Lumason
DrugLumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
Other names: SonoVue
NCT Number: NCT02552238
The purpose of this study was to assess the safety and efficacy of Lumason-enhanced dobutamine stress echo (DSE) in subjects having a suboptimal left ventricular endocardial border delineation (LV EBD) at rest and who were scheduled for coronary angiography.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 3
Cliniques Universitaires Saint-Luc Unité de Pathologie Cardio-Vasculaire / Cardiologie, Brussels, Belgium
The study was designed to assess the safety and efficacy of Lumason at improving the visualization of the LV EBD during pharmacologic stress echocardiography examinations and for detection or exclusion of the coronary artery disease (CAD). The study population consisted of adult subjects referred for pharmacological stress echocardiography and with suboptimal image quality during unenhanced ultrasound imaging at rest who had known or suspected CAD. Subjects enrolled in the study represented subjects who could benefit most from CEUS stress echocardiography.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
decompensated or inadequately controlled congestive heart failure (NYHA Class IV);
In addition, due to the use of Atropine in subjects who had not reached targeted heart rate with peak dobutamine infusion, subjects with the following were excluded:
Lumason (sulfur hexafluoride-type A microspheres) an ultrasound contrast agent was administered as 2 single 2-mL IV injections during rest and stress echocardiography
Other names: SonoVue
Time frame: Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography were performed
The diagnostic performance of the echocardiographic images was compared to the truth standard to determine sensitivity and specificity. A diagnosis of CAD was determined for both the echo images and truth standard (positive diagnosis for CAD is defined as >/= 50% stenosis of any vessel on coronary angiography or if no coronary angiography was performed the occurence of a cardiac event based on clinical information for up to 6 months post dose; otherwise the diagnosis was negative).
Results for sensitivity and specificity are reflected based on difference between contrast enhanced stress echo and unenhanced stress echo. Results for analysis of data based on majority assessment from the three off-site blinded readers are presented.
Sensitivity and specificity are the percentages of correctly diagnosed subjects by stress echo over the total positive and negative subjects according to the truth standard respectively.
Time frame: Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed
The percentage of subjects with suboptimal images (defined as >= 2 adjacent segments with inadequate LV EBD in any of the 3 apical views) at unenhanced stress echo converted to adequate (reduction of suboptimal segments in any of the 3 apical views) at contrast-enhanced stress echo
Time frame: Participants were followed until they had coronary angiography or up to 6 months post dose to collect clinical information on cardiac events if no coronary angiography was performed
Measured as the change in the total LV EBD score based on the 17 segments, from peak stress unenhanced vs. peak stress contrast-enhanced. Total LV EBD score ranges from 0 to 34 and higher score is better outcome.
Time frame: 72 hours post dose
To obtain safety data in subjects administered Lumason during echocardiography
Bracco Diagnostics, Inc
Industry
A Prospective Multicenter Phase III Clinical Evaluation of the Safety and Efficacy of Lumason™/SonoVue® in Subjects Undergoing Pharmacologic Stress Echocardiography With Dobutamine for the Diagnosis of Coronary Artery Disease
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03188705
Arterial Occlusive Diseases, Arteriosclerosis
Lancaster, Pennsylvania, United States
View Trial DetailsNCT07468955
Arterial Occlusive Diseases, Arteriosclerosis
Kütahya, Center, Turkey (Türkiye)
View Trial DetailsNCT06029517
Arterial Occlusive Diseases, Arteriosclerosis
Buffalo, New York, United States
View Trial DetailsNCT04058990
Arterial Occlusive Diseases, Arteriosclerosis
Kitakyushu, Fukuoka, Japan
View Trial Details