Skip to main content
OpenTrials
Completed

NCT Number: NCT02917668

Evaluation of the Risk of Hyperoxia-induced Hypercapnia in Obese Cardiac Surgery Patients

This study aims to evaluate the risk of hyperoxia-induced hypercapnia in post-op obese cardiac surgery patients. It will compare two oxygenation modes in terms of their effect on the arterial partial pressure of carbon dioxide (PaCO2) : manual titration of oxygen delivery for a peripheral oxygen saturation (SpO2) target of > or = 95 % versus automatic titration by a closed-loop system for a SpO2 target of 90%. 15 post-op obese cardiac surgery patients will be recruited and each will receive both interventions (cross-over design). The main outcome will be the PaCO2, which will be compared after each study period. The research hypothesis is that the usual SpO2 target of > or = 95 % is associated with a greater PaCO2 compared with a lesser SpO2 target of 90%.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Institut universitaire de cardiologie et de pneumologie de Québec

Québec, G1V4G5, Canada

About this study

This study aims to evaluate the risk of hyperoxia-induced hypercapnia in post-op obese cardiac surgery patients.

The investigators will compare two oxygenation modes in terms of their effect on PaCO2 : a SpO2 target of > or = 95 % achieved with manual titration (usual practice) and a more conservative SpO2 target of 90 % achieved with automatic titration by a closed-loop system (FreeO2).

The choice of a SpO2 target of 90 % is consistent with recent guidelines issued by the British Thoracic Society and the Thoracic Society of Australia and New Zealand, which both recommend a SpO2 target of 88-92 % for morbidly obese patients (BMI > 40 kg/m2).

FreeO2 is a closed-loop oxygen delivery system which adjusts the oxygen flow according to the patient's real-time SpO2 and a target programed by the physician. The system also records data on heart rate, respiratory rate and SpO2. Its safety and efficacy have been tested in healthy subjects as well as in patients suffering from COPD or acute respiratory distress in the emergency room, with promising results.

The research hypothesis is that the usual SpO2 target of > or = 95 % is associated with a greater PaCO2 compared with a lesser SpO2 target of 90%.

30 obese patients will be recruited* at the Institut universitaire de cardiologie et de pneumologie de Québec. A written consent from the patient will be obtained the day before the surgery. The protocol has been submitted to and approved by the establishment's ethics committee.

The study will compare the effect of two different oxygenation modes on the patients' PaCO2 immediately after extubation :

FreeO2 mode : oxygen delivered by nasal cannula or Venturi mask (if flow > 5L/min during > 5 minutes), automatically titrated for a SpO2 of 90 +/- 2 %

Usual mode : oxygen delivered by Venturi mask, manually titrated for a SpO2 superior or equal to 95 % (the local protocol is to deliver a post-extubation FiO2 which is 10 % superior to the pre-extubation FiO2)

Patients meeting all of the eligibility criteria will be randomized in the postoperative period. After extubation, they will receive oxygen for 30 minutes according to FreeO2 mode or the usual mode, depending on randomization. After 30 minutes, a first arterial blood gas will be obtained through their arterial cannula. Next, they will be oxygenated according to the second oxygenation mode for another 30 minutes, after which a second arterial blood gas will be obtained. Each patient will thus act as his own control (cross-over design).

When patients will be oxygenated according to the usual mode, FreeO2 will be in recording mode, but will not be delivering any oxygen.

The study will last 1h for each patient, and will have to begin within 30 minutes after extubation. A member of the research team will be at the patient's bedside for the whole data collecting period.

Complete data collection should be achieved within 12 months.

Demographic data (age, sex, weight, height and BMI) will be collected upon study entering as well as pre-operative room air PCO2 on capillary blood gas, type of surgery (number of bypass grafts, extracorporal circulation time), opiates dosage per-op and post-op, and pre-op left ventricular ejection fraction and renal function. FreeO2 will be recording respiratory rate, heart rate and SpO2 for the whole study duration. The respiratory rate will also be recorded manually and on the monitor. When patients will be receiving oxygen from FreeO2, the system will record the delivered flow ; with the usual mode, the staff will record the delivered FiO2. At the end of each intervention, hemodynamic measures will be taken : systolic, diastolic and median arterial blood pressure, systolic, diastolic and median pulmonary artery pressure and amine level.

