Evaluation of Physical Changes in Single-Layer and Multi-Layer Clear Aligners

aim of the study: to evaluate and compare the surface roughness (Ra, Rq, Rz), Vickers microhardness (VHN), and thickness of single-layer and multi-layer clear aligner sheets.

material and methods: the study will be conducted on clear aligners fabricated from two commercial thermoplastic materials: single-layer (0.76 mm, ) and multi-layer (0.76 mm, ). Each material will be evaluated at three stages: before thermoforming, after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear.

Specimen Preparation For each group, specimens will be prepared at three stages: before thermoforming (T0), after thermoforming (T1), and after intraoral wear (T2). At T0, square-shaped specimens (approximately 5 × 5 mm) will be cut directly from the unused raw sheets. At T1 and T2, specimens of the same dimensions will be obtained from the mid-labial surface of the central incisor region of the thermoformed aligners, both immediately after thermoforming and after two weeks of intraoral wear. The full thickness of the material will be preserved in all specimens to ensure consistency across groups.

Outcomes:

Primary Outcome:

Surface Roughness (Ra):

Measured at three stages:

T0: Raw, unused sheet specimens (baseline) T1: After thermoforming on dental casts T2: After 2 weeks of intraoral use

Secondary Outcomes:

Hardness:

Measured at T0, T1, and T2. Tested using Vickers hardness method (ISO 6507 compliant).

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

16 year–24 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Mansoura university

Al Mansurah, Egypt

About this study

aim of the study: To evaluate and compare the surface roughness (Ra, Rq, Rz), Vickers microhardness (VHN), and thickness of single-layer and multi-layer clear aligner sheets at three stages: before thermoforming, after thermoforming, and following intraoral wear.

material and methods: This in vivo study will be conducted on clear aligners fabricated from two commercial thermoplastic materials: single-layer (0.76 mm, ) and multi-layer (0.76 mm, ). Each material will be evaluated at three stages: before thermoforming (raw sheet), after thermoforming on 3D-printed casts, and after 2 weeks of intraoral wear. At each stage, specimens will be retrieved and tested for changes in mechanical properties, specifically surface roughness and hardness.

Study Design Type: A prospective, randomized, controlled, two-arm parallel clinical study

Design Details: participants will be randomly assigned to one of two groups:

Group A:

Upper arch: Multi-layer clear aligners Lower arch: Multi-layer clear aligners

Group B:

Upper arch: Single-layer clear aligners Lower arch: Single-layer clear aligners Baseline control: Unused aligner sheets of both types to serve as reference for measurements.

Sample Size Calculation: Sample size calculation was calculated using G*Power v3.1.9.7, a paired t-test with an expected effect size dz = 0.65 (based on Bucci et al.), α error = 0.05, and power = 80% indicated a minimum of 19 subjects. To simplify group allocation and ensure adequate power, the sample size was rounded up to 20 patients (10 patients in each group: single-layer vs. multi-layer).

Ethical Considerations:

Informed Consent: All participants (or their legal guardians) will sign an informed.

Appliance Fabrication and Treatment Protocol

  • Digital impressions will be taken for all patients.
  • Treatment setup will be performed with standardized staging: maximum 0.25-0.3 mm linear movement or 2-3° rotation per stage.
  • Aligners will be fabricated by thermoforming using single and multilayer sheets (0.76 mm), cut and finished identically.

Specimen Preparation For each group, specimens will be prepared at three stages: before thermoforming (T0), after thermoforming (T1), and after intraoral wear (T2). At T0, square-shaped specimens (approximately 5 × 5 mm) will be cut directly from the unused raw sheets. At T1 and T2, specimens of the same dimensions will be obtained from the mid-labial surface of the central incisor region of the thermoformed aligners, both immediately after thermoforming and after two weeks of intraoral wear. The full thickness of the material will be preserved in all specimens to ensure consistency across groups.

Outcome Measures:

Primary Outcome:

Surface Roughness (Ra):

Measured at three stages:

T0: Raw, unused sheet specimens (baseline) T1: After thermoforming on dental casts T2: After 2 weeks of intraoral use Assessed using contact profilometry. Roughness defined as the arithmetic average surface deviation (Ra, in µm).

Secondary Outcomes:

Hardness:

Measured at T0, T1, and T2. Tested using Vickers hardness method (ISO 6507 compliant). Higher VHN values indicate greater resistance to indentation and deformation.

Thickness Change:

Measured at T0, T1, and T2. Evaluated using a digital micrometer or 3D scanning system. Calculated as the difference in thickness between the original sheet, thermoformed aligners, and post-use aligner

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Class I malocclusion with mild-moderate crowding (≤5 mm per arch).
  • Full permanent dentition (excluding third molars).
  • No restorations, caries, or attachments planned on the labial surface of upper/lower central incisors.

Exclusion criteria

  • Systemic disease affecting saliva.
  • Parafunctional habits (bruxism, nail-biting).
  • Smoking.
  • Pregnancy.
  • Previous orthodontic treatment within 1 year.

Treatment and study plan

Clear aligner

Device

Appliance Fabrication and Treatment Protocol

  • Digital impressions will be taken for all patients.
  • Treatment setup will be performed with standardized staging: maximum 0.25-0.3 mm linear movement or 2-3° rotation per stage.
  • Aligners will be fabricated by thermoforming using single and multilayer sheets (0.76 mm), cut and finished identically.

Primary outcomes

  1. surface roughness of clear aligner

    Time frame: 2 weeks

    evaluate and compare the surface roughness of single-layer and multi-layer clear aligner sheets at three stages: before thermoforming, after thermoforming, and following intraoral wear.

    Quantitative evaluation of the arithmetic mean surface roughness (Ra) using profilometer

Secondary outcomes

  1. microhardness of clear aligner

    Time frame: 2 weeks

    evaluate and compare the microhardness of single-layer and multi-layer clear aligner sheets at three stages: before thermoforming, after thermoforming, and following intraoral wear.

    Quantitative evaluation of surface microhardness using the Vickers hardness test.

  2. thickness change of clear aligner

    Time frame: 2 weeks

    evaluate and compare the thickness of single-layer and multi-layer clear aligner sheets at three stages: before thermoforming, after thermoforming, and following intraoral wear.

    Thickness will be measured using a calibrated digital caliper with an accuracy of ±0.01 mm

Sponsors and collaborators

Lead sponsor

Mansoura University

Other

Registry information

Official study title

Evaluation of Physical Changes in Single-Layer and Multi-Layer Clear Aligners After Thermoforming and Intraoral Wear

Important dates

Study start
2026
Primary completion
2027
Study completion
2027
First posted
Mar 4, 2026
Registry last updated
Mar 4, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.