CHU Brugmann
Brussels, 1020, Belgium
NCT Number: NCT03922178
The interpretation of perioperative measures of cardiac function during cardiac surgery is complicated. In particular, the evaluation of the diastolic compliance of the left ventricle. In addition, they are subject to variations induced by post-charge changes caused by the anesthesia, extracorporeal circulation (ECC) and the surgical procedure itself.
Left ventricular failure is frequently measured by alteration of LV contractile properties, and very rarely by alteration of LV compliance. However, both contractility (systolic) and relaxation (diastolic) parameters are important for the left ventricle to perform its function adequately. Left ventricular failure after cardiac surgery with extracorporeal circulation and cardiac arrest under cardioplegia protection is an important and frequently reported complication. The investigator's objectives are to characterize the diastolic hemodynamic mechanisms of this left ventricular failure and to identify predictors of this failure in the postoperative period.
The quantification of the systolic and diastolic functions of the left ventricle by ventricular pressure-volume curves is the technique of reference today, because it allows to determine parameters that are independent of the pre- and post-load conditions. Previous studies using the conductance catheter for the purpose of estimating left ventricular function perioperatively are rare and report conflicting results. In addition, they were mainly intended to measure the systolic function of the left ventricle. Only one reported the diastolic relaxation parameters evaluated by a conductance catheter. This study showed immediately after withdrawal of the extracorporeal circulation a significant alteration of the diastolic relaxation of the left ventricle, but was not interested in its early (kinetic) evolution peroperatively.
The investigator's experience shows that, in the quarter-hour following the weaning of the extracorporeal circulation, a decrease in filling pressures of the left ventricle concomitant with an increase in cardiac output is objectified. These observations are consistent with a significant improvement in left ventricle compliance, but have never been reported.
The objectives of this study are:
* To characterize the left ventricular diastolic failure after withdrawal of the extracorporeal circulation in coronary surgery. * To identify the kinetics of this early diastolic failure after withdrawal of the extracorporeal circulation.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Brussels, 1020, Belgium
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Hemodynamic data routinely collected and data collected by means of the placement of a Pressure/Volume Combination Catheter (Pressure/Volume Combination Catheter,Leycom,The Netherlands) will be collected simultaneously. The catheter will be placed and held in place as long as the patient is in a position to be assisted by extracorporeal circulation. This means that the placement of the catheter will follow the heparinization of the patient and the placement of the cannulas necessary for the realization of extracorporal circulation. It will be removed from the left ventricular cavity before removal of extra-corporal cannulas.
A complete transthoracic echocardiography will be performed the day before the surgical procedure, as per standard of care. It will establish the presence of the inclusion and exclusion criteria and evaluate the contractile function of the left ventricle. This will be done using a Philips IE33 echocardiograph (Koninklijke Philips Electronics N.V., Netherlands).
A transesophageal echocardiogram will be performed during the cardiac surgery, as per standard of care, using an Acuson Sequoia system (Siemens AG, Germany). It will facilitate the placement of the pressure/volume combination catheter and collect echographic data.
Time frame: Baseline (before extracorporeal circulation is switched on)
Pressure within the left ventricle after the atrial contraction, at the beginning of the ventricular contraction.
Time frame: 1 minute after extracorporeal circulation is switched on
Pressure within the left ventricle after the atrial contraction, at the beginning of the ventricular contraction.
Time frame: 1 minute after extracorporeal circulation is stopped
Pressure within the left ventricle after the atrial contraction, at the beginning of the ventricular contraction.
Time frame: 10 minutes after extracorporeal circulation is stopped
Pressure within the left ventricle after the atrial contraction, at the beginning of the ventricular contraction.
Time frame: 20 minutes after extracorporeal circulation is stopped
Pressure within the left ventricle after the atrial contraction, at the beginning of the ventricular contraction.
Time frame: Baseline (before extracorporeal circulation is switched on)
The pressure within the left ventricle following the completion of diastolic filling, just prior to systole.
Time frame: 1 minute after extracorporeal circulation is switched on
The pressure within the left ventricle following the completion of diastolic filling, just prior to systole.
Time frame: 1 minute after extracorporeal circulation is stopped
The pressure within the left ventricle following the completion of diastolic filling, just prior to systole.
Time frame: 10 minutes after extracorporeal circulation is stopped
The pressure within the left ventricle following the completion of diastolic filling, just prior to systole.
Time frame: 20 minutes after extracorporeal circulation is stopped
The pressure within the left ventricle following the completion of diastolic filling, just prior to systole.
Time frame: Baseline
At the end of systole, the ventricle contains a quantity of blood called 'telesystolic volume'.
Time frame: 1 minute after extracorporeal circulation is switched on
At the end of systole, the ventricle contains a quantity of blood called 'telesystolic volume'.
Time frame: 1 minute after extracorporeal circulation is stopped
At the end of systole, the ventricle contains a quantity of blood called 'telesystolic volume'.
Time frame: 10 minutes after extracorporeal circulation is stopped
At the end of systole, the ventricle contains a quantity of blood called 'telesystolic volume'.
Time frame: 20 minutes after extracorporeal circulation is stopped
At the end of systole, the ventricle contains a quantity of blood called 'telesystolic volume'.
Time frame: Baseline
At the end of diastole, the ventricle contains a quantity of blood called end-diastolic volume.
Time frame: 1 minute after extracorporeal circulation is switched on
At the end of diastole, the ventricle contains a quantity of blood called end-diastolic volume.
Time frame: 1 minute after extracorporeal circulation is stopped
At the end of diastole, the ventricle contains a quantity of blood called end-diastolic volume.
Time frame: 10 minutes after extracorporeal circulation is stopped
At the end of diastole, the ventricle contains a quantity of blood called end-diastolic volume.
Time frame: 20 minutes after extracorporeal circulation is stopped
At the end of diastole, the ventricle contains a quantity of blood called end-diastolic volume.
Time frame: Baseline
The ejection volume is the difference between systolic and diastolic volume. It represents the amount of blood ejected at each contraction by the ventricle.
Time frame: 1 minute after extracorporeal circulation is switched on
The ejection volume is the difference between systolic and diastolic volume. It represents the amount of blood ejected at each contraction by the ventricle.
Time frame: 1 minute after extracorporeal circulation is stopped
The ejection volume is the difference between systolic and diastolic volume. It represents the amount of blood ejected at each contraction by the ventricle.
Time frame: 10 minutes after extracorporeal circulation is stopped
The ejection volume is the difference between systolic and diastolic volume. It represents the amount of blood ejected at each contraction by the ventricle.
Time frame: 20 minutes after extracorporeal circulation is stopped
The ejection volume is the difference between systolic and diastolic volume. It represents the amount of blood ejected at each contraction by the ventricle.
Time frame: Baseline
Computed by the following formula: (dP/dt max)/P
Time frame: 1 minute after extracorporeal circulation is switched on
Computed by the following formula: (dP/dt max)/P
Time frame: 1 minute after extracorporeal circulation is stopped
Computed by the following formula: (dP/dt max)/P
Time frame: 10 minutes after extracorporeal circulation is stopped
Computed by the following formula: (dP/dt max)/P
Time frame: 20 minutes after extracorporeal circulation is stopped
Computed by the following formula: (dP/dt max)/P
Pierre Wauthy
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06822361
Coronary Surgery
Saint-Denis, Reunion
View Trial DetailsNCT01216150
Coronary Surgery, Hemorrhage
Paris, France
View Trial DetailsNCT07354841
Aortic Valve Surgery, Arterial Cannulation
Bari, BA, Italy
View Trial Details