*Initially, 15 patients were supposed to be included. After inclusion of those 15 patients, statistical analyses showed a lack of statistical power and a possibly significant difference in PaCO2, but only in half the patients. We thus submitted a protocol amendment to our institution's ethics committee to enlarge the sample size to 30 patients, which was accepted on July 13th, 2017.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • BMI > 30 kg/m2
  • SpO2 > or = 95 % before extubation
  • Procedure : coronary artery bypass

Exclusion criteria

  • Comorbidities : chronic obstructive pulmonary disease, cystic fibrosis, restrictive syndrome not associated with obesity (pulmonary fibrosis, neuromuscular junction disease, etc.)
  • Obstructive sleep apnea requiring a positive-pressure mask in the posteoperative period
  • FreeO2 device unavailable
  • Inclusion in another study that does not permit dual inclusion

Treatment and study plan

FreeO2

Other

Oxygen delivery automatically titrated by a closed-loop system that adjusts the oxygen flow based on the patient's real-time SpO2 and a programed SpO2 target of 90 %

Usual Care

Other

Oxygen delivery manually titrated by the nursing staff for a SpO2 target of > or = 95 %

Primary outcomes

  1. Difference in PaCO2

    Time frame: At 30 minutes (first intervention) and at 1h (second intervention)

    Difference in end-of-period PaCO2 on arterial blood gas

Secondary outcomes

  1. Difference in pH

    Time frame: At 30 minutes (first intervention) and at 1h (second intervention)

    Difference in end-of-period pH on arterial blood gas

  2. Difference in PaO2

    Time frame: At 30 minutes (first intervention) and at 1h (second intervention)

    Difference in end-of-period PaO2 on arterial blood gas

  3. Difference in percentage of time spent in hypoxemia (SpO2 < 88%)

    Time frame: In the first 30 minutes (first intervention) and between 30 min and 1h (second intervention)

    Difference in percentage of time spent in hypoxemia (SpO2 < 88%) between periods

  4. Difference in percentage of time spent in severe hypoxemia (SpO2 < 85 %)

    Time frame: In the first 30 minutes (first intervention) and between 30 min and 1h (second intervention)

    Difference in percentage of time spent in severe hypoxemia (SpO2 < 85 %) between periods

  5. Difference in percentage of time spent in hyperoxemia (SpO2 > 96 %)

    Time frame: In the first 30 minutes (first intervention) and between 30 min and 1h (second intervention)

    Difference in percentage of time spent in hyperoxemia (SpO2 > 96 %) between periods

  6. Difference in respiratory rate (manual and monitor)

    Time frame: At 0, 10, 20, 30, 40, 50 and 60 minutes

    Difference in respiratory rate (manual, monitor, FreeO2) between periods for each measuring technique (manual and monitor)

  7. Difference in mean heart rate

    Time frame: In the first 30 minutes and between 30 and 60 minutes

    Difference in mean heart rate, recorded continuously by FreeO2, between periods

  8. Difference in arterial blood pressure

    Time frame: At 0, 10, 20, 30, 40, 50 and 60 minutes

    Difference in arterial blood pressure (systolic, diastolic and mean) between periods

  9. Difference in pulmonary artery pressure

    Time frame: At 0, 10, 20, 30, 40, 50 and 60 minutes

    Difference in pulmonary artery pressure (systolic, diastolic and mean) between periods

  10. Difference in vasopressor dosage

    Time frame: At 0, 10, 20, 30, 40, 50 and 60 minutes

    Difference in vasopressor dosagel at different times between periods

  11. Difference in body temperature

    Time frame: At 0, 10, 20, 30, 40, 50 and 60 minutes

    Difference in body temperature at different times between periods

Sponsors and collaborators

Lead sponsor

Laval University

Other

Registry information

Official study title

Evaluation of the Risk of Hyperoxia-induced Hypercapnia in Obese Patients in a Cardiac Surgery Postoperative Setting

Important dates

Study start
2016
Primary completion
2018
Study completion
2018
First posted
Sep 28, 2016
Registry last updated
May 11, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.