Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT04195568

Evaluation of Safety and Effectiveness of Stryker Surpass Evolve™ Flow Diverter System

The primary objective of this study is to evaluate the safety and effectiveness of the Surpass™ Evolve Flow Diverter System in the treatment of unruptured, wide-neck intracranial aneurysms measuring ≤ 12 mm and located on the ICA or its branches

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Liverpool Hospital, Liverpool, New South Wales, Australia

Loading trial locations.

About this study

The Surpass Evolve Flow Diverter System is indicated for the endovascular treatment of adults (age 18 or above) with unruptured saccular wide-neck or fusiform intracranial aneurysms ≤ 12 mm for treatment in vessel diameters between 1.75-5.0mm.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age is ≥ 18 and ≤ 80 years
  • Has a single unruptured target intracranial aneurysm (IA) with the following characteristics:
  • Is located on the internal carotid artery (ICA) or its branches.
  • Has a neck ≥ 4 mm, dome to neck ratio ≤ 2.0, or no discernible neck
  • Aneurysm size is ≤ 12 mm (saccular or fusiform configuration)
  • Has a parent vessel diameter ≥ 1.75 mm and ≤ 5.0 mm at both the proximal and distal segments where the implant will be placed
  • Has multiple increased risk factors for intracranial (IA) aneurysm rupture, including but not limited to, aneurysm morphology, smoking, hypertension, diabetes, age, prior and/or family history of rupture, and/or history of subarachnoid hemorrhage that may result in a benefit risk profile of endovascular treatment that outweighs the risks of intracranial aneurysm rupture during the subject's expected lifetime if left untreated.

Exclusion criteria

  • Has an extradural target aneurysm
  • Has a target aneurysm in the posterior circulation
  • Perforator or branch vessel, inclusive of the posterior communicating artery, arises from the target aneurysm body or neck (branches or arteries must arise or connect from the parent vessel separate from the aneurysm or neck to not be excluded from study)
  • Has a true bifurcation aneurysm, defined as an aneurysm (saccular or non-saccular) located at a point of vessel bifurcation
  • Target aneurysm is unsuitable for flow diverter treatment
  • Has vessel characteristics, such as severe tortuosity (cICA Type IV), stenosis (>70%), or morphology that would preclude safe endovascular access to the target aneurysm necessary for treatment with the study device
  • Received previous treatment of the target aneurysm or parent artery where it would interfere with the placement or proper apposition of the device
  • Has a medical contraindication to study or procedure related antiplatelet medications (aspirin, clopidogrel/Plavix, ticagrelor, and heparin), local or general anesthesia, or life-threatening allergy to contrast dye
  • Has a known severe allergy to nickel, chromium cobalt, tungsten or platinum.
  • Modified Rankin Score (mRS) assessment is ≥ 3 at preprocedure exam
  • Presence of unstable neurological deficit (i.e., worsening of clinical condition in the last 30 days)
  • Subarachnoid hemorrhage occurred within 30 days prior to enrollment
  • Major surgery (including previous intracranial implant) occurred within previous 30 days or is planned in the next 120 days after enrollment date
  • Has more than one IA that requires treatment within 12 months
  • Received previous intracranial implant associated with the symptomatic or vascular distribution within the past 12 weeks prior to treatment date
  • Chronic anticoagulation therapy is ongoing or known coagulopathy exists
  • Has other known serious concurrent medical conditions such as heart disease (e.g., unstable atrial fibrillation [with or without pacemaker], recent myocardial infarction [< 12 weeks ago], symptomatic congestive heart failure, or carotid stenosis), kidney failure [>2.0mg/dl serum creatinine], pulmonary disease, uncontrolled diabetes, progressive neurologic disorders, terminal cancer, vasculitis, high risk of ischemic stroke or recent stroke
  • Has acute life-threatening illness other than the neurological disease (e.g., acute kidney or heart failure) to be treated in this trial
  • Life expectancy is less than 5 years due to other illness or condition (in addition to an intracranial aneurysm)
  • Unable to complete study follow up due to dementia or psychiatric problem, substance abuse, or history of noncompliance with medical advice
  • Pregnancy at time of enrollment
  • Presence of intracranial mass (tumor, except meningioma, abscess, or other infection), non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm
  • Evidence of active infection at the time of treatment
  • Enrollment in another trial involving an investigational product that could confound the outcomes of this trial

Treatment and study plan

Surpass Evolve Flow Diverter System

Device

The Surpass Evolve Flow Diverter System is indicated for the endovascular treatment of adults (age 18 or above) with unruptured saccular wide-neck or fusiform intracranial aneurysms ≤12 mm.

Primary outcomes

  1. Primary Effectiveness Endpoint

    Time frame: 12 months (± 3 months) post procedure

    The primary effectiveness endpoint of this study is a composite of 100% occlusion (Raymond 1, complete occlusion) of the target aneurysm without significant parent artery stenosis (>50% stenosis), per independent core lab assessment of digital subtraction angiography (DSA) images acquired at 12 months (± 3 months) post-procedure, and with no target aneurysm retreatment.

  2. Primary Safety Endpoint

    Time frame: 12 Months (± 3 months) post procedure

    The primary safety endpoint of this study is neurologic death, or disabling stroke at 12 months as adjudicated by an independent Clinical Events Committee (CEC).

Secondary outcomes

  1. Secondary Safety Endpoints

    Time frame: 3 Year Follow-Up

    The secondary safety endpoints will be evaluated throughout the study, and are as follows:

    • Neurological death or major ipsilateral stroke as adjudicated by an independent Clinical Events Committee.
    • Stroke in the treated vascular territory as adjudicated by a Clinical Events Committee

Sponsors and collaborators

Lead sponsor

Stryker Neurovascular

Industry

Registry information

Official study title

EndoVascular Treatment Of Wide-Neck Aneurysms, an EvaLuation of Safety and EffectiVeness of Stryker Surpass Evolve™ Flow Diverter System

Acronym: EVOLVE

Important dates

Study start
2020
Primary completion
2025
Study completion
2028
First posted
Dec 12, 2019
Registry last updated
Apr 9, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.