Standard gluteus medius repair with Tapestry Biointegrative implant
DevicePatients will undergo standard gluteus medius repair utilizing augmentation.
NCT Number: NCT05492396
This is a prospective, single-center study design with enrollment of 15 subjects. The 15 subjects will all undergo standard gluteus medius repair that includes augmentation with the biointegrative implant. This is a small observational study. As such, we expect that the results from 15 subjects will give an adequate understanding of post surgical healing.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Observational
Jameson Crane Sports Medicine Institute, Columbus, Ohio, United States
Surgical gluteal tendon repair is a procedure performed regularly in operating rooms everywhere. This procedure is normally recommended to address gluteal tendon tears after nonoperative treatment options have been exhausted. However, less than satisfactory long-term outcomes can be common after open gluteal tendon repair. The augmentation of tendon repairs via various biointegrative implants is becoming more common in clinical practice, however very little, if any, of the literature details the healing after surgical intervention.
Biointegrative implants have been studied for the use of augmenting other tendon repairs, such as rotator cuff tears. Successful complete rotator cuff repairs augmented with a collagen-based implant have indicated that biointegrative implants are a safe option that may provide greater rates of healing and more positive long-term outcomes (Thon SG, 2019). Rates of healing and long-term outcomes when using a patch of this sort in other tendons such as the gluteal tendon in the hip show promise and demonstrate that there is a need for this area of study.
A 2016 study evaluated augmenting gluteus medius repair with a bioinductive implant, but the surgery was performed using endoscopic technique. There is no literature studying the healing of collagen-based implants for open gluteal tendon repairs. Although clinical outcomes show similar level of improvement for endoscopic and open gluteal tendon tear repair (Maslaris A, 2020), open repair technique with more anchors may be required for larger or more intricate tears.
This is a prospective, single-center study design with enrollment of 15 subjects. The 15 subjects will all undergo standard gluteus medius repair that includes augmentation with the biointegrative implant. This is a small observational study. As such, we expect that the results from 15 subjects will give an adequate understanding of post surgical healing.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients will undergo standard gluteus medius repair utilizing augmentation.
Time frame: 6 month
Graded as 'Intact/Attenuated/Disrupted'. Intact being the positive outcome, disrupted being the negative outcome.
Time frame: 6 month
Unit measured in centimeters
Time frame: 6 month
Hypoechoic signal present or absent. Present being the positive outcome, absent being the negative outcome
Time frame: Screening, 6 weeks, 3 month, 6 month, 12 months
Measures the functional status of the hip. Scores range from 0-100 where 100 means best functional outcome and least pain
Time frame: Screening, 6 weeks, 3 month, 6 month, 12 months
Assesses deficiencies with respect to outcome assessment of patients with hip disorders. Scores range from 0-100. Higher scores represent better quality of life.
Ohio State University
Other
Evaluation of Healing Following Open Gluteus Medius Repair Augmented With a Biointegrative Implant
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05038709
Arthritis, Hip Injuries
Chicago, Illinois, United States
View Trial DetailsNCT03158454
Hip Injuries, Wounds and Injuries
Aarhus, Denmark
View Trial DetailsNCT05762588
Ankle Injuries, Foot Injuries
Hyattsville, Maryland, United States
View Trial DetailsNCT05120063
Hip Injuries, Prosthesis User
View Trial Details