 (Day 14); and Session 4 (Day 180).
Mesoestetic Pharma Group S.L.
Industry
An Open-label Uncontrolled Single Centre Investigation for the Evaluation of the Safety and Performance Characteristics of the Dermal Filler of Mesoestetic Mesofiller Mesotox for the Correction of Wrinkles and Rehydration of the Face. Clinical Investigation to Assess Safety and Performance of Mesofiller Mesotox.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06997380
Facial Skin Laxity, Facial Wrinkles
Kowale, Poland
View Trial DetailsNCT06604832
Skin Aging, Skin Wrinkling
Pasadena, California, United States
View Trial DetailsNCT06674005
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Connective Tissue Diseases
Naples, Italy
View Trial DetailsNCT06486740
Skin Aging, Skin Wrinkling
Sofia, Bulgaria
View Trial Details