Skip to main content
OpenTrials
Completed

NCT Number: NCT06491849

Evaluation of Peri-implant Conditions of Orthodontic Mini Implants

This observational study aims to evaluate the peri-implant conditions of mini implants placed during orthodontic treatment. Orthodontic mini implants are commonly used as temporary anchorage devices to prevent or reduce unwanted tooth movements during orthodontic treatment. The stability of these implants, both primary and secondary, is crucial for their success. Primary stability refers to the mechanical locking between the implant and bone immediately after placement, while secondary stability is achieved through bone remodeling around the implant over time.

Factors affecting the stability and success of mini implants include the patient's age, gender, cortical bone thickness and density, the site of implant placement, the presence of mobile surrounding tissue, implant dimensions, surface characteristics, and the magnitude and duration of applied orthodontic forces. Peri-implantitis, an inflammation around the implant, is a significant risk factor for implant failure and is influenced by oral hygiene and the quality of surrounding soft tissue.

This study will observe and analyze the peri-implant conditions in patients receiving orthodontic treatment with mini implants, focusing on the incidence of gingival/mucosal inflammation and other factors that may affect implant stability and success.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Altinbas University, Faculty of Dentistry

Istanbul, 34147, Turkey (Türkiye)

About this study

Study Title:

Evaluation of Peri-implant Conditions of Orthodontic Mini Implants

Objective:

The primary objective of this observational study is to evaluate the periodontal conditions surrounding orthodontic mini implants placed during orthodontic treatment. Additionally, the study aims to assess the impact of existing periodontal/peri-implant conditions on the stability of the mini implants.

Background:

Orthodontic mini screws/implants are commonly used as temporary anchorage devices to prevent or reduce unwanted tooth movements during orthodontic treatment. For these mini screws to function effectively as anchorage units, they must be resistant to the forces applied and remain stable at the site of placement throughout their use. Stability is classified into two types: primary stability, which is the mechanical locking between the implant and bone immediately after placement, and secondary stability, which results from bone remodeling around the implant over time. Both types of stability are crucial for the success of mini implants.

Several factors influence the stability and success of mini implants, including the patient's age, gender, cortical bone thickness and density, the site of implant placement, mobility of surrounding tissues, implant dimensions, surface characteristics, and the magnitude and duration of applied orthodontic forces. Peri-implantitis, an inflammation around the implant, is a significant risk factor for implant failure and is influenced by oral hygiene and the quality of surrounding soft tissues.

Hypothesis:

The hypothesis of this study is that the incidence of gingival/mucosal inflammation around the peri-implant/mini screw areas is high.

Methodology:

Patient Population:

The study will include patients treated at Altinbas University Dental Hospital's Departments of Periodontology and Orthodontics between March 2021 and March 2023. Patients must have at least one orthodontic mini implant placed and be systemically healthy. Patients with a history of prosthetic treatment or those taking medications that affect periodontal tissues (e.g., Cyclosporine-A, Calcium Channel Blockers, Phenytoin) will be excluded.

Clinical Assessments:

Primary Assessments:

Clinical periodontal/peri-implant measurements for the entire mouth and each mini implant/screw.

Bleeding on probing (yes/no), suppuration (yes/no), mucosal redness (erythema), plaque index (0-3), gingival index (0-3), probing depth (mm), clinical attachment loss (mm), width of keratinized mucosa (mm), peri-implant mucosal thickness (mm), and radiographic evaluation of the distance between the mini implant/screw and roots (mm).

Secondary Assessments:

Stability of the mini implants/screws measured using a torque gauge. Type of orthodontic force applied, method of placement (with or without a stent), surface characteristics, type (self-tapping/self-drilling), dimensions (diameter and length), duration of application, amount of force applied (<250 grams), and type of orthodontic force system (elastic/coil systems).

Statistical Analysis:

The study will utilize descriptive statistical methods to evaluate the collected data. Due to the original nature of the research, a power analysis could not be performed before the study.

