MFM
DeviceImplantation of the MFM
Other names: Multilayer Flow Modulator, Multilayer stent
NCT Number: NCT01756911
Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair.
The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients at high surgical risk presenting with a type II, III thoracoabdominal aneurysm, below the left subclavian and above the iliac bifurcation, according to the Crawford classification.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Hopital Jean Minjoz, Besançon, France
Conventional treatments of thoracoabdominal aneurysm are medical treatments (based on hypertension control) on one hand and surgical treatment on the other hand.
The standard treatment is surgery consisting of an exclusion of the aneurysm with restoration of continuity by means of a prosthesis usually made of Dacron.
Analyses identify risk factors increasing the morbidity and mortality:
Compared to surgery, endovascular stenting reduces:
However, this treatment has a number of limitations
In the current available treatment for this pathology, there are still some disadvantages such as the difficulty of precise positioning of the prosthesis and its branches which must cover the aneurysm tissue without endoleaks. Each lesion having anatomical specificities, the device must be designed for each individual patient, and the operator's technical ability must be extreme. So, the current technique is difficult to reproduce, and any emergency treatment is impossible.
The multilayer flow modulator (non-covered) is the device used in this trial The complications mentioned above are inherent in the concept of covered stent treatment plus endoleaks that continues to fuel the aneurismal sac untreated, thus subject to the persistent risk of rupture. With this technique, the visceral arteries are occluded or have a retrograde flow (which pressurizes the aneurysm again).
The multilayer flow modulator (non-covered) treatment approach avoids the major problems mentioned above:
The space-age 3D geometrical design of a Cardiatis multilayer flow modulator modifies flow within the aorta in a way that reduces pressure within the aneurysm thus collapsing the aneurismal sac while preserving any vital collateral circulation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Implantation of the MFM
Other names: Multilayer Flow Modulator, Multilayer stent
Time frame: 12 months
Time frame: 12 months
Time frame: 12 months
Cardiatis
Industry
Evaluation du Stent Multicouches Dans le Traitement Des anévrismes de l'Aorte Thoraco-abdominale
Acronym: STRATO
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02323581
Acute Aortic Syndrome, Aneurysm
New York, United States
View Trial DetailsNCT03024554
Aneurysm, Aortic Aneurysm
Brussels, Uccle, Belgium
View Trial DetailsNCT03959670
Aneurysm, Aortic Aneurysm
Milan, Italy
View Trial DetailsNCT04190979
Acute Kidney Failure, Acute Kidney Injury
Aachen, Germany
View Trial Details