LinkCor Bioengineered Corneal Implant
DeviceIntrastromal implantation of a bioengineered corneal equivalent device
NCT Number: NCT04653922
This is a prospective, Phase I open-label safety study to evaluate the safety, feasibility and initial efficacy of a bioengineered corneal stromal substitute after implantation into the stroma of adults with advanced keratoconus. The bioengineered substitute and implantation technique may provide a less invasive treatment option for advanced keratoconus than current surgical approaches, that additionally does not rely on the limited availability of human donor corneal tissue.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
All India Institute of Medical Sciences, Dr. R. P. Centre for Ophthalmic Sciences, AIIMS,, New Delhi, India
This is a Phase I, open-label, non-randomized, non-controlled ongoing clinical case series in two participating centers in Indian and Iranian hospitals, to evaluate the safety and feasibility of minimally-invasive surgery of advanced keratoconus using a bioengineered corneal stromal substitute on a compassionate basis to alleviate blindness and low vision, due to the severely limited availability of human corneal donor tissue at these centers relative to the medical need. Patients fulfilling inclusion criteria are recruited consecutively and implanted intra-stromally with the bioengineered substitute, as a less invasive surgery than full-thickness or anterior lamellar corneal transplantation. In the first phase of the study, a total of 20 patients were recruited and safety and efficacy outcomes were evaluated in those having a minimum of 12 months of postoperative follow-up. In the second phase of the study (currently ongoing), up to 40 patients are being recruited, with one-year postoperative outcomes of all included patients to be evaluated as the final study endpoint. Primary safety and efficacy outcomes will be evaluated.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Intrastromal implantation of a bioengineered corneal equivalent device
Time frame: 6 months
The primary safety endpoint is defined such that a rejection leading to implant removal should occur in no more than 10% of implanted eyes. The implant rejection is defined as a clinical situation when the implanted eye has decreased central corneal clarity and decreased implant clarity, corneal vascularization inside of laser created pocket and inflammation.
Time frame: 6 months
The maximum and minimum corneal curvature (steepness) of each eye will be measured by a keratometer and reported in diopter (D) unit and represented as "K-value". The efficacy outcome is that more than 60% of the eyes should have a decrease in K-value at 6 months postoperatively.
Time frame: 6 months
Central corneal thickness (CCT) will be measured in microns and reported using a two-dimensional thickness map made by optical coherence tomography (OCT) and/or Pentacam topography. The efficacy outcome is that more than 60% of the eyes should have an increase in CCT at 6 months postoperatively.
Time frame: 6 months
Vision improvement equivalent of minimum one line in Snellen chart in uncorrected distance visual acuity (UDVA) or corrected distance visual acuity (CDVA).
LinkoCare Life Sciences AB
Industry
Evaluation of Safety and Efficacy of Intrastromal Implantation of LinkCor Bioengineered Corneal Implant for Management and Treatment of Keratoconus: a Prospective, Non-randomized, Non-controlled Case Series.
Acronym: LinkCor
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06818461
Corneal Diseases, Eye Diseases
Mohandessin, Giza Governorate, Egypt
View Trial DetailsNCT06100939
Corneal Diseases, Eye Diseases
Rowland Heights, California, United States
View Trial DetailsNCT06100952
Corneal Diseases, Eye Diseases
Scottsdale, Arizona, United States
View Trial DetailsNCT04418999
Allergy, Corneal Diseases
Chicago, Illinois, United States
View Trial Details