JJVC Investigational Multifocal Toric Contact Lens manufactured in Senofilcon A (C3) material with UV blocker / HEV filter
DeviceTest Lens
NCT Number: NCT06377488
This will be an open-label, 3-visit, single-arm, dispensing clinical trial to evaluate visual acuity.
Looking for future studies?
Notify Me40 year–70 year
All sexes
Interventional
Not applicable
Dr. James Weber & Associates, PA - City Square Blvd, Jacksonville, Florida, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Potential subjects must satisfy all of the following criteria to be enrolled in the study:
Exclusion criteria
Potential subjects who meet any of the following criteria will be excluded from participating in the study:
The subject must not:
Test Lens
Time frame: 2-Week Follow-up
Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20. Data from hyperopes and myopes were combined for this outcome since logMAR scores between the two populations are similar.
Time frame: 2-Week Follow-up
Subjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE vision score for each sphere stratum (Hyperope and Myope) was reported.
Time frame: 15-minutes after lens insertion
Absolute rotation was assessed for each subject eye using a slit lamp 15-minutes after lens insertion. Acceptable absolute rotation was dichotomized into a binary response where Y=1 if absolute rotation was less than or equal to 10 degrees and Y=0 otherwise (absolute rotation greater than 10 degrees). The proportion of eyes with absolute rotation less than or equal to 10 degrees was report for each lens.
Time frame: 15-minutes after lens insertion
Rotational Stability was assessed for each subject eye using a slit lamp 15-minutes after lens insertion. Rotational Stability was dichotomized into a binary response where Y=1 if Rotational Stability was less than or equal to 5 degrees and Y=0 otherwise (Rotational Stability greater than 5 degrees). The proportion of eyes with Rotational Stability less than or equal to 5 degrees was report for each lens.
Time frame: Up to 2-Week Follow-up
Slit Lamp Findings (SLF) were assessed using a biomicroscope and was graded using the FDA grading scale (Grade: 0, 1,2, 3 and 4) with grade 0 represents the absence of findings and 1 to 4 representing successively worse findings (i.e. Grade 1 = trace, Grade 2 = Mild, Grade 3 = moderate and Grade 4 = severe). This was performed on each subject eye at every study visit (baseline, unscheduled visits and 1-week follow-up). The data was then dichotomized into two groups. Those with grade 3 or higher and those with grade 2 or lower. The proportion of eyes with SLF with grade 3 or higher was reported. Data from the hyperope and myopes group were combined for this outcome since the rate of SFLs grade 3+ is similar for these two populations.
Time frame: Up to 2-Week Follow-up
Contact lens fitting acceptance was assessed for each subject eye using a biomicroscope post lens insertion at the 1-week follow-up.
Lens fit was a binary variable where unacceptable lens fit=1 and acceptable lens fit=0. The proportion of eyes with unacceptable lens fit was reported. Data from the hyperope and myopes group were combined for this outcome since lens fitting characteristics are similar for these two populations.
Time frame: 2-Week Follow-up
Subjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE vision score for each sphere stratum (Hyperope and Myope) was reported.
Time frame: 2-Week Follow-up
Subjective comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE comfort scores for each sphere stratum (Hyperope and Myope) were reported.
Time frame: 2-Week Follow-up
Subjective handling was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE handling scores for each sphere stratum (Hyperope and Myope) were reported.
Time frame: Up to 1-Week Follow-up
The number of lenses to achieve the optimal pair for each subject was calculated as the original pair (2) plus all the required modifications to reach the optimal pair. In this study the minimum number of lenses per subject used was 2 where the maximum possible number of lenses used was 10. The data was dichotomized as Y=1 if the subject was able to achieve optimal lens pair in 4 lenses or lenses or less and 0 otherwise. A lens modification was performed if the subject reports unsatisfactory vision or was unable to obtain 20/30 distance visual acuity in both eyes. If the subject reported satisfactory vision with the lenses a modification was not required. However, based upon the investigator's findings on the measured visual acuity and/or over- refraction a modification may have been performed. Data for the hyperope and myope groups were combined for this endpoint since the number of subjects needed to optimize vision is independent of which group a subject belongs to.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details