Expected Outcomes:

The findings from this study are expected to highlight the importance of soft tissue health and maintenance during the planning, surgical placement, and post-operative phases of mini implant applications in orthodontics. Additionally, the study aims to elucidate the impact of existing oral hygiene on the stability and force continuity of mini implants in similar patient groups, thereby providing insights into the optimal frequency of periodontal maintenance for individuals with mini implant anchorage.

Study Location:

Altinbas University Dental Hospital, Zuhuratbaba Neighbourhood, Incirli St. No:11-A, 34147 Bakırköy, Istanbul, Turkey.

This detailed description provides a comprehensive overview of your study, outlining its objectives, background, methodology, and expected outcomes in a structured and academic manner.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Participants who have at least one orthodontic mini implant placed for anchorage during orthodontic treatment.
  • Systemically healthy individuals.
  • Participants without a history of prosthetic treatment.

Exclusion criteria

  • Individuals taking medications that can affect periodontal tissues (e.g., Cyclosporine-A, Calcium Channel Blockers, Phenytoin).
  • Individuals with a history of prosthetic treatment.
  • Individuals without orthodontic mini implants.

Treatment and study plan

Peri-implant Condition Evaluation

Other

This intervention involves a detailed clinical evaluation of peri-implant conditions in patients who have received orthodontic mini implants. The assessments include measuring periodontal parameters such as probing depth, bleeding on probing, mucosal redness, plaque index, gingival index, and implant stability. The evaluations are conducted at specified intervals during and after orthodontic anchorage treatment to monitor changes and ensure the health of peri-implant tissues.

Primary outcomes

  1. Gingival/Mucosal Inflammation

    Time frame: 3 months

    Measurement of gingival and mucosal inflammation around the orthodontic mini implants using clinical indices. Units of Measure:

    Gingival Index (GI) (0-3) Plaque Index (PI) (0-3)

  2. Probing Pocket/Mucosal Depth

    Time frame: 3 months

    Measurement of the depth of periodontal pockets or mucosal depth around the mini implants. Unit of Measure: Millimeters (mm)

  3. Clinical Attachment Loss (Gingival recession)

    Time frame: 3 months

    Measurement of the loss of attachment or gingival recession in the periodontal tissues and around the mini implants. Unit of Measure: Millimeters (mm)

  4. Width of Keratinized Mucosa

    Time frame: 3 months

    Measurement of the width of keratinized mucosa around the mini implants. Unit of Measure: Millimeters (mm)

  5. Thickness of Peri-Implant/Screw Mucosa

    Time frame: 3 months

    Measurement of the thickness of the mucosa around the mini implants. Unit of Measure: Thick/Thin

  6. Radiographic Evaluation

    Time frame: 3 months

    Measurement of the distance between the mini implant/screw and adjacent roots. Unit of Measure: Millimeters (mm)

  7. Bleeding on Probing

    Time frame: 3 months

    Assessment of the presence or absence of bleeding upon probing around the mini implants and teeth. Unit of Measure: Binary (Yes/No) and given as percentage by the site and full mouth.

  8. Mucosal redness (Erythema)

    Time frame: 3 months

    Assessment of the presence and degree of mucosal redness around the mini implants.

    Unit of Measure: Binary (Yes/No)

  9. Mucosal discomfort

    Time frame: 3 months

    Patient-reported discomfort in the area surrounding the mini implants. Unit of Measure: Binary (Yes/No)

Secondary outcomes

  1. Implant Stability

    Time frame: 3 months

    Assessment of the stability of the orthodontic mini implants using a torque gauge to measure insertion and removal torque values. Unit of Measure: Torque (Ncm)

Sponsors and collaborators

Lead sponsor

Dr. Mehmet Selim Yildiz

Other

Registry information

Official study title

Observational Study on the Peri-implant/Screw Conditions of Mini Implants Placed During Orthodontic Treatment

Important dates

Study start
2021
Primary completion
2023
Study completion
2023
First posted
Jul 9, 2024
Registry last updated
Jul 9, